Measurement and System
Integration

Measurement and correction tools are required to
assemble a complete sound system, particularly when
the venue requires precise array design, delay systems,
or compensation for significant reverberation. We
recommend using the Meyer SIM® System II Sound
Analyzer 

and CP-10 Parametric Equalizer to

• assist the process of choosing and configuring

speakers;

• measure propagation delays between subsystems

to set the correct polarity and delay times;

• measure and equalize variations in frequency

response caused by the acoustical environment
and the placement and interaction of speakers.

We recommend using the Meyer LD-1A Line Driver to
integrate different types of Meyer self-powered speakers
into a complete system. The LD-1A has two channels
equipped to control a main system and six auxiliary
channels for down-fill, front-fill, and delay systems.
The LD-1A maintains signal integrity for long cable
paths and provides the following useful functions:

• The  Lo Cut switch activates a high-pass filter

(160 Hz, –12 dB/oct, Q = 0.8) that performs a
crossover function for the Mid-Hi output.

• The Array EQ switch activates a filter (6 dB cut

at 220 Hz, 0.6 octave bandwidth) to equalize
horizontal arrays of 3 to 5 MSL-4s.

• The DS-2 & Sub Crossover switch (channels 1 and

2 only) activates a crossover network optimized
for the DS-2P when used with the 650-P. With the
switch in, frequencies below 80 Hz are sent to the
Sub output (for the 650-P), and above 80 Hz to the
DS-2 output. When the 650-P is used without the
DS-2P, the switch should be out, which sends a
full-range signal to both the DS-2 and Sub outputs.

• The DS-2 

φ

 

and Sub 

φ 

switches (channels 1 and 2

only) toggle the polarity for the DS-2 and Sub
outputs.

• The Mid-HiDS-2, and Sub outputs (channels 1

and 2 only) each have their own gain control and
mute switch.

POLARITY NOTE: 

The polarity for Meyer self-powered

speakers may be reversed using the input polarity switch
on the user panel. The LD-1A also allows polarity reversal
with the 

DS-2 

φ

 

and 

Sub 

φ

 

switches for speakers

connected to the DS-2 and Sub outputs. When making
polarity decisions in applications that include the LD-1A,
check the state of all polarity switches.

Complete Systems

Meyer Speaker Types

The following Meyer speakers are mentioned in the
example applications.

MSL-4

Self-powered mid-hi speaker

DS-2P

Self-powered mid-bass speaker

PSW-2

Self-powered subwoofer

650-P

Self-powered subwoofer

The Meyer self-powered speakers listed above have a
loop 

connection to send the input signal to another

speaker. Full-range signals can be applied to all Meyer
self-powered subwoofers because they have built-in
active crossovers that filter mid-hi frequencies.

Flown MSL-6 and MSL-4;
650-P on the Floor

This example shows a large concert system controlled by
the LD-1A consisting of two rows of two MSL-6s (lower
row at 10

°

 to the top row), one row of two MSL-4s with

a 30

°

 horizontal splay angle (hung below lower MSL-6 at

20

°

), and 650-Ps on the floor. The diagram on the next

page displays connections for half of a complete system;
channels 2, 4, and 6 can be used with identical connections
to create the other half.

The CH 1 Mid-Hi and CH 3 outputs drive the upper and
lower MSL-6 arrays, respectively. Since the coverage
areas of the upper and lower MSL-6 arrays intersect to
some degree, CH 3 is delayed to phase align the upper
and lower systems. The Lo Cut switches for the CH 1
Mid-Hi and CH 3 outputs should be in. The number of
MSL-6s for each row depends on the horizontal coverage
required by the system; each tight-packed unit adds
30

°

. Refer to the MSL-4 and 650-P Operating Instructions

to design arrays for those speakers.

Summary of Contents for MSL-6

Page 1: ...Operating Instructions MSL 6 Copyright 1997 Meyer Sound Laboratories Inc All rights reserved Part 05 053 026 01 Rev A Self Powered Loudspeaker System...

Page 2: ...C Nonoperating temp 40 C or 75 C Humidity to 95 at 35 C Operating altitude to 4600 m 15 000 ft Nonoperating altitude to 6300 m 25 000 ft Environmental Specifications for Meyer Sound Electronics Produ...

Page 3: ...ower is applied to the MSL 6 the Intelligent AC supply automatically selects the correct operating voltage allowing the MSL 6 to be used internationally withoutmanuallysettingvoltageswitches TheIntell...

Page 4: ...increase in cables which is used to select cables that conform to electrical code standards It is also used to select the rating for slow reacting thermal breakers The maximum burst RMS current is the...

Page 5: ...nd chassis Pins 2 and 3 carry the input as a differential signal their polarity can be reversed with the input polarity switch on the user panel If the switch is in the up position pin 2 is hot relati...

Page 6: ...igh limiter engages limiting the center as well as the outer two horns The high and low limiters function independently and do not affect the signal when the LEDs are inactive The MSL 6 performs withi...

Page 7: ...rolonged period in hot temperatures or direct sunlight accumulation of dust along the cooling path driver failure The secondary fans turn off when the temperature decreases to 68 C TROUBLESHOOTING NOT...

Page 8: ...Mid Hi DS 2 and Sub outputs channels 1 and 2 only each have their own gain control and mute switch POLARITY NOTE The polarity for Meyer self powered speakers may be reversed using the input polarity...

Page 9: ...or The system from the previous example can be supple mented with a row of four DS 2Ps or PSW 2s sus pended below the lower MSL 6 array to reinforce the low frequencies The MSL 4s are hung below the D...

Page 10: ...s that secure the high driver to the horn Hold the driver as the final nut is removed to prevent it from falling Twist the driver sideways and up down to remove it from the back of the cabinet Use a 3...

Page 11: ...e and overall level 4 Apply the same signal to the second speaker with the first speaker still connected The polarity is correct if the frequency response remains constant with a significant increase...

Page 12: ...pport Channel 11 Ga Steel Side Braces Resonance Damping Foam Bracing Fastened With 3 8 16 Grade B Steel Flathead Socket Screws 32 Total Pivoting Lift Ring 1500 lb Load Capacity 5 1 Safety Factor 12 pl...

Page 13: ...en nur von ausgebildetem Kundenienstpersonal durchgef hrt werden Para reducir el riesgo de descarga el ctrica desconecte de la red el altoparlante antes de instalar el cable de se alizaci ndeinterfazd...

Page 14: ...the optional Remote Monitoring System RMS panel ATENCI N ACCESO INTERNO SOLO AUTORIZADO A PERSONAL T CNICO CALIFICADO ACHTUNG GEH USE NICHT FFNEN WARTUNG UND REPARATUR NUR DURCH ELEKTROFACHKR FTE ATTE...

Reviews: