background image

15 

©2021 Micro-Air Corp 

 

July 1, 2021, revision 1.8 

Appendix C: 9430-334 wiring 

 

Table 5 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5 shows the wiring functions used for this model thermostat. Option B must be selected in 

the settings’ switches menu. Only two heating zones are possible in this configuration. 

Yellow and green 

are used to turn on single stage furnaces for zones 1 and two respectively. This can be used in Aqua hot 
systems as well to turn on each of the two zones for heating. 

 

Two stage furnaces like certain suburban models use the orange and white wires to turn on the 

high furnace fan and high gas valve. This feature activates high furnace if the ambient temperature is 
more than four degrees below the set point. 

Original 

thermostat wire 

color 

Micro-Air harness 

color 

Function 

Factory harness color 

(Provided to write in your 

color) 

Purple 

Purple 

Signal 1 

 

Black 

Black 

Signal 2 

 

Green 

Green 

Zone 2 On 

 

White 

White 

Zone 1 High 

 

Blue 

Blue 

Ground in 

 

Red/White stripe 

Red/White stripe 

+12 VDC out 

 

Red 

Red 

+ 12 VDC in 

 

Blue/White stripe 

Blue/White stripe 

Ground out 

 

Orange 

Orange 

Zone 2 High 

 

Yellow 

Yellow 

Zone 1 On 

 

Summary of Contents for EasyTouch 355

Page 1: ...EasyTouch 355 Operating Manual Revision 1 8 ...

Page 2: ...ints 8 Schedule screen 9 Setting a change event 9 12 or 24 hour format 9 Setting the time 9 Enabling the schedule 9 Settings Screen 10 Gas Heat Override 11 Smart device application only features 11 Reset device 11 Calibrate Touchscreen 11 Check for updates 11 Notifications 12 Appendix A Installation Troubleshooting 13 WIFI Troubleshooting 13 No WIFI Icon 13 Red WIFI Icon 13 Appendix B Connecting r...

Page 3: ...for your application Installing the thermostat There are three steps to installing the thermostat First remove your old thermostat Next disconnect and reconnect the wiring Finally install the mounting pins to the wall and mount your new thermostat Removing the old thermostat The original thermostat is held to the wall with a backing plate that extends about 6 3mm from the wall The thermostat can b...

Page 4: ... wire these thermostats to the wiring if the manufacturer has directly wired the thermostat Match the original wiring colors to the provided EasyTouch connector colors to install the thermostat See Table 1 for details on the colors used with the thermostat and the function of the wires Note See Appendix C 9430 334 wiring for a different wiring table when replacing model number 9430 334 Table 1 Ori...

Page 5: ... Step 2 Screw in one screw and level the buttons so the display will be straight when installed Step 3 Screw in second screw making sure the two buttons remain level Step 4 Remove mounting tab before mounting on the wall Step 5 Aligning the buttons with the holes in the back of the display Press the display against the wall and gently slide the display down to lock it in place ...

Page 6: ...nt control boards for this feature Option B must be selected when replacing a thermostat with model number 9430 334 Press the Normal text in the available modes screen to change the text to Option B when replacing this thermostat See Appendix C 9430 334 wiring for more information on these systems Connecting remotely This thermostat may be operated remotely using either Bluetooth or WIFI Apps may ...

Page 7: ... Cooling Auto Cooling Auto Fan cycles with compressor or electric element Auto fan low N A Electric heat gas heat Fan turns on in low when heat is running Auto fan high N A Electric heat Gas heat Fan turns on in high when heat is running Fan off N A Gas heat Fan does not turn on when gas heating is active Note Auto fan speed changes with temperature More than 1 degree from set point will run the h...

Page 8: ... a cooling cycle is in process A white icon indicates no cycle is in process Away screen Heat and cool set points Away operation allows setting upper and lower limits for temperature with a non operating area or dead band in the middle This can be useful when setting a higher daytime cooling temperature and lower night time heating temperature It can also be used to control the temperature extreme...

Page 9: ...he temperature the system will try to achieve after the time that was set 12 or 24 hour format 2 Press the time in the upper right to change 12 and 24 hour time formats Setting the time 3 Time zone is set and saved whenever the thermostat connects using Bluetooth Time is set on power up through the internet connection or whenever a connection is made on either Bluetooth or WIFI Enabling the schedu...

Page 10: ...re with an offset This will only apply to zone 1 5 Schedule is used to change the set point automatically at a pre determined time See Schedule operation for more details 6 Bluetooth is used to reset the Bluetooth password This password is saved from your account password Only one account at a time may access the thermostat Reset the password whenever you change your account password 7 Brightness ...

Page 11: ...s without electric heating This is indicated by a red circle and line through the electric mode button When the furnace is actively overriding the electric heat a furnace symbol will appear at the top of the thermostat screen Smart device application only features Reset device This Bluetooth only feature allows resetting the display just as if you removed and restored power Calibrate Touchscreen I...

Page 12: ...e of operation with an 80 F maximum temperature set Notification will be sent for each degree it rises above the maximum temperature If temperature drops no notification will be sent unless the temperature exceeds the last maximum temperature again 82 in the example If the temperature drops two degrees below the set maximum 78 in the example it will again alert for each degree above the set maximu...

Page 13: ...e you are connecting to a 2 4 GHz network and not a 5GHz or 6GHz network Set the security to WPA2 and TKIP AES if you are having trouble The thermostat has a limit of 31 characters for the SSID and 50 for the password The number of devices limit for the network is not full The WIFI source is not out of range or metal partitions blocking the signal Reset the router to renew the DHCP lease If you ar...

Page 14: ...rmostat is to be added 1 Press Add on the top of the selection screen Apple or press the settings gear and Add Device Android 2 The second thermostat should be listed in the new selection window Select the device and enter a name for the device 3 Press OK and the screen will return to the settings menu Android or the selection screen Apple Android users should press the back button to get to the s...

Page 15: ...r heating Two stage furnaces like certain suburban models use the orange and white wires to turn on the high furnace fan and high gas valve This feature activates high furnace if the ambient temperature is more than four degrees below the set point Original thermostat wire color Micro Air harness color Function Factory harness color Provided to write in your color Purple Purple Signal 1 Black Blac...