background image

6

CHAPTER2

The blue input connector serves as the input for 

all 

the units 

looped in that circuit and is rated at 20 amps maximum. 
Please make sure never to exceed 20 amps on any single 
connector. Refer to Table 2.1.

Table 2.1: Maximum looping capabilities for MJF-212A

Circuit Breaker/
Connector Rating

115 V AC

230 V AC

100 V AC

15 amps

2 Looped-out
(3 total) 

5 Looped-out
(6 total)

1 Looped-out    
(2 total)

20 amps 

3 Looped-out
(4 total)

7 Looped-out
(8 total)

2 Looped-out
(3 total)

 

CAUTION: 

Do not exceed the current 

capability of the 20-amp MJF-212A 

loudspeaker AC connector. When looping always 
take into account the current draw of all the 
speakers in the circuit, 

including

 the first unit.  

         

NOTE:

 For best performance, the AC cable 

voltage drop should not exceed 10 volts, or 

10 percent at 115 volts and 5 percent at 230 volts. 

POwER CONNECTOR wIRING CONVENTIONS

The MJF-212A monitor requires a grounded outlet. Use the 
AC cable wiring diagram below (Figure 2.3) to create power 
connectors.

Figure 2.3. AC cable color code

If the colors referred to in the diagrams don’t correspond to 
the terminals in your plug, use the following guidelines:

 

Connect the blue wire to the terminal marked with an N 
or colored black.

 

Connect the brown wire to the terminal marked with an 
L or colored red.

 

Connect the green and yellow wire to the terminal 
marked with an E or colored green or green and yellow.

         

NOTE:

 For units shipped with the VEAM 

all-in-one multipin connector, please refer to 

Appendix A for AC Power pin-out.

 

CAUTION: 

When creating AC cables 

and distribution systems, it is important 

to preserve AC line polarity and connect earth 
ground on both sides of the cable. MJF-212A 
monitors require a ground connection. Always use 
a grounded outlet and plug. It is very important that 
the system be properly grounded in order to operate 
safely and properly. Do not ground-lift the AC cable.

VOlTAGE REqUIREmENTS

When AC power is applied to the MJF-212A stage monitor, 
the Intelligent AC power supply automatically selects the 
correct operating voltage, allowing the unit to be used 
internationally without manually setting voltage switches 
or jumpers. In addition to selecting the operating voltage, 
the Intelligent AC power supply performs the following 
protective functions to compensate for hostile conditions on 
the AC mains:

 

Suppresses high-voltage transients up to several  
kilovolts

 

Filters common mode and differential mode radio  
frequencies (EMI)

 

Sustains operation temporarily during low-voltage  
periods

 

Provides soft-start power-up, eliminating high inrush 
current

The MJF-212A stage monitor operates safely and without 
audio discontinuity if the AC voltage stays within either of 
two operating windows at 50 or 60 Hz: 

 

85 to 134 volts 

 

165 to 264 volts 

The MJF-212A can withstand continuous voltages up to 
275 volts and allows any combination of voltage to GND 
(that is neutral-line-ground or line-line-ground). 

 

CAUTION: 

Continuous voltages higher than 

275 volts can damage the unit.

Summary of Contents for MJF-212A

Page 1: ...OPERATING INSTRUCTIONS ULTRAseries MJF 212A High Power Stage Monitor Keep these important operating instructions Check www meyersound com for updates...

Page 2: ...to 4600 m 15 000ft Non operating altitude to 6300 m 25 000ft Shock 30 g 11 msec half sine on each of 6 sides Vibration 10 Hz to 55 Hz 0 010 peak to peak excursion 2007 Meyer Sound All rights reserved...

Page 3: ...d by Meyer Sound or sold with the loudspeaker Handles are for carrying only 13 Unplug this loudspeaker during lightning storms or when unused for long periods of time 14 Refer all servicing to qualifi...

Page 4: ...ages auf ein Minimum zu reduzieren den Lautsprecher vom Stromnetz trennen bevor ggf ein Audio Schnittstellensign alkabel angeschlossen wird Das Netzkabel erst nach Herstellung aller Signalverbindungen...

Page 5: ...Electrical Safety Issues 8 CHAPTER 3 Amplification and Audio 9 Audio Input 9 Amplification and Protection Circuitry 9 MJF 212A Interconnections 10 Cabling 10 The Limiting System 10 Low Frequency Limi...

Page 6: ...vi...

Page 7: ...tory installed VEAM Connector Appendix B Specifications and Dimensional Drawings provides detailed acoustic and electrical specifications for the MJF 212A monitor along with detailed dimensional drawi...

Page 8: ...INTRODUCTION...

Page 9: ...m concerts as well as corporate AV applications and clubs The MJF 212A produces a peak output of 139 dB SPL with exceptionally flat phase and frequency response The cabinet is constructed from premium...

Page 10: ...sing package also incorporates Meyer Sound s Intelligent AC power supply which automatically adjusts for common line voltage worldwide and provides both soft turn on and transient protection The MJF 2...

Page 11: ...distribution system with the load between loudspeakers distributed among the three phases and all of the loudspeakers connected to common neutral and earth ground points Figure 2 1 A sample AC power...

Page 12: ...For units shipped with the VEAM all in one multipin connector please refer to Appendix A for AC Power pin out Caution When creating AC cables and distribution systems it is important to preserve AC l...

Page 13: ...o either low or high voltage its power supply automatically turns on again after three seconds if the voltage has returned to either normal operating window If the MJF 212A stage monitor does not turn...

Page 14: ...hat the circuit breakers on the monitor s user panel trip the white center buttons pop out disconnect the AC power cable Do not reset the breakers with the AC connected Contact Meyer Sound for repair...

Page 15: ...loudspeaker If the noise stops most likely the problem is not with the loudspeaker Check the audio cable source and AC power to pinpoint the problem Audio signals can be daisy chained using the Loop o...

Page 16: ...or s left and right 12 inch cone drivers are powered by separate amplifier channels each with a detector but routed to one limiter The lower limit LED on the user panel indicates limiting activity for...

Page 17: ...he temperature of the heatsink reaches 75 C 167 F the On Temp LED on the rear panel turns from green On to red Temp The unit continues to operate normally even if the On Temp LED is red but this is an...

Page 18: ...12 CHAPTER 3...

Page 19: ...his information is permanently retained on each RMS communication board and in the computer RMS database until you modify it Loudspeaker View labels can be modified at any time allowing you to customi...

Page 20: ...e Service Button the card will be decommissioned from the network and the red Service LED will blink Activity LED Green When the loudspeaker has been commissioned the Activity LED will flash continuou...

Page 21: ...neutral blue Figure A 1 VEAM multipin connector power pin out For complete wiring conventions and pin outs for AC audio and RMS connections please refer to the Meyer Sound document VEAM Cable Wiring...

Page 22: ...16 APPENDIX A...

Page 23: ...00 Hz Note At this frequency the transducers produce equal sound pressure levels TRANSDUCERS Low low mid frequency Two high power 12 cone drivers with neodymium magnets Nominal impedance 2 Voice coil...

Page 24: ...W 1 x 275 W 2550 W peak Note Amplifier wattage rating based on the maximum unclipped burst sine wave rms voltage that the amplifier will produce for at least 0 5 seconds into the nominal load impedan...

Page 25: ...23mm 40 13 70 348mm 23 00 584mm 40 PHYSICAL Enclosure Premium birch plywood Finish Black textured Protective grille Powder coated hex stamped steel black mesh Dimensions 27 07 w x 16 11 h x 23 00 d 68...

Page 26: ...20 APPENDIX B...

Page 27: ......

Page 28: ...2007 Meyer Sound Laboratories Inc 05 157 005 02 A Meyer Sound Laboratories Inc 2832 San Pablo Avenue Berkeley CA 94702 www meyersound com T 1 510 486 1166 F 1 510 486 8356...

Reviews: