page 12
LOAD
Channel 1 (switching):
10A of lighting and or ventilation including incandescent, fluorescent, compact fluorescent, low voltage
(switch primary of transformer).
Channel 2 (dimming):
Maximum number of DSI or DALI ballasts is 10 unless the relay is disabled then it is 20.
SUPPLY VOLTAGE
220-240 Volts AC 50 Hz
TIME OUT PERIOD
Adjustable 10 seconds to 99 minutes
LIGHT LEVEL
Light to dark
TERMINAL CAPACITY
2.5mm
2
MATERIAL
Flame retardant ABS
TYPE
Class 2
TEMPERATURE
-10°C to 35°C
SAFETY
The microwave radiation emitted by these units is exteremely low power.
At a distance of > 50mm the power density is <6% of the ANSI IEEE C95.1 –1991
recommended microwave power density.
At a distance of 5mm from the unit it is <84% of recommended power density.
CONFORMITY
EMC-89/336/EEC
LVD-73/23/EEC
13. Specification
Ref #WD417 Issue 1
IMPORTANT NOTICE!
This device should be installed by a qualified electrician in
accordance with the latest edition of the IEE wiring regulations.
Due to our policy of continual product improvement Metway Electrical Industries
reserves the right to alter the specification of this product without prior notice.
Metway Electrical Industries Limited
Barrie House
18 North Street
Portslade
East Sussex
BN41 1DG
Tel:
+ 44 1273 439266
Fax:
+ 44 1273 439288
www.metway.co.uk
[email protected]
page
1. Dimensions
Section
Contents
Page
1
Dimensional information
1
2
Description and operation
2
3
Wiring & Fixing
3
4
Installation
3
5
Fixing - Flush
4
6
Fixing - Surface
4
7
Head locking
5
8
Time, Lux & Sensitivity adjusters
5
9
Programming
6
10
Wiring diagrams
8
11
Detection pattern diagrams
11
12
Fault finding
12
13
Specification
12
14
Part numbers
12
Contents
Direct Dim Microwave Presence/Absence Detector
Product Guide
CRBMWDD3