Page 30
Operation
optoCONTROL CLS1000
5.
Operation
5.1
Initial Operation
Install the optoCONTROL CLS1000 controller as per the installation instructions
.
Connect the controller to the downstream display or monitoring units and to the power supply.
The sensor may only be connected to peripherals when it does not carry power, that is, only when the
supply voltage has been switched off.
The green LED is illuminated after the supply voltage is activated.
5.2
Membrane Keys
Aside from the LED, the controller also has a display and membrane keyboard
via which the controller is operat-
ed.
The most important settings and controller operations can be activated via the keys and then displayed.
1
2
3
4
5
6
1
Field in display
Display
Meaning
Model
ON1
Illuminated
Q1 active
AU, AI, 2Q, OC
QN active
QN
ON2
Inactive, no display
AU, AI, OC, QN
Illuminated
Q2 active
2Q
TRG
Illuminated
Trigger active
Illuminated
Lock = active
Small numeric display
Switching value / current menu item
Large numeric display
Measurement value / measurement value
selection
Off
Concluding the
teach-in process
Flashing
Active teach-in process
2
6
Buttons for navigating the menu items and
changing values
3
LED green
Constant
supply voltage
Off
No supply voltage
4
Button for selecting/confirming menu item/
value.
Deactivate the key lock by pressing for
2 seconds
5
Button to undo the menu selection or go
back one menu level; to abort or discard