Your Voltec heater has been designed to produce warmth where and when you need it.
Radiant Convector (RC) heaters provide mostly radiant and varying proportions of convected heat.
Radiant panel and IPx4 radiated heaters produce mostly radiant heat.

Radiant

heat does not directly warm air but  warms objects and we therefore recommend that furniture etc. be kept one metre

clear from the front of the heater.

The heaters are supplied with a mains cord length which should be sufficient to allow connection to a
convenient 13A fused spur, or socket outlet via a 13 amp plug. (See fitting detail below).
Either must be fitted with the correctly rated fuse as detailed below;

© VOLTEC REF 02.2012

PRESS CORD BETWEEN GRIPS

BEFORE CONNECTING

CONDUCTORS TO TERMINALS.

General notes

Voltec panel heaters

Installation Guide

Voltec heating products are specifically designed to give you comfortable, controllable warmth when and where you need it. 

PLEASE READ THESE NOTES BEFORE INSTALLATION AND RETAIN FOR FUTURE REFERENCE.

IMPORTANT SAFETY ADVICE

1.

WARNING: THIS HEATER MUST BE EARTHED.

2.

This heater is for use as an indoor fixed appliance and is 

NOT FOR PORTABLE USE

.

3. DO NOT

use heater outdoors.

4. DO NOT

operate switches etc. with wet hands.

5.

Ensure that the heater is switched off when cleaning.

6. DO NOT

use where flammable gases or liquids are stored.

7.

This heater will be hot when in use. To avoid the possibility of
burns do not let bare skin touch hot surfaces. Momentary
contact should not cause any harm.

8. DO NOT

allow small children to play with the heater.

9.

To avoid over heating do not obstruct the air circulation around
the heater or allow curtains or furniture to touch or cover any
part of the casing.

10.

The installation of this heater should be carried out by an
electrician or competent person and be in strict accordance with
current IEE Wiring Regulations and all relevant Building
Regulations.

11.

Before connecting the heater, check that the supply voltage is

the same as that marked on the heater.

12.

If the flexible mains lead gets damaged 

DO NOT USE

the

heater, but have it removed (by a competent person) and
arrange to return it to the manufacturer for the fitting of a
replacement lead.

13.

There are no user serviceable parts inside the heater.

14.

Heaters must never be covered.

(a) 500 watts (5amp)
(b) 750 & 1000 watts (7amp)
(c) 1500 & 2000 watts (13amp)
Prepare lead for connection to a 13A plug as follows:

E

– Green & Yellow core, 

Length 41mm O/ All,
Strip off insulation to expose 8mm of bare wire.

L

– Brown core, 

Length 20mm O/ All,
Strip off insulation to expose 8mm of bare wire.

N

– Blue core,

Length 35mm O/ All,
Strip off insulation to expose 8mm of bare wire

.

WARNING!

WARNING THIS APPLIANCE MUST BE EARTHED

THE HEATER MUST NOT BE FIXED IMMEDIATELY BELOW A SOCKET OUTLET 

CONVECTION MODELS MUST NOT BE FITTED IN A BATHROOM 

REFER TO BATHROOM / SPLASH PROOF & 1PX4 MODELS