Micro-Aide CSI-1 User Manual Download Page 1

M

ICRO

-A

IDE 

C

ORPORATION

 

Tel: 626-915-5502 

Fax: 626-331-9484 

E-mail: [email protected] 

685 Arrow Grand Circle   Covina, CA   91722

 

CSI-1 

C

HARGE 

S

TATUS 

I

NDICATOR

 

U

SER 

M

ANUAL

 

M

ICRO

-A

IDE

 

 

R

AIL 

S

IGNAL 

P

RODUCTS

 

E

VENT 

R

ECORDERS

 

S

PEED 

M

ONITORS

 

C

URRENT 

S

ENSORS

 

I

SOLATED 

M

ODEMS

 

B

ATTERY 

M

ONITORS

 

V

OLTAGE 

M

ONITORS

 

L

IGHT 

O

UT 

D

ETECTORS

 

C

LOCK 

S

YNCHRONIZERS

 

W

HISTLE 

D

ETECTORS

 

L

OCAL 

C

ONTROL 

P

ANELS

 

C

USTOM 

E

NGINEERING

 

Summary of Contents for CSI-1

Page 1: ... Grand Circle Covina CA 91722 CSI 1 CHARGE STATUS INDICATOR USER MANUAL MICRO AIDE RAIL SIGNAL PRODUCTS EVENT RECORDERS SPEED MONITORS CURRENT SENSORS ISOLATED MODEMS BATTERY MONITORS VOLTAGE MONITORS LIGHT OUT DETECTORS CLOCK SYNCHRONIZERS WHISTLE DETECTORS LOCAL CONTROL PANELS CUSTOM ENGINEERING ...

Page 2: ...m 8 to 30 Vdc The unit s operating temperature range extends from 40 C to 70 C The CSI 1 maintains a minimum isolation rating of 4 000 Vdc Its use is completely non intrusive Its electronic circuitry is housed in a rugged anodized aluminum chassis Figure 1 provides a three sided view of the CSI 1 Figure 2 illustrates the inside of the unit The last page of this document lists detailed specificatio...

Page 3: ...quired Note The CSI 1 is factory adjusted with a voltage limit value of 11 00 V Reinstall the cover plate after the voltage limit value has been set The CSI 1 is ready for use Reminder The adjustable DVM voltage reading should always be 1 10th of the desired voltage limit Caution Never adjust the second potentiometer It establishes the current limit value at 1 A and should not be changed Maintenan...

Page 4: ...4 Figure 1 Three sided view Current 4 1 2 0 1 625 2 125 Thumb screws 2 to remove cover Volts Alarm Amps N B NC Com NO CSI 1 M A ICRO IDE 3 0 562 Detachable connector 5 position screw down ...

Page 5: ...igure 2 Inside view Voltage adjust Pot 20 turn Reference test point green Voltage adjust test point red Warning Do not adjust Limit level equals 10 times DVM voltage reading Inside View with Cover Removed ...

Page 6: ...t 5 Vdc Maximum Operating Voltage 60 Vdc 125 Vac Maximum Switching Capacity 62 5 VA 30 W Service Life 5 million mechanical minimum 1 million electrical typical LED Indicators Alarm Red voltage and current are below respective limit values Voltage Green input is greater than limit value Current Green current exceeds 1 A Controls Internal Potentiometer 20 turn used to adjust voltage limit value Test...