Page 23
Optical Charts
thermoMETER TIM 8 / thermoIMAGER TIM 40
TIM 40
(382 x 288 px)
Focal
length
Minimum
distance
1
Distance to object (Measuring field in m, pixel in mm)
0,05
0,1
0,2
0,3
0,5
1
2
4
6
10
30
100
80 ° x 54 °
Wide angle
6 mm
0.2 m
HFOV
(m)
0.069
0.149
0.30
0.46
0.78
1.57
3.14
6.29
9.43
15.7
47.3
157.7
VFOV
(m)
0.047
0.098
0.20
0.30
0.51
1.01
2.03
4.06
6.10
10.2
30.5
101.7
IFOV
(mm)
0.2
0.3
0.6
0.9
1.5
3.0
6.0
12.0
18.1
30.1
90.3
300.9
Fig. 4 Table with examples (thermoIMAGER TIM 40) showing what spot sizes and pixel sizes will be reached in which distance
HFOV: Horizontal enlargement of the total measuring field at object level
VFOV: Vertical enlargement of the total measuring field at object level
IFOV: Size of the single pixel at object level
1) The accuracy of measurement can be outside of the specifications for distances below the defined minimum distance.