Micro Seven CD 15 Operator'S Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

OPERATOR’S MANUAL 

MICRO SEVEN, Inc. 

 

MODEL CD15 

CALLER-ID RECEIVER 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Micro Seven, Inc. 
P.O. Box 5597 
Beaverton, OR 
97006 
U.S.A. 
phone: 503-693-6982 
fax: 503-693-9742 

http://www.microseveninc.com

 

e-mail: [email protected] 

Summary of Contents for CD 15

Page 1: ...TOR S MANUAL MICRO SEVEN Inc MODEL CD15 CALLER ID RECEIVER Micro Seven Inc P O Box 5597 Beaverton OR 97006 U S A phone 503 693 6982 fax 503 693 9742 http www microseveninc com e mail support microseveninc com ...

Page 2: ...ed in any form without the written permission of Micro Seven Inc All requests for repairs should be directed to the factory There will be no warranty when the instrument is misused or when the factory seal on the instrument is broken Printed in U S A Specification and price change privileges are reserved ...

Page 3: ...r modes CD15 Control Register bit 1 position of bit 7 0 3 5 3 Telephone number only format CD15 Control Register bit 0 position of bit 7 0 3 5 4 How to read and write CD15 Control Register 3 5 5 Input signal attenuation CD15 Control Register bit 4 3 5 6 OFF HOOK CONTROL CD15 CONTROL REGISTER BIT 3 OHTIMEREG and WAITREG 3 6 CD15 Interface Register 3 6 1 Hardware handshake RTS and CTS 3 6 2 No hardw...

Page 4: ...tripped format or telephone number format The telephone number format outputs telephone numbers only Many RS232C data transfer handshake methods are provided including hardware handshake RTS CTS software handshake XON XOFF or no handshake modes Standard accessories include AC DC power adapter RS232C interface cable and operator s manual Communication error is displayed If there is a checksum error...

Page 5: ...or to indicate that caller ID data is available 2 Ring Signal red color to indicate that ring signal is received 3 Power Indicator to indicate that power is connected to CD15 Communication errors with incorrect checksum a word ERROR is output at RS232C port at the end of caller ID data Line characteristics Input impedance for caller ID FSK signals 1k ohm 5 Line Input Jacks USOC RJ11 C standard mod...

Page 6: ...Service is performed at the factory usually within 5 working days Micro Seven assumes no liability for loss of property money or human lives by application of CD15 caller ID receivers Standard accessories 117 V or 230V input AC DC Adapter 117V input unit is a standard 9 pin M F D sub cable and operator s manual Country of Origin Manufactured in United States of America ...

Page 7: ... Jack for connection to telephone line 2 CALLER ID DATA RECEIVED to indicate that CD15 has received caller ID data and it is available at the RS232C interface 3 J2 RJ11 C Line 2 Input Jack for connection to telephone sets 4 RING SIGNAL Indicator to indicate it receives ring signal 5 Power ON when the switch is in or OFF when the switch is out 6 Power LED on when the power is on 3 3 Rear Panel Desc...

Page 8: ...8 ...

Page 9: ...e is communication problem on the telephone line and CD15 did not receive the correct checksum in caller ID data a word ERROR is displayed at the end of caller ID data The description of CD15 Control and Interface registers are as follows 3 5 CD15 Control Register The CD15 Control Register one byte long is read or written by a special command string over RS232C interface The CD15 Control Register ...

Page 10: ...lay is turned on to establish off hook state to answer incoming ring signal The duration of the off hook relay is determined by programming OHTIMEREG as follows M54 n1 n2 where n1 n2 forms two digits hexadecimal number with increment of 100 ms For example M541D would programs three seconds period The above sequence of turning on relay is delayed by WAITREG as follows M53 n1 n2 where n1 n2 forms tw...

Page 11: ...3 6 4 Time delay between RS232C transmit When bit 5 of CD15 interface register is on 5 millisecond time delay is provided between transmission of characters 3 6 5 How to set up CD15 Interface Register The CD15 Interface Register is also a non volatile memory inside CD15 and it may be set by the following command M3D n1 n2 where n1 and n2 forms a 8 bit bytes When all bits in CD15 Interface Register...

Page 12: ... and found to comply with the limits for a Class A computing device pursuant to Sub part J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which cases the user at his own expense will be required to take whatever measur...