Portable Electric Air Compressor Manual
5
maintenance instructions
Read the instruction manual before performing maintenance. The follow-
ing procedures must be performed when stopping the air compressor for
maintenance or service.
. Turn off air compressor.
2. Disconnect Power Cord from main power supply.
3. Open all drains.
4. Wait for the air compressor to cool before starting service.
WARNING
risK of bodilY inJurY!
never assume the air
compressor is safe to work
on just because it is not
operating. it could restart
at any time!
AC Ele. Maintenance Chart
maintenance cHart
procedure
dailY
WeeKlY
montHlY
200 Hours
Check pump oil level
X
Oil leak inspection
X
Drain condensation in air tank (s)
X
Inspect guards/covers
X
Check for unusual noise/vibration
X
Check for air leaks
X
Clean exterior of compressor
X
Inspect air filter
X
Inspect belt
X
Check safety relief valve
X
Change pump oil *
X
Replace air filter
X
*The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months,
whichever comes first.
Every two years, an Authorized Service Technician should check the check valve, intake valves and
delivery valves.