Control Commands
optoNCDT ILR 1183
8.2.12 Diagnostic Interval
The parameter Diagnostic Interval defines how often diagnostic reports are to be output. A diagnostic report
includes information about (but not limited to) the inner device temperature. For generation of diagnostic
data, a running distance measurement will be interrupted.
- Range of values: 0 ... 10000
- Time base: 100 ms.
If Diagnostic Interval is set to “0”, diagnostic data will only be output if there was an error.
Intervall » Diagnostics Intervall × 100 ms
Factory setting: Diagnostics Intervall = 10.
8.2.13 Average
The parameter Average allows a floating average value to be calculated from one to twenty measured single
values.
Factory setting: Average = 1
Calculation is based on this formula:
MW (k)
k=1
N
N
M =
av
∑
Fig. 1: Formula for the floating average value
Method:
Every new measuring value is added, the first (oldest) measuring value is taken out of the averaging.
Example with N = 7:
.... 0 1 2 3 4 5 6 7 8
gets to
2+3+4+5+6+7+8
7
Average value n
.... 1 2 3 4 5 6 7 8 9
gets to
3+4+5+6+7+8+9
7
Average value n +1
MW = Measuring value
N = Quantity
k
= Current index
M
av
= Average value