14
Never use abrasive products or sponges and substances containing acids or chlorine to clean
metal parts, as they can scratch or damage the surface of the parts causing corrosion points. Do not
pour water over the motor and electrical parts for cleaning, otherwise, when turning it on, it may cause
an electric shock or even burn the equipment.
ATTENTION!
It is extremely important that the products used for cleaning ensure maximum hygiene and
that they are non-toxic.
5.2 Breakdown Maintenance and Procedures
The operator must be instructed to carry out routine inspections, making small adjustments,
cleaning and observing signs of breakdowns that may occur. Examples include: checking for strange
noises; equipment power loss; the non-execution by the equipment to the service to which it is
proposed; among others. Actions like these are indispensable to guarantee a longer equipment life.
ATTENTION!
When maintenance is carried out (even if minor adjustments are made), always check that the
equipment is turned off and disconnected from the network.
It is recommended that each 6 months be made preventive maintenance, checking and
adjusting the loose, cleaning the internal parts, and others. Detecting broke parts or without the
correct functionality the worker needs to exchange the parts, always using original parts only.
ATTENTION!
Never let your equipment work without oil in the gearbox, as it will damage your equipment.
Always check the oil level.
It is recommended to change the oil after 6 months of use.
To find out about the quantity and type of oil used in each equipment model, consult the table
in item 2.1 (Technical Data) of this manual.
When changing the oil, use Personal Protective Equipment (PPE) to avoid direct contact with
the oil, such as waterproof PVC gloves.
Follow the instructions below to change the oil in your equipment:
•
Disconnect the equipment from the mains;
•
Remove the funnel and the grinder head (instructions in item 4.3). Remove the case by removing the
fixing screws;
•
Place a container under the gearbox to store the oil to be removed;
•
Remove the screw located under the gearbox. Wait until all the oil comes out of the screw hole.
Summary of Contents for BIMG MCG8110M604
Page 1: ...1 ...
Page 16: ...16 6 ANEXXES Electrical Schematic Single phase Voltage 110 V or 220 V ...
Page 17: ...17 Exploded View Drawing ...
Page 18: ...18 Exploded View Drawing ...