MGF 932299 User Manual Download Page 1

1

MGF

MGF

 srl –– Via Chico Mendes, 8 – 43058 Sorbolo Mezzani (PR) Italy – Tel. +39 0521-818301 Fax: +39 0521-818202

e-mail: [email protected] – 

www.mgftools.com

 – 

www.nebulizzare.com

Art. 932299 

FGAS Leak Detector

User Manual

Rev. 3 dated 26/08/2021

Summary of Contents for 932299

Page 1: ... Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 e mail info mgftools com www mgftools com www nebulizzare com Art 932299 FGAS Leak Detector User Manual Rev 3 dated 26 08 2021 ...

Page 2: ...ive corona halogen leak detector at present We integrate all our experience and customers feedback into this product in hope that it could provide our customer the best price performance and reliability The sensitive elements adopt the advanced and reliable corona refrigerant sensor which has great sensitivity and excellent repeatability the test program is controlled by the artificial intelligent...

Page 3: ...quipment Detect SF 6 in high voltage circuit breakers Detect most gases that contain chlorine Fluorine and Bromine halogen gases Detect cleaning agents used in dry cleaning applications such as perchloroethylene Operating Environment Temperature 0 C 50 C Humidity 95 RH non condensing Power supply two 2 C Alkaline Batteries supplied Sensor tip life under continuous operation more than 50 hours in n...

Page 4: ...ey Check the battery level The interface and keys of halogen leak detector please refer to Figure 2 Battery Installation WARNING To reduce the risk of igniting flammable gases in a closed atmosphere batteries must be replaced in an open area or closed space without flammable gas 1 See figure 3 Using a thumb to push open the battery door located at the bottom of the detector then to remove the door...

Page 5: ...l not interrupt detection 5 If alarm occurs before the sensing tip touches with the leakage source press Reset key to reset the current to 0 until there is no alarm then you could detect again 6 Press Mute key to close the alarm sound press it again to activate alarm sound loop operation 7 Press the BATTERY TEST key to check the battery level Halogen leak detector detecting method See Figure 4 1 V...

Page 6: ... Pinpointing the leak source needs to manually adjust the sensitivity and reset the detector by the technician You could follow recommendations below 1 In areas where the atmosphere is contaminated with halogen refrigerant press reset key to ignore the leak in the background Make sure not move the sensor tip away from the contaminated background while resetting the detector 2 In windy area the lea...

Page 7: ...ty Conformity Declaration Conformity Declaration MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy declares under its own responsibility that the FGAS Leak Detector art 932299 is in conformity with the following standards or standardized documents Safety Standards EN 61326 1 2013 Electromagnetic Compatibility 2014 30 EU MGF MGF srl Ing Maioli Francesco 7 MGF MGF srl Via Chico Mendes 8 ...

Page 8: ...at the minimum guaranteed sensitivity is respected This test is carried out by means of a sample leak calibrated according to the specifications of the EN14624 2012 standard Date Signature 8 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 e mail info mgftools com www mgftools com www nebulizzare com ...