NSTALLATION
EAS
D
EACTIVATION
SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is a list of
Checkpoint recommended switch bank settings.
Base Model
Checkpoint Recommended Switch Bank Settings
MS2221
SW1 & SW2 switches 1 and 6 set to ON
MS2222
SW1 & SW2 switches 1 and 6 set to ON
All Stratos
S
models have a connector labeled
EAS In
on the bottom of the unit. Metrologic has an optional EAS cable
(
MLPN
52-52511
x
) available for purchase for connection between the Checkpoint device and the Stratos
S
.
Figure 24. EAS Cable Connection (Bottom of StratosS)
The following figure shows the location of the EAS deactivation area for the Stratos
S
. It is important to pass the entire tag
through this area to deactivate the security tag.
Figure 25. EAS Deactivation Area