M

ICRONIX 

PC/104

 

 

P

OWER 

S

UPPLY

 

 

 

PV-5120,

 

22

 

&

 

24

 

 

P

OWER SUPPLY MODULE WITH 

UPS

 

 

AND UP TO 

3.84

 

MB

 

SSD

 

F

LASH

 

PC/104-M

ODULES

 

 

 

User Manual 

Installation Guide 

 

 

 

 

V

ERS

.

 

1.02 

 

 

 

 

 

 

 

 

 

                                               

D

OC

:

 M

5124

DM

.

DOC

 

Summary of Contents for MICRONIX PC/104 PV-5120

Page 1: ... 45 6615 3077 E mail support micro technic com Website www micro technic com MICRONIX PC 104 POWER SUPPLY PV 5120 22 24 POWER SUPPLY MODULE WITH UPS AND UP TO 3 84 MB SSD FLASH PC 104 MODULES User Manual Installation Guide VERS 1 02 DOC M5124DM DOC ...

Page 2: ...hutdown facility for battery discharge protection The automatic shut down procedure is initiated when both Mains failure and Low battery have been detected for 120 seconds At the end of this shut down time 5V will be removed from the system Low battery occurs when Vbat goes below 10 8V The CPU controlled shut down is initiated by a user program See Typical discharge charge cycle on page 8 Battery ...

Page 3: ...een LED indicating Mains 16V Battery charger Supported battery type 12V lead acid min 4AH Charging method Constant current constant voltage Charging current 400mA LED indicators Yellow LED indicating Battery full Red LED indicating Battery low UPS Alarm outputs Mains failure alarm interrupt Battery low alarm interrupt Interrupt support INT 5 7 9 10 11 12 15 programmable Automatic shut down 120 sec...

Page 4: ...capacity 0 No SSD 2 1 76 MB 4 3 84 MB A without UPS and battery charger S Stack through AVAILABLE MODELS Model no Description Type PV 5120 S PS with UPS Stack through PV 5122 S PS with UPS and 1 76 MB SSD Stack through PV 5124 S PS with UPS and 3 84 MB SSD Stack through PV 5120A S PS Stack through without UPS and battery charger ...

Page 5: ... GUIDE PRECAUTIONS TO ESD Please note that the Micronix PV modules must be handled with respect to ESD Electrostatic Discharge Electrostatic Discharge to the PV modules must be avoided Before removing the module from the protection bag the user must be discharged using a grounded wrist ribbon SCHEMATIC OUTLINE ...

Page 6: ...s no memory range PV 5122 PV5124 uses memory range D0000h D7FFFh Be sure that no other hardware in the system makes use of this memory range If your system BIOS set up has ROM BIOS shadowing functions you may enable shadowing in the D0000h D3FFFh range to improve flashdisk performance You should not enable shadowing in the D4000h D7FFFh range If your system BIOS only allows to enable disable shado...

Page 7: ...Users Manual Installation Guide PV SERIES Power supply module with UPS and SSD Flash Page 7 of 8 SCHEMATIC ...

Page 8: ...Users Manual Installation Guide PV series Power supply module with UPS and SSD Flash Page 8 of 8 UPS TIMING Typical discharge charge Short time dropout of mains ...