background image

1

INTRODUCTION

These operating instructions provide important information 
about the form, features, function, and specifications of the 
MJF-212A

 high-power stage monitor. 

Chapter 1: Introducing mJf-212A

 provides a general 

description of MJF-212A and its capabilities and 
functionality.

Chapter 2:

 

Power Requirements 

discusses power 

distribution and voltage and current requirements, as well 
as electrical safety issues.

Chapter 3: Amplification and Audio

 will help you 

understand and harness the power of the MJF-212A 
amplifier. Amplifier specifications, connectivity, limiting, and 
the cooling system are all covered.

Chapter 4:

 

RmS™ Remote monitoring System

 introduces 

the optional RMS communication module that can be 
installed in the MJF-212A amplifier to make use of Meyer 
Sound’s RMS remote monitoring system.

Appendix A:

 

Optional VEAm multipin Connector 

includes information on the optional factory-installed VEAM 
Connector.

Appendix b:

 

Specifications and Dimensional Drawings

 

provides detailed acoustic and electrical specifications for 
the MJF-212A monitor, along with detailed dimensional 
drawings.

HOw TO USE THIS mANUAl

As you read this manual, you’ll find figures and diagrams 
to help you understand and visualize what you’re reading. 
You’ll also find icons that flag important information or warn 
you against improper or potentially harmful activities. These 
icons include:

         

A

 NOTE 

identifies an important piece of 

information relating to the topic under 

discussion.

TIP 

offers a helpful tip relevant to the topic 

at hand. 

CAUTION

 gives notice that an action can 

have serious consequences and could cause 

harm to equipment or personnel, delays, or other 
problems.

Information and specifications are applicable as of the date 
of this printing. Updates and supplementary information are 
posted on the Meyer Sound website at:

     http://www.meyersound.com

You can contact Meyer Sound Technical Support at:

     Tel: +1 510 486.1166

     Fax: +1 510 486.8356

     E-mail: [email protected]

INTRODUCTION

Summary of Contents for MJF-212A

Page 1: ...OPERATING INSTRUCTIONS ULTRAseries MJF 212A High Power Stage Monitor Keep these important operating instructions Check www meyersound com for updates...

Page 2: ...to 4600 m 15 000ft Non operating altitude to 6300 m 25 000ft Shock 30 g 11 msec half sine on each of 6 sides Vibration 10 Hz to 55 Hz 0 010 peak to peak excursion 2007 Meyer Sound All rights reserved...

Page 3: ...d by Meyer Sound or sold with the loudspeaker Handles are for carrying only 13 Unplug this loudspeaker during lightning storms or when unused for long periods of time 14 Refer all servicing to qualifi...

Page 4: ...ages auf ein Minimum zu reduzieren den Lautsprecher vom Stromnetz trennen bevor ggf ein Audio Schnittstellensign alkabel angeschlossen wird Das Netzkabel erst nach Herstellung aller Signalverbindungen...

Page 5: ...Electrical Safety Issues 8 CHAPTER 3 Amplification and Audio 9 Audio Input 9 Amplification and Protection Circuitry 9 MJF 212A Interconnections 10 Cabling 10 The Limiting System 10 Low Frequency Limi...

Page 6: ...vi...

Page 7: ...tory installed VEAM Connector Appendix B Specifications and Dimensional Drawings provides detailed acoustic and electrical specifications for the MJF 212A monitor along with detailed dimensional drawi...

Page 8: ...INTRODUCTION...

Page 9: ...m concerts as well as corporate AV applications and clubs The MJF 212A produces a peak output of 139 dB SPL with exceptionally flat phase and frequency response The cabinet is constructed from premium...

Page 10: ...sing package also incorporates Meyer Sound s Intelligent AC power supply which automatically adjusts for common line voltage worldwide and provides both soft turn on and transient protection The MJF 2...

Page 11: ...distribution system with the load between loudspeakers distributed among the three phases and all of the loudspeakers connected to common neutral and earth ground points Figure 2 1 A sample AC power...

Page 12: ...For units shipped with the VEAM all in one multipin connector please refer to Appendix A for AC Power pin out Caution When creating AC cables and distribution systems it is important to preserve AC l...

Page 13: ...o either low or high voltage its power supply automatically turns on again after three seconds if the voltage has returned to either normal operating window If the MJF 212A stage monitor does not turn...

Page 14: ...hat the circuit breakers on the monitor s user panel trip the white center buttons pop out disconnect the AC power cable Do not reset the breakers with the AC connected Contact Meyer Sound for repair...

Page 15: ...loudspeaker If the noise stops most likely the problem is not with the loudspeaker Check the audio cable source and AC power to pinpoint the problem Audio signals can be daisy chained using the Loop o...

Page 16: ...or s left and right 12 inch cone drivers are powered by separate amplifier channels each with a detector but routed to one limiter The lower limit LED on the user panel indicates limiting activity for...

Page 17: ...he temperature of the heatsink reaches 75 C 167 F the On Temp LED on the rear panel turns from green On to red Temp The unit continues to operate normally even if the On Temp LED is red but this is an...

Page 18: ...12 CHAPTER 3...

Page 19: ...his information is permanently retained on each RMS communication board and in the computer RMS database until you modify it Loudspeaker View labels can be modified at any time allowing you to customi...

Page 20: ...e Service Button the card will be decommissioned from the network and the red Service LED will blink Activity LED Green When the loudspeaker has been commissioned the Activity LED will flash continuou...

Page 21: ...neutral blue Figure A 1 VEAM multipin connector power pin out For complete wiring conventions and pin outs for AC audio and RMS connections please refer to the Meyer Sound document VEAM Cable Wiring...

Page 22: ...16 APPENDIX A...

Page 23: ...00 Hz Note At this frequency the transducers produce equal sound pressure levels TRANSDUCERS Low low mid frequency Two high power 12 cone drivers with neodymium magnets Nominal impedance 2 Voice coil...

Page 24: ...W 1 x 275 W 2550 W peak Note Amplifier wattage rating based on the maximum unclipped burst sine wave rms voltage that the amplifier will produce for at least 0 5 seconds into the nominal load impedan...

Page 25: ...23mm 40 13 70 348mm 23 00 584mm 40 PHYSICAL Enclosure Premium birch plywood Finish Black textured Protective grille Powder coated hex stamped steel black mesh Dimensions 27 07 w x 16 11 h x 23 00 d 68...

Page 26: ...20 APPENDIX B...

Page 27: ......

Page 28: ...2007 Meyer Sound Laboratories Inc 05 157 005 02 A Meyer Sound Laboratories Inc 2832 San Pablo Avenue Berkeley CA 94702 www meyersound com T 1 510 486 1166 F 1 510 486 8356...