background image

MICRO-EPSILON MESSTECHNIK GmbH & Co. KG
Koenigbacher Str. 15 · 94496 Ortenburg / Germany
Tel. +49 (0) 8542 / 168-0 · Fax +49 (0) 8542 / 168-90
[email protected] · www.micro-epsilon.com
Your local contact: 

www.micro-epsilon.com/contact/worldwide/

EDS-75-S
EDS-100-S/F
EDS-160-S/F
EDS-200-S/

EDS-220-Z
EDS-250-S/F

EDS-260-Z
EDS-300-S/F/Z
EDS-370-Z 
EDS-400-S/F/Z
EDS-500-S
EDS-630-S/F

Operating Instructions

indu

SENSOR

, EDS

Summary of Contents for EDS F Series

Page 1: ...Fax 49 0 8542 168 90 info micro epsilon com www micro epsilon com Your local contact www micro epsilon com contact worldwide EDS 75 S EDS 100 S F EDS 160 S F EDS 200 S F EDS 220 Z EDS 250 S F EDS 260...

Page 2: ...ng stroke sensors EDS series MICRO EPSILON MESSTECHNIK GmbH Co KG Koenigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon com www micro epsilon c...

Page 3: ...ata 10 3 Delivery 11 3 1 Unpacking Included in Delivery 11 3 2 Storage 11 4 Installation and Assembly 12 4 1 Precautions 12 4 2 Measuring Tube Guidance and Fastening 12 4 3 Sensor Mounting 14 4 3 1 ED...

Page 4: ...induSENSOR EDS 8 Liability for Material Defects 30 9 Decommissioning Disposal 30 Appendix 31...

Page 5: ...icates a tip for users 1 2 Warnings Connect the power supply according to the safety regulations for electrical equipment Risk of injury Damage to or destruction of the sensor The supply voltage must...

Page 6: ...lable to the responsible authori ties according to the EU Directives 1 4 Proper Use The sensors are designed for use in industrial and laboratory applications They are used for displacement measuremen...

Page 7: ...ide 450 bar Rear side 1 F series IP65 S series IP67 Z series IP40 Temperature range Storage 40 100 C 40 212 F Operation 40 85 C 40 185 F Humidity 5 95 non condensing Ambient pressure 450 bar front sid...

Page 8: ...without contact over a coil By inducing eddy currents in the aluminum tube energy is extracted from the coil thus detuning it The integrated electronics converts the tube position into a linear electr...

Page 9: ...ler is integrated in the sensor housing Long stroke displacement sensors are designed for measuring ranges from 75 to 630 mm Electrical connection 4 pin Amphenol connector type C164P compact EDS S mod...

Page 10: ...ies 7 pin M9 screw plug connection Binder axial also radial see accessories for connection cable F series Bayonet 5 pin screw plug connection radial see accessories for connection cable Z series Integ...

Page 11: ...urrent long stroke displacement sensors Sensor housing Carefully remove the components of the measuring system from the packaging and ensure that the goods are forwarded in such a way that no damage c...

Page 12: ...ns for the measuring tube can be found in the following figures see Fig 9 ff The measuring tube must not touch the sensor shaft when the piston is retracted Note the measuring tube position at zero po...

Page 13: ...EDS S Fig 4 Zero point of the measuring tube EDS F a Measuring range Dimension a 75 15 0 59 100 20 0 79 160 20 0 79 200 20 0 79 220 20 0 79 250 20 0 79 260 20 0 79 Fig 5 Zero point of the measuring tu...

Page 14: ...Appendix Optional Accessories and 6 cylin der head screws M5 x 10 Sealing is provided by a supplied O ring on the sensor shaft Displacement sensor O ring Piston Sensor shaft Cylinder Sensor rod 21HB M...

Page 15: ...ing see Fig 7 The bushing must be congruent with the connector for models with radial connector Fig 7 Mounting of an induSENSOR EDS S model Groove Suitable extractor Dismantling Use an suitable extrac...

Page 16: ...r EDS SA7 I model measuring range 75 100 160 200 250 300 Dimen sion Tolerance m A B 21f7 20 41 EDS xxx S Sx l 1 31 1 2 16 63 EDS xxx S Sx7 l 51 2 0 47 1 85 Dimensions in mm inches 1 Previous model no...

Page 17: ...OR EDS 13 0 51 A Fig 10 induSENSOR with radial connector EDS SR7 I model measuring range 75 2 95 100 3 94 160 6 29 200 7 87 250 9 84 300 11 81 A EDS xxx S Sx I 1 31 1 2 EDS xxx S Sx7 I 51 2 0 Dimensio...

Page 18: ...04 dia Fig 11 induSENSOR with axial connector EDS SA7 I model measuring range 400 500 630 Dimension Tolerance m A B 21f7 20 41 EDS xxx S Sx l 1 31 2 19 16 63 EDS xxx S Sx7 l 51 2 1 47 1 85 Measuring r...

Page 19: ...del induSENSOR EDS 13 0 51 A Fig 12 induSENSOR with radial connector EDS SR7 I model measuring range 400 15 74 500 19 69 630 24 80 A EDS xxx S Sx I 1 31 1 2 EDS xxx S Sx7 I 51 2 0 Dimensions in mm inc...

Page 20: ...head screws M8 x 6 Sealing is provided by a supplied O ring on the sensor shaft Sensor rod Cylinder Piston Sensor shaft Measuring tube O ring Displacement sensor 42F7 Cylinder head screw M8 Fig 13 Se...

Page 21: ...rod Measuring tube L D I d 100 3 93 140 5 51 10 0 39 140 5 51 16 0 63 160 6 29 200 7 87 10 0 39 200 7 78 16 0 63 200 7 87 240 9 45 10 0 39 240 9 45 16 0 63 250 9 84 290 11 42 10 0 39 290 11 42 16 0 6...

Page 22: ...fix it with a grub screw see Fig 15 Sealing is provided by a supplied O ring on the sensor shaft Guide the connection braids of the sensor in the cable shaft to the outside and connect them with the m...

Page 23: ...d Assembly EDS Z Model induSENSOR EDS Pressure chamber seal 1 O ring 44 12 x 2 62 Material Viton Mounting bore of the flange 48H8 dia Borehole surface Ra 0 8 Rmax 3 2 Dimension Tolerance 48H8 39 0 1 N...

Page 24: ...89 dia d D Fig 16 induSENSOR with axial braids EDS Z model measuring range 220 260 300 370 400 Measuring range Sensor rod Measuring tube L D I d 220 8 66 252 9 92 10 39 250 9 84 16 63 260 10 23 292 1...

Page 25: ...e Fig 17 Female thread in the extractor pipe M24 x 1 5 Proceeding 1 Open the plug connection on the intermediate plug 2 Loosen the grub screw 3 Unscrew the extraction tube on the sensor shaft and pull...

Page 26: ...ensor electronics The shield of the sen sor cable is connected to the housing of the cable socket 1 Power supply 18 30 VDC White 2 0 V Ground Brown 3 IOUT 4 20 mA 2 Green 4 Signal ground Yellow 5 Assi...

Page 27: ...able C705 x 1 A Power supply 18 30 VDC White B Power supply ground signal ground Brown Yellow C Signal 4 20 mA 2 Green D Shield housing E Not connected Gray Fig 21 Pin assignment for power supply and...

Page 28: ...and signal output View Connector pin side M12 x 1 4 pin Pin Assignment Color 1 Signal ground Brown 2 Power supply 18 30 VDC White 3 Signal 4 20 mA 1 Blue 4 Supply ground Black Fig 22 Pin assignment fo...

Page 29: ...es on measuring tube guiding during operation see 4 2 Improper measuring tube guidance can lead to increased wear and premature failure In the event of intervention by third parties warranty and any l...

Page 30: ...ties is not covered by the liability for material defects Repairs are carried out exclu sively by MICRO EPSILON Further claims can not be made Claims arising from the purchase contract remain unaffect...

Page 31: ...90 angled cable connector EDS S 7 series C703 5 U EDS connection cable 7 pin length 5 m for voltage output 1 5 VDC EDS S 7 series Measuring tube for EDS 75 S Spare tube Measuring tube for EDS 100 S Me...

Page 32: ...dix induSENSOR EDS 80 0 3 15 12 0 47 55 0 2 17 30 0 1 0 04 3 95 0 05 16 0 002 8 0 32 a b c d a 6 2 24 b 34 0 0 05 1 34 0 002 c 31 0 0 1 1 22 0 004 d 16 0 63 Fig 23 Mounting ring EDS S model dimensions...

Page 33: ...m EDS F series C705 15 EDS connection cable 5 pin length 15 m EDS F series Measuring tube for EDS 100 F Measuring tube for EDS 160 F Measuring tube for EDS 200 F Measuring tube for EDS 250 F Measuring...

Page 34: ...Koenigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon com www micro epsilon com Your local contact www micro epsilon com contact worldwide X9751051 C...

Reviews: