background image

Instruction Manual

thermo

METER

 CTVideo

CTVM-1L 
CTVM-1H 
CTVM-1H1
 

CTVM-2L 
CTVM-2H 
CTVM-2H1

CTVM-3L 
CTVM-3H 
CTVM-3H1 
CTVM-3H2 

CTVM-3H3

Summary of Contents for CTVM-1H

Page 1: ...Instruction Manual thermoMETER CTVideo CTVM 1L CTVM 1H CTVM 1H1 CTVM 2L CTVM 2H CTVM 2H1 CTVM 3L CTVM 3H CTVM 3H1 CTVM 3H2 CTVM 3H3...

Page 2: ...ESSTECHNIK GmbH Co KG K nigbacher Strasse 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon de www micro epsilon com Certified acc to DIN EN ISO 9001 2008 I...

Page 3: ...listed therein The EC declaration of conformity is kept available according to EC regulation article 10 by the authorities responsible at MICRO EPSILON MESSTECHNIK GmbH Co KG K nigbacher Stra e 15 944...

Page 4: ...modifications performed by third parties No other claims except as warranted are accepted The terms of the purchasing contract apply in full MICRO EPSILON will specifically not be responsible for even...

Page 5: ...ghting 39 Measurement Specifications CTVM 2 models 11 Error messages 40 Measurement Specifications CTVM 3 models 12 Software 41 Optics 14 Installation 41 Mechanical Installation 16 Communication Setti...

Page 6: ...sensor is made of stainless steel IP 65 NEMA 4 rating the sensor electronics is placed in a separate box made of die casting zinc Scope of Supply CTVideo sensor with connection cable and controller Mo...

Page 7: ...ersions Model Model code Measurement range spectral typical applications response CTVM 1 1L 1H 1H1 485 to 2200 C 1 m metals and ceramic surfaces CTVM 2 2L 2H 2H1 250 to 2000 C 1 6 m metals and ceramic...

Page 8: ...aging active Peak hold inactive Valley hold inactive 1L 1H 1H1 2L 2H 2H1 3L 3H Lower limit temperature range C 485 650 800 250 385 490 50 100 Upper limit temperature range C 1050 1800 2200 800 1600 20...

Page 9: ...range C 1000 1500 1800 Lower alarm limit C 350 550 750 normally closed Upper alarm limit C 600 1000 1200 normally open Lower limit signal output 0 V Upper limit signal output 5 V Temperature unit C A...

Page 10: ...sing Material stainless steel die casting zinc Dimensions 116 mm x 50 mm M48x1 5 89 mm x 70 mm x 30 mm Weight 600 g 420 g Cable length 3 m Standard 5 m 10 m Cable diameter 5 mm Ambient temperature cab...

Page 11: ...0 V thermocouple J or K or alarm output Signal source object temperature Alarm output Open collector output at Pin AL2 24 V 50 mA Output impedances mA max loop resistance 500 at 8 36 VDC mV min 100 K...

Page 12: ...of reading 1 C 3 Temperature resolution 0 1 C 3 Exposure time 90 signal 1 ms 4 Emissivity Gain 0 100 1 100 adjustable via programming keys or software Transmissivity 0 100 1 000 adjustable via program...

Page 13: ...1 of reading 1 C 3 Temperature resolution 0 1 C 3 Exposure time 90 signal 1 ms 4 Emissivity Gain 0 100 1 100 adjustable via programming keys or software Transmissivity 0 100 1 000 adjustable via prog...

Page 14: ...0 1 of reading 1 C 4 Temperature resolution 0 1 C 4 Exposure time 90 signal 1 ms 5 Emissivity Gain 0 100 1 100 adjustable via programming keys or software Transmissivity 0 100 1 000 adjustable via pr...

Page 15: ...1 C 4 Exposure time 90 signal 1 ms 5 Emissivity Gain 0 100 1 100 adjustable via programming keys or software Transmissivity 0 100 1 000 adjustable via programming keys or software Signal processing Av...

Page 16: ...front edge of the sensor The size of the measuring object and the optical resolution of the infrared thermometer determine the maximum distance between sensor and measuring object In order to prevent...

Page 17: ...4 7 7 3 10 7 16 7 33 3 measurement distance mm 200 300 450 700 1100 1600 2500 5000 1L 2L SF optics D S 150 1 spot size mm 0 6 0 8 1 0 1 2 1 4 1 7 measurement distance mm 90 120 150 180 210 250 1L 2L C...

Page 18: ...ic M48x1 5 thread and can be installed either directly via the sensor thread or with help of the supplied mounting nut standard and fixed mounting bracket standard to a mounting device available CTVid...

Page 19: ...thermoMETER CTVideo 17 CTVideo sensor High temperature version...

Page 20: ...ontroller Mounting bracket adjustable in one axis TM FB CTL standard scope of supply For an exact alignment of the sensor to the object please activate the integrated video and or crosshair laser sigh...

Page 21: ...in order to avoid reading errors These effects can be reduced by using an air purge collar Make sure to use oil free technically clean air only Air purge collar TM AP CTL Hose connection 6x8 mm Threa...

Page 22: ...thermoMETER CTVideo 20 Mounting Bracket Mounting bracket adjustable in two axes TM AB CTL This adjustable mounting bracket allows an adjustment of the sensor in two axis...

Page 23: ...up to 70 C without cooling For applications where the ambient temperature can reach higher values the usage of the optional water cooled housing is recommended operating temperature up to 175 C The se...

Page 24: ...pter for Controller With the rail mount adapter the CTVideo electronics can be mounted easily on a DIN rail TS35 according EN50022 Rail mount adapter TM RAIL CTL All accessories can be ordered using t...

Page 25: ...e CTVideo has a 12 pin connector which is integrated in the sensors backplane The connection to the controller is done by the blue sensor cable Cable lengths of 3 m 5 m and 10 m are available High tem...

Page 26: ...thermoMETER CTVideo 24 CTVideo Basic version CTVideo High temperature version...

Page 27: ...d Laser ORANGE Temperature probe sensor NTC BLUE Sensor ground PURPLE Sensor power YELLOW Detector signal Opened controller with terminal connections Power supply Please use a separate stabilized powe...

Page 28: ...out Extract about 4 mm of the wire isolation and tin the wire ends Place the pressing screw the rubber washer and the metal washers of the cable gland one after the other onto the prepared cable end S...

Page 29: ...round connections GND power supply outputs are connected with the ground of the electronics housing To avoid ground loops and related signal interferences in industrial environments it might be necess...

Page 30: ...KJ0 0OUD 0A1B A17U 93OZ block1 block2 block3 block4 block5 For entering the code please press the Up and Down key keep pressed and then the Mode key The display shows HCODE and then the 4 signs of the...

Page 31: ...e software allows the programming of output channel 1 as an alarm output Output signal Range Connection pin on CTVideo board Voltage 0 5 V OUT mV mA Voltage 0 10 V OUT mV mA Current 0 20 mA OUT mV mA...

Page 32: ...ard Functional Inputs The three functional inputs F1 F3 can be programmed with the software only F1 digital trigger a 0 V level on F1 resets the hold functions F2 analog external emissivity adjustment...

Page 33: ...into digital mode For this purpose the software is required Visual Alarms These alarms will cause a change of the color of the LCD display and will also change the status of the optional relays inter...

Page 34: ...outine for some seconds During this time the display will show INIT After this procedure the object temperature is shown in the display The display backlight color changes according to the alarm setti...

Page 35: ...V inactive 0 1 999 9 s V oo oo oo oo infinite u 0 0 Lower limit temperature range 0 C depending on model inactive at TCJ and TCK output n 500 0 Upper limit temperature range 500 C depending on model...

Page 36: ...an arithmetic algorithm will be performed to smoothen the signal The set time is the time constant This function can be combined with all other post processing functions The shortest value is 0 001 s...

Page 37: ...waits for ascending signals The definition of the algorithm is according to the peak hold algorithm inverted If the value is set to 0 0 the display will show function deactivated Signal graph with P...

Page 38: ...evel to the lower limit of the temperature range The adjustment range corresponds to the selected output mode e g 0 5 V 5 00 Setup of the Upper limit of the signal output This setting allows an assign...

Page 39: ...s shown the ambient temperature value will be taken from the head internal probe To return to XHEAD please press Up and Down together M 01 Setup of the Multidrop address In a RS485 network each sensor...

Page 40: ...e activated deactivated via the programming keys on the unit or via the software If the laser is activated a yellow LED will shine beside temperature display At ambient temperatures 50 C the laser wil...

Page 41: ...urement spot is indicated by a circle inside the video picture The size of this circle is equivalent to the IR spot size By turning the rotary button clockwise you will change the focus in direction f...

Page 42: ...re probe short circuit to GND 2x Controller temperature too low 4x Controller temperature too high 6x Controller temperature probe disconnected 8x Controller temperature probe short circuit to GND 2 D...

Page 43: ...instructions of the wizard until the installation is finished The installation wizard will place a launch icon on the desktop and in the start menu If you want to uninstall the software from your syst...

Page 44: ...Protocol All sensors of the CTVideo series are using a binary protocol Alternatively they can be switched to an ASCII protocol To get a fast communication the protocol has no additional overhead with...

Page 45: ...ommand Decimal 112 HEX 0x70 Data Answer byte 1 0x01 or 0x00 Parameter result 01 Data will not be written into the flash memory 00 Data will be written into the flash memory Complete command sequences...

Page 46: ...face temperature on the basis of the emitted infrared radiation from an object The most important feature of infrared thermometers is that they enable the user to measure objects contactless Consequen...

Page 47: ...results by interfering infrared radiation emitted by background objects flames heating systems chamottes To minimize measuring errors in such cases the handling should be performed very carefully and...

Page 48: ...f the colored surface CAUTION On all three methods the object temperature must be different from ambient temperature Characteristic Emissivities In case none of the methods mentioned above help to det...

Page 49: ...0 05 0 2 0 05 0 15 0 05 0 1 oxidized 0 2 0 8 0 2 0 9 0 5 0 8 0 4 0 8 Chrome 0 4 0 4 0 03 0 3 0 02 0 2 Gold 0 3 0 01 0 1 0 01 0 1 0 01 0 1 Haynes alloy 0 5 0 9 0 6 0 9 0 3 0 8 0 3 0 8 Inconel electro...

Page 50: ...4 0 1 0 3 0 1 0 15 0 05 0 15 oxidized 0 8 0 9 0 4 0 7 0 3 0 6 0 2 0 5 Platinum black 0 95 0 9 0 9 Silver 0 04 0 02 0 02 0 02 Steel polished plate 0 35 0 25 0 1 0 1 rustless 0 35 0 2 0 9 0 15 0 8 0 1...

Page 51: ...0 9 0 9 Ceramic 0 4 0 8 0 95 0 8 0 95 0 95 Concrete 0 65 0 9 0 9 0 95 Glass plate 0 2 0 98 0 85 melt 0 4 0 9 0 9 Grit 0 95 0 95 Gypsum 0 4 0 97 0 8 0 95 Ice 0 98 Limestone 0 4 0 98 0 98 Paint non alk...

Page 52: ...e of the average function is that fast temperature peaks which are caused by dynamic events are subjected to the same averaging time Therefore those peaks can only be seen with a delay on the signal o...

Page 53: ......

Page 54: ...N MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon com X9751322 A011074HDR X9751322 A01 MICRO EPSILON...

Reviews: