background image

12

Controls and Connectors

European User Panel with

IEC 309 connector

U

ULL

C

C

U

ULL

®

®

LISTED

3K59

 COMMERCIAL

AUDIO SYSTEM

ATENCIÓN: ACCESO INTERNO
A PERSONAL TÉCNICO CALIFICA

ACHTUNG: GEHÄUSE NICH 
WARTUNG UND REPARATUR 
ELEKTROFACHKRÄFTE

ATTENTION: ENTRETIEN E 
INTERNES NE SONT AUTORISEE
TECHNIQUE QUALIFIÉ

UK WARNING:

 

THIS APPARAT

NO OPERATOR SERVICEABLE PART
SERVICING TO QUALIFIED PERSONN

WARNINGS:

This surface may reach high tempera

To ensure proper operation, allow a

clearance from this surface and adeq

To reduce the risk of electric shoc 

No operator serviceable parts insid 

qualified personnel.

To reduce the risk of fire or electric

this appliance to rain or moisture.

PU

SH

R

E

- C I R K

-I

T

 Earth / Chassis
 Earth / Chassis 

Input 

Loop 

Pin
2 +

3 +

!

1

1

2

3

1

3

2

8A RMS
20A Peak
95-125

~

50-60Hz
700W RMS MAX

Meyer Sound, 

Auto-Voltage Sele

Input Polarity

THIS PRODUCT MUST BE GROUNDED

PU

SH

R

E

- C I R K

-I

T

PUSH

Made by:Meyer Sound,Berkeley,Ca. U.S.A. 
European Office:
 
Meyer Sound Europe
14, Long Barn Lane,
Reading, Berkshire,
England RG2 7SZ

                             

Rear User Panel shown with the optional

Remote Monitoring System (RMS) panel

ATENCIÓN

: ACCESO INTERNO SOLO 

AUTORIZADO A PERSONAL TÉCNICO CALIFICADO

ACHTUNG

: GEHÄUSE NICHT ÖFFNEN WARTUNG 

UND REPARATUR NUR DURCH ELEKTROFACHKRÄFTE

ATTENTION

: ENTRETIEN ET REPARATIONS 

INTERNES NE SONT AUTORISEES QU'AU 

PERSONNEL TECHNIQUE QUALIFIÉ

UK WARNING

:

 

THIS APPARATUS MUST BE EARTHED. 

NO OPERATOR SERVICEABLE PARTS INSIDE. 
REFER SERVICING TO QUALIFIED PERSONNEL

WARNINGS:
THIS PRODUCT MUST BE GROUNDED

This surface may reach high temperatures while in use.

To ensure proper operation, allow at least 6 inches 

clearance from this surface and adequate ventilation.

To reduce the risk of electric shock do not remove cover.  

No operator serviceable parts inside.  

Refer servicing to qualified personnel.

To reduce the risk of fire or electric shock 

do not expose this appliance to rain or moisture.

!

Meyer Sound, Berkeley, CA. USA

1

2

3

1

3

2

Loop 

Input 

PUSH

Active / Speaker Fault

2 +

3 +

10K 

Balanced

Input Polarity 

Network

Service

Wink

Reset

Activity

R e m o t e     M o n i t o r i n g     S y s t e m

Earth / Chassis 

1

Case

220K 

ESD

PU

SH

R

E

- C I R K

-I

T

PU

SH

R

E

- C I R K

-I

T

Mains circuit
breakers

Signal input and

loop connectors

Power LED (green/red)

Input polarity switch

Tie-wrap anchor

Mains AC inlet

Remote Monitoring 
System panel 
(if RMS is installed)

SUB Limit

Driver Excursion Clamp
Sub Limit (red)

Exc. Clamp

PSW-2

95-125V

~

50-60Hz
1400W RMS MAX

   

208-235V

~

50-60Hz
1400W RMS MAX

Auto-Voltage Select

Meyer Sound Laboratories, Inc.

2832 San Pablo Avenue
Berkeley, California 94702
Telephone: 510 - 486 - 1166
FAX:

510 - 486 - 8356

E-mail: [email protected]
http://www.meyersound.com

Meyer Sound Germany
Gmbh

Carl Zeiss Strasse 13
56751 Polch, Germany
Telephone: 49.2654.9600.58
FAX:

49.2654.9600.59

Contact Information

Dimensions

Front

Side

Top

All units in inches

36.0"

21.25"

5.5"

14.0"

30.0"

13.0"

13.4"

22.0"

10.6"

13.2"

21.25"

30.3"

7.5°

Summary of Contents for PSW-2

Page 1: ...Operating Instructions PSW 2 Patents Pending Self Powered Subwoofer Copyright 1997 Meyer Sound Laboratories Inc All rights reserved Part 05 047 033 01 Rev A...

Page 2: ...C Humidity to 95 at 35 C Operating altitude to 4600 m 15 000 ft Nonoperating altitude to 6300 m 25 000 ft Environmental Specifications for Meyer Sound Electronics Products 1 0 kV Power Lines Pour ind...

Page 3: ...safety standards Voltage Requirements The PSW 2 operates safely and without audio disconti nuityiftheACvoltagestayswithineitheroftwooperating windows 85 134 V or 165 264 V at 50 or 60 Hz After applyin...

Page 4: ...a R t n e r r u C 2 W S P V 5 1 1 V 0 3 2 V 0 0 1 S M R s u o u n i t n o C x a M A 8 S M R A 4 S M R A 0 1 S M R S M R t s r u B x a M A 5 1 S M R A 8 S M R A 8 1 S M R t s r u B g n i r u D k a e P...

Page 5: ...n Make certain that the source equipment can drive the total load impedance presented by the paral leledinputcircuit Forexample sincetheinputimpedance of a single PSW 2 is 10 k cascading 20 PSW 2s pro...

Page 6: ...SW 2 uses a forced air cooling system with two fans to prevent the amplifiers from overheating The fans draw air in through ducts on the front of the cabinet over the heatsinks and out the rear of the...

Page 7: ...ld be done only by experienced professionals Configuration Placement and Polarity Designing a full range system requires an understanding of how subwoofers respond when grouped together how they inter...

Page 8: ...cy response caused by the acoustical environment and the placement and interaction of speakers We recommend using the Meyer LD 1A Line Driver to integrate different types of Meyer self powered speaker...

Page 9: ...re produced from speakers located close together The identical dimensions of the PSW 2 and MSL 4 allow them to be easily flown together The CH 1 Mid Hi output drives the MSL 4 with the Lo Cut filter i...

Page 10: ...tween adjacent loud speakers NOTE Since polarity reversal causes excessive driver excursion at high source levels use moderate levels for these tests Driver Polarity in the Same Loudspeaker A cabinet...

Page 11: ...nur von ausgebildetem Kundenienstpersonal durchgef hrt werden Para reducir el riesgo de descarga el ctrica desconecte de la red el altoparlante antes de instalar el cable de se alizaci ndeinterfazdela...

Page 12: ...WARNING THIS APPARATUS MUST BE EARTHED NO OPERATOR SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL WARNINGS THIS PRODUCT MUST BE GROUNDED This surface may reach high temperatures whil...