background image

1. 

Warnings

Connect the power supply and the display-/output device in accordance with the 
safety regulations for electrical equipment. The power supply must not exceed the 
specified limits.

 

> Danger of injury, damage or destruction of the sensor
Avoid shock and vibration to the sensor. Avoid continuous exposure to dust and spray 
on the sensor. Avoid exposure to aggressive materials (e. g. washing agent, penetrat-
ing liquids or similar) on the sensor.

 

> Damage to or destruction of the sensor
Read the detailed instruction manual before operating the sensor. You will find this 
manual on the provided CD or online at www.micro-epsilon.com.

2. 

Notes on CE Marking

The following apply to the gapCONTROL 27xx:  

 - EU directive 2014/30/EU
 - EU directive 2011/65/EU, „RoHS“ category 9

The sensor fulfills the specifications of the EMC requirements, if the instructions in the 
manual are followed.

3. 

Proper Environment

 - Protection class: 

IP 65 (Only applies to connected output plugs or  

    

protective caps)

 - Operating temperature:  0 to +50 °C (+32 to +122 °F), by free circulation of air
 - Storage temperature: 

-20 to +70 °C ( -4 to +158 °F)

 - Humidity:  

5 - 95 % (non condensing)

 - Vibration: 

DIN EN 600068-2-6 (sine shaped)

 - Mechanical shock: 

DIN EN 60068-2-29

4. 

Scope of Delivery of gapCONTROL 

27xx

 - 1 Sensor gapCONTROL 27xx with integrated controller
 - 1 power supply cable PC2700-4,5, length 4,5 m; ODU round connector and free 

cable ends

 - 1 gapCONTROL Setup Software CD with documentations
 - 1 Sensor inspection log / assembly instructions
 - 1 Bag of accessories with one ODU male connector 6-pin (RS 422) and two  

protective caps for ODU female connector (6- or 8-pin)

Assembly Instructions
gap

CONTROL 

2711/2761 (500)

Summary of Contents for gapCONTROL 2711

Page 1: ...U EU directive 2011 65 EU RoHS category 9 The sensor fulfills the specifications of the EMC requirements if the instructions in the manual are followed 3 Proper Environment Protection class IP 65 Only...

Page 2: ...required Mark the laser area recognizable and everlasting Laser Class 3B gapCONTROL 27xx sensors with a maximum laser power up to 20 mW are classified in Laser Class 3B IIIB When using lasers of 3B c...

Page 3: ...g Data transmission Red flashing Error code The state LED indicates different error conditions by flashing If no flashing occurs for several seconds no error has occurred Power supply Power Pin no Bel...

Page 4: ...nal accessories RS422 General 9 pin Sub D 1 1 RX1 CH1 2 2 RX1 CH1 3 5 GND1 5 3 TX2 CH2 9 4 TX2 CH2 1 6 GND2 5 The RS422 port can be used with either of the following configurations RS422 Loading of pr...

Page 5: ...pted IP address in the link local net 169 254 x x There is no collision testing effected This is the standard setting The sensor supports the DHCP protocol This setting is activated by default and has...

Page 6: ...System supply In 24 V 0 V OU Filter module 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP OU Fieldbus Coupler D D Sta D D D D D L1 L2...

Page 7: ...Connect the System supply out terminals of the OU Filter module to the System supply in terminals of the OU Fieldbus Coupler 0 V and 24 V Connect the system supply in of the OU Filter module to the p...

Page 8: ...ct the shield of the power supply cable to the PE protective earth conduc tor of the main power supply Close unused connection plugs with the provided protective caps Switch on the power supply 24 VDC...

Reviews: