Shop Measurements
The following information was gathered by measuring one machine. While the values recorded cannot serve
as “true specifications” they may help you recognize what normal looks like and give you some standard of
comparison.
Engine Vacuum
17.5-18 “HG (59-61kPa)-at warm idle. Measured at approximately 900 ft. elevation
LP Fuel Pressure
•
Primary - Approximately 3 psi (20 kPa)
•
Secondary - Approximately 1 psi (7 kPa)
Ignition Output
30 KV while cranking
Cam Sensor and Crank Sensor Oscilloscope Pattern
WaveStar : CKP and CMP Running Page: 1