![MICRO-EPSILON scanCONTROL 25 100 Series Operating Instructions Manual Download Page 23](http://html1.mh-extra.com/html/micro-epsilon/scancontrol-25-100-series/scancontrol-25-100-series_operating-instructions-manual_1785285023.webp)
Page 23
Mounting and Installation
scanCONTROL 25xx
5.2
Connections
5.2.1
General
1 2
1 Ethernet socket
2 Multifunction socket (Power supply, IO)
Fig. 9 Output sockets arrangement
Designation
Sensor connector
Pin
Cable color
PCR3000-x
Notes
Connection view
+Ub
9
red
+ 11 V ... 30 V DC
(rated value 24 V); max. 500 mA
2
3
4
5
6
7
8
9
1
10
11
12
screw connector,
solder pin side
(cable)
GND
2
blue
0 V
+Laser on/off 3
white
optional
-Laser on/off
1
brown
RS422
12
red-blue
RS422
input or output
/RS422
11
gray-pink
In1
6
yellow
Switching input In1
GND-In1
4
green
Ground connection In1
In2
5
pink
Switching input In2
GND-In2
8
gray
Ground connection In2
In3
10
purple
Switching input In3
GND-In3
7
black
Ground connection In3
Screen
Housing
black
Not electrically connected to GND
Fig. 11 Assignment of the multifunction socket on scanCONTROL 25xx
GND: Galvanically isolated from IN1, 2, 3, RS422, Laser on/off
Laser on/off: Input galvanically isolated from GND, IN1…3, RS422
IN1, IN2, IN3, RS422: Inputs galvanically isolated from GND and Laser on/off