6.3
BL 4800-M / BL 4800-D: Power supply [X9]
Power data
Characteristic
Value
Supply voltage
24 ... 48 VDC [± 10 %]
Maximum mains current in continuous operation
(S1)
40 A
eff
DC bus voltage
corresponds to the supply voltage
Supplying with power supply unit
The power supply unit used must
l
be able to charge the capacitive load of the DC link capacitors with current
limitation when switched on.
l
be able to tolerate the high voltage at [X9] occurring during braking without raising
an error.
Additional external buffer capacitors can be used to buffer the braking energy.
BL 4800-M / BL 4800-D: Danger of destroying the power supply unit
During braking, a high voltage can be present at [X9], which can destroy the power
supply unit. To prevent this, the switch-off threshold in case of overvoltage must be
suitably parameterised (see section
Power supply via main power unit
in the Product
manual smartServo BL 4000-D / smartServo BL 4000-M).
High charging current when battery is connected
When connecting a battery, a high compensating current (>1000 A) flows until the
internal capacitors of the servocontroller are charged. We therefore recommend initially
connecting the battery via a 1k
Ω
resistor for precharging.
Internal braking resistor
Characteristic
Value
Braking resistor
3.9
Ω
Peak power
1.6 kW
Continuous power
5 W
Mounting Instructions BL 4000-M and BL 4000-D
Page 65 of 95
Summary of Contents for 9200-4104-2000
Page 89: ...9 Appendix BL 4800 M BL 4800 D Mounting Instructions BL 4000 M and BL 4000 D Page 89 of 95 ...
Page 91: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 91 of 95 ...
Page 93: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 93 of 95 ...
Page 94: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 94 of 95 ...
Page 95: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 95 of 95 ...