Page 11
Installation and Assembly
colorCONTROL MFA-7/-14/-21/-28
4.
Installation and Assembly
4.1
Installation and Mounting
i
Ensure careful handling during installation and operation.
Make sure that the sensors can move freely and that no sharp curves or corners are formed when
installing the colorCONTROL MFA-7/14/21/28.
> Damage to or destruction or failure of the sensor
> Distortion of test results
The smallest bending radius of the sensor (optical fiber) is 50 mm (permanent) or 10 mm (short-term).
i
Make sure that all the light from the LEDs is guided from the sensor to the color chip in the colorCONTROL MFA-XX.
6x 12.5
(6x .49)
28x
ø6.4
(28x .25 dia.)
23.3 (0.92)
35.25 (1.39)
83 (3.3)
42 (1.65)
ø2.7 (1.06 dia.)
42 (1.65)
134 (5.23)
100 (3.94)
17
(.67)
51 (2.01)
4x
ø4,4
(4x .17 dia.)
46.45 (1.83)
11.25 (.44)
M12x1
M12x1
11
(.43)
10.4
(.41)
22.7
(.89)
12
(.47)
12
(.47)
7
(.28)
Fig. 1 colorSENSOR MFA-28 dimensional drawing, dimensions in mm
Do not allow the end surfaces of the sensor to strike edges or surfaces. Reduced signal quality or
measuring device.
PS2020
230 VAC
PE
N
L
PS2020
PC
Offset
LED
W
orking
distance
Fig. 2 Typical measurement setup of MFA-XX controller with connected MFS sensor, power supply, and connection to PC