6.2
Detailed connection overview
Figure 5 - Energy Monitor rear view
6.2.1
CAN-bus connectors details
The MG Energy Monitor communicates with and is powered by the connected system via CAN-bus.
This is a dedicated CAN-bus where only MG battery modules of the same type or other MG devices
may be connected.
6.2.1.1
Connector details
The CAN-bus connector of the Energy Monitor are circular M12 connectors with 5 positions and A-
coded keying.
Table 4 - Circular M12 connector with 5 positions A-coded details
Pin
Description
Connector view
1
Shield
2
V+
3
GND
4
CAN-H
5
CAN-L