Seite 110
Anhang | ASCII Communication with Sensor
optoNCDT 1750
Examples:
a|b
// Use a or b
a b
// Both parameters are required
a [b [c]]
// Indefinite number of parameters: a, a b, or a b c
PASSWD <Old password> <New
password> <New password>
// In order to change the password, all parameters are re-
quired.
A 3.2.1.2
GETINFO, Sensor information
GETINFO
Controller data are queried. Output as per example below:
->GETINFO
Name:
ILD1750-10
//Model name sensor, sensor series
Serial:
17030001
// Serial number
Option:
001
//Option number of sensor
Article:
4120176
// Article number of sensor
Cable head:
Pigtail
Measuring range:
10.00mm
// Measuring range of the sensor
Version:
003.018.001
//Software version
Hardware-rev:
00
Boot version:
002.010
->