Page 5
Overview, Technical Data, Safety Instructions
thicknessCONTROL MTS 8202.LLT / 4350127.256
1.
Overview, Technical Data, Safety Instructions
1.1
Introduction
This documentation describes the non-contact thickness measurement of endless belt/
strips and plates. Please observe the following safety instructions when you use the sys-
tem. In addition to this information, it is important that you follow the instructions in the
individual chapters of the manual.
The system described in this manual complies with the requirements of the “DIN EN
60204.1 Electrical equipment of machines” standard and has been delivered in a fault-
free condition. In order to maintain this condition and ensure reliable usage, the operator
must observe the instructions and warnings on the system and in this manual.
It is necessary to contact Micro-Epsilon Messtechnik GmbH & Co. KG before the system
is modified or is combined in any way with parts and/or systems which have not been
approved by Micro-Epsilon or which are not described in this manual.
This manual is an important part of the system and must be read carefully before the
system is put into operation for the first time. This manual contains important information
concerning safety and maintenance. It must be kept at the system for this reason.
1.1.1 Validity
This manual is valid for MTS 8202.LLT, Item No. 4350127.256, manufactured by Mi-
cro-Epsilon Messtechnik GmbH & Co. KG. The manufacturer reserves the right to make
technical changes for the purpose of further development. In this case, an appendix to
this manual will be provided. The purchaser is required to check the version of the man-
ual and to include every addendum concerning technical innovations. The manufacturer
shall accept no liability for the correctness and completeness of the information stated in
this manual. The reader is requested to inform Micro-Epsilon Messtechnik GmbH & Co.
KG if any errors are found.
1.1.2 Software security
The following important information must be observed for all application software based
on thicknessCONTROL. The modification of hardware or software components in the
thicknessCONTROL system industrial PC is essentially not permitted. Exceptions must
be approved of in writing by Micro-Epsilon Messtechnik GmbH & Co. KG. The automat-
ic start of software components that do not originate from Micro-Epsilon Messtechnik
GmbH & Co. KG and which run in the background of the measurement process is not
permitted. When using virus scanners, the operator must be aware that the system will
be restricted and that malfunctions may occur with respect to real-time capabilities. Thus
the system cannot be reliably operated during this time. The integration of systems from
Micro-Epsilon Messtechnik GmbH & Co. KG into networks must only be performed by
qualified personnel. In doing so, the system operator is responsible for security on the
network.
Micro-Epsilon Messtechnik GmbH & Co. KG shall accept no claims arising from non-ob-
servance of these safety instructions.
Summary of Contents for 4350127.256
Page 1: ...thicknessCONTROL MTS 8202 LLT C frame Non contact thickness measurement Operating Instructions...
Page 10: ...Page 10 Overview Technical Data Safety Instructions thicknessCONTROL MTS 8202 LLT 4350127 256...
Page 26: ...Page 26 Installation and Commissioning Instructions thicknessCONTROL MTS 8202 LLT 4350127 256...
Page 56: ...Page 56 Declaration of Incorporation thicknessCONTROL MTS 8202 LLT 4350127 256...
Page 78: ...Operating Instructions scanCONTROL 29xx...
Page 83: ......
Page 119: ...Page 42 Operation of the Sensor with a PC scanCONTROL 29xx Fig 23 Predefined measuring fields...