thermoMETER TIM 8 / thermoIMAGER TIM 40
9.4
Ethernet thermoMETER TIM 8
The thermoMETER TIM 8 has a direct Ethernet interface. The advantage is cable lengths of up to 100 m. For
example, a switch can be used to extend the distances.
The associated Ethernet cable (Order No.: TM-ETCx-TIM8) must be ordered separately. Ethernet is supported
from software version Rel. 3.2.3020.0 and firmware 3008.
Using the Ethernet connection, the device must be supplied with power. This can be done either via the inter-
nal PIF cable via the terminal block (12 - 30 V), via the stackable PIF (12 - 28 V, Order No.: TM-PIFCx-TIM8)
or via PoE (Power over Ethernet). For the PoE variant, a PoE adapter (Order No.: TM-ETPOEC1-TIM8) and a
PoE injector (Order No.:
TM-POE-TIM) or PoE switch (e.g. Netgear GS110TP) are also required.
Fig. 27 Possibilities of power supply for thermoMETER TIM 8 via Ethernet connection