MetroPWR FX1300 User Manual Download Page 1

1

Ver. 1.0.5

Co

www.metropwr.com

Summary of Contents for FX1300

Page 1: ...1 Ver 1 0 5 www metropwr com ...

Page 2: ... malfunction turn it off immediately IMPORTANT INFORMATION Read all the operating instructions safety tips and warnings in the instruction manual Identifying potential hazardous situations and observing the appropriate safety rules will avoid accidents Dangerous situations to avoid in order to prevent all risks that are shown above Never use the FX700 inappropriately but only as described in the u...

Page 3: ...can be used Fast check of all antenna parameters Coaxial cable length measurement Export graphics to your computer Detailed screenshots of the measures Quickly measure resonance of multiband antennas Comparison of many types of antennas Generate RF signals Measurement of the series and parallel parameters of the quartz Complete OSL calibration open load short TDR chart time domain reflectometer It...

Page 4: ...the antenna to the DUT short the antenna connector to ground Up Down change frequency don t remove it Sweep Span Enter manual Frequency OM Band USB PC PORT DUT N type Command POWER ON OFF SD Card USB FOR BATTERY CHARGER Display 4 3 ...

Page 5: ...5 Marker Sweep scan FAST ACCURATE Move marker right FREQ Z SWR MCL Q Zoom SWR Tap here change graph type SAVE Screenshot SWR R X graph Smith chart graph Grap S11 Returnloss Tap here enter frequency ...

Page 6: ...nds This function is very useful for measuring multiband antennas Tap here to enter frequency frequency SWR measure Tone disable Tap here to change the type of series parallel measurement Antenna equivalent circuit Easy Menu enter the antenna frequency and a modulated tone warns when SWR is lower ...

Page 7: ... basic parameters of quartz Fs Fp resonance serial parallel Cs Cp capacity serial parallel Ls inductance Rs resistance Q quality factor Menu Generator possibility to select the frequency and set steps A square wave and all harmonic frequencies will be generated on the DUT connector no filtering expected Equivalent circuit of a quartz KEYB set frequency quartz CAL OPEN disconnect cable on N connect...

Page 8: ... offers two types of calibration 1 Hardware calibration 2 OSL user calibration The HW calibration is made in the factory User can redo it by positioning the rear switch to the right position and proceeding with the calibration This calibration is done only once and it is not necessary to repeat it The switch could be inside the enclosure in this case you need to remove the rear cove After calibrat...

Page 9: ...trace size of graph menu BEEP ON OFF active deactivate beep This is a service menu that displays the spectrum of V I voltage current signals taken from the measurement coupler Through this menu it is possible to select and view the screenshots stored on the sd card In this area it is possible to manage the screenshot files ...

Page 10: ...u 0 hide SCREENSHOT_FOR 0 Screen shot image file format 1 PNG 0 BMP MAT BAND_FMAX 710MHz Maximum operating frequency of the device from 150 to 710MHz SI5351_MAX_FREQ 200MHz Maximum frequency in Hz that Si5351a can reliably output Can be 160MHz or 200 MHz SI5351_CAPS 10pF Si5351 built in quartz capacitors setting 1 for 6pF 2 for 8pF 3 for 10 pF TDR_VF 66 Velocity factor for TDR distance calculation...

Page 11: ...ring OSL calibration MEAS_NSCANS 1 Number of scans to average in measurement window PAN_NSCANS 1 Number of scans to average in panoramic window LIN_ATTENUATION 6 06h Linear audio input attenuation Applied during audio input device initialization after reset Sets the linear audio input volume to 100 ATTENUATION One unit is approximately 1 dB F_LO_DIV_BY_TWO 0 Deprecated references in the code have ...

Page 12: ... can be interfaced with the PC via the left USB port At the moment it is compatible with third party software Through the second right USB port it is possible to download screenshots on the computer in bmp png format ...

Page 13: ...13 USB port Drag drop files in the windows Reboot FX700 FX1300 Connect USB cable ...

Page 14: ...l Smith chart measure antenna multiband TDR time domain reflectometer Cable length measurement Storage of graphics on the sd bmp png card Export images via sd Measure quartz parameters Menu generator Fast accurate scan Battery LI ion included 2600mA USB charging circuit Firmware upgradable via USB 3 7V operating voltage Compact dimensions 135 x 32 x 85 mm Weight 250gr www metropwr com Technical fe...