background image

9

650-P Subwoofers

MSL-4 Down-fills

Input

Mid-Hi

Output

Sub

Output

Input

Output

LD-1A

Delay

CP-10 EQ

CH 1

CH 3

Input

Output

CH 5

CP-10 EQ

Ch A

A

B

Ch B

MSL-6 Upper

MSL-6 Lower

CH 5 controls the MSL-4 down-fill system. Since the
main system is more powerful than the down-fill system
to project farther into the venue, the main system is
audible in the down-fill’s coverage area. To insure that
the systems combine properly in this area:

• Set the MSL-4 to the same polarity as the MSL-6 to

phase align the mid-hi frequencies.

• Use the CH 5 Array EQ filter to minimize the low-

mid rise caused by the MSL-4 array.

• Delay the down-fill to align it with the lower

MSL-6 system in their intersecting coverage area.

The polarity for the 650-P depends on the height and
distance of the measurement position from the flown and
subwoofer systems. The entire system should be measured,
phase-aligned, and equalized using the SIM System II
Sound Analyzer and CP-10 Parametric Equalizer.

Flown MSL-6, DS-2P, and MSL-4;
650-P on the Floor

The system from the previous example can be supple-
mented with a row of four DS-2Ps (or PSW-2s), sus-
pended below the lower MSL-6 array, to reinforce the
low frequencies. The MSL-4s are hung below the DS-2Ps
at 20

°

.

650-P Subwoofers

MSL-4 Down-fills

DS-2P

Input

Mid-Hi

Output

DS-2

Output

Sub

Output

Input

Output

LD-1A

Delay

CP-10 EQ

CH 1

CH 3

Input

Output

CH 5

CP-10 EQ

Ch A

A

B

Ch B

MSL-6 Upper 

MSL-6 Lower

The connections for this system are the same as the
previous example except that the CH1 DS-2 output
drives the DS-2P system with the DS-2 & Sub Crossover
switch in. The lower MSL-6 system should be delayed to
align with the upper MSL-6 system in the area in which
their coverage overlaps. The MSL-4 should also be de-
layed to align with the lower MSL-6 system.

Refer to the Operating Instructions for the MSL-4, 650-P,
and DS-2P (or PSW-2) to design arrays for those speakers.

The MSL-6, MSL-4, and DS-2P systems should be set to
the same polarity. The polarity for the 650-P depends on
the height and distance of the measurement position
from the flown and subwoofer systems.

The entire system should be measured, phase-aligned,
and equalized using the SIM System II Sound Analyzer
and CP-10 Parametric Equalizer.

Summary of Contents for MSL-6

Page 1: ...Operating Instructions MSL 6 Copyright 1997 Meyer Sound Laboratories Inc All rights reserved Part 05 053 026 01 Rev A Self Powered Loudspeaker System...

Page 2: ...C Nonoperating temp 40 C or 75 C Humidity to 95 at 35 C Operating altitude to 4600 m 15 000 ft Nonoperating altitude to 6300 m 25 000 ft Environmental Specifications for Meyer Sound Electronics Produ...

Page 3: ...ower is applied to the MSL 6 the Intelligent AC supply automatically selects the correct operating voltage allowing the MSL 6 to be used internationally withoutmanuallysettingvoltageswitches TheIntell...

Page 4: ...increase in cables which is used to select cables that conform to electrical code standards It is also used to select the rating for slow reacting thermal breakers The maximum burst RMS current is the...

Page 5: ...nd chassis Pins 2 and 3 carry the input as a differential signal their polarity can be reversed with the input polarity switch on the user panel If the switch is in the up position pin 2 is hot relati...

Page 6: ...igh limiter engages limiting the center as well as the outer two horns The high and low limiters function independently and do not affect the signal when the LEDs are inactive The MSL 6 performs withi...

Page 7: ...rolonged period in hot temperatures or direct sunlight accumulation of dust along the cooling path driver failure The secondary fans turn off when the temperature decreases to 68 C TROUBLESHOOTING NOT...

Page 8: ...Mid Hi DS 2 and Sub outputs channels 1 and 2 only each have their own gain control and mute switch POLARITY NOTE The polarity for Meyer self powered speakers may be reversed using the input polarity...

Page 9: ...or The system from the previous example can be supple mented with a row of four DS 2Ps or PSW 2s sus pended below the lower MSL 6 array to reinforce the low frequencies The MSL 4s are hung below the D...

Page 10: ...s that secure the high driver to the horn Hold the driver as the final nut is removed to prevent it from falling Twist the driver sideways and up down to remove it from the back of the cabinet Use a 3...

Page 11: ...e and overall level 4 Apply the same signal to the second speaker with the first speaker still connected The polarity is correct if the frequency response remains constant with a significant increase...

Page 12: ...pport Channel 11 Ga Steel Side Braces Resonance Damping Foam Bracing Fastened With 3 8 16 Grade B Steel Flathead Socket Screws 32 Total Pivoting Lift Ring 1500 lb Load Capacity 5 1 Safety Factor 12 pl...

Page 13: ...en nur von ausgebildetem Kundenienstpersonal durchgef hrt werden Para reducir el riesgo de descarga el ctrica desconecte de la red el altoparlante antes de instalar el cable de se alizaci ndeinterfazd...

Page 14: ...the optional Remote Monitoring System RMS panel ATENCI N ACCESO INTERNO SOLO AUTORIZADO A PERSONAL T CNICO CALIFICADO ACHTUNG GEH USE NICHT FFNEN WARTUNG UND REPARATUR NUR DURCH ELEKTROFACHKR FTE ATTE...

Reviews: