background image

 

 

65 

S

CANNER 

C

ONFIGURATION 

B

AR 

C

ODES

 

 

EAS Bar Codes 

 

 

EAS Device Types 

 

 

The following codes 

do not

 require that the MS2xx0 to be in scale 

program mode. 

 

EAS Device Type 2 

³

3

3

7

2

2

0

 

 
 
 
 
 
 
 

 

 

EAS Device Type 3 

³

3

3

7

2

3

0

 

 
 
 
 
 

Summary of Contents for Stratos MS2x20 Series

Page 1: ...METROLOGIC INSTRUMENTS INC MS2x20 Stratos Series Configuration Addendum Mettler Toledo Diva Scale ...

Page 2: ...prior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Trademarks Metrologic is a registered trademark of Metrologic Instruments Inc Products identified in this document are hereby acknowledged as trademarks registered or otherwise of Metrologic Instruments Inc or their respective companies ...

Page 3: ... Configuration 5 Scale Settling Filter Configuration 7 Scale Internal Beeper 9 Zero Cursor 10 Quantitative Separator 11 Dual Cable Scale Configuration Bar Codes Scale Protocols 12 Scale COM Port Settings Baud Rate 18 Scale COM Port Settings Data Bits Parity 20 Single Cable Scale Configuration Bar Codes Set Scale for Single Cable Communication 23 SCANNER CONFIGURATION BAR CODES Dual Cable Scanner C...

Page 4: ...tting Full Speed USB Table Top Handheld 37 Special Function ACK 39 Prefix Suffix 40 3x 30 Acknowledge Responses 41 Special Function Command Responses 42 BCC in POS Communications 46 3 Scale Status Bytes 47 Scale Options 48 Remote Display 49 StratosSTATS 50 Additional POS Related Functions Scanner Beep on Weight Sent 53 Restrict In Store Codes 54 Scale Shadow Mode 55 Scanner Razz on Not On File 56 ...

Page 5: ...ndary Metrologic Scanner 62 EAS Bar Codes EAS Device Types 64 EAS Timeout 67 EAS Connection 72 Continuous Mode 75 EAS Deactivation 76 Sensormatic ScanMax Pro 79 SCANNER TEST BAR CODES Supplemental Tests 81 Display Software Numbers 81 CONTACT INFORMATION AND OFFICE LOCATIONS 82 ...

Page 6: ...ken it must be sealed and certified by local Weights and Measures authorities after the scale calibration process has been completed The scanner scale cannot be placed in service until it is sealed and certified by the proper authorities For further details on calibration procedures for Weights and Measures certification refer to the Scale Operation Calibration section of the Stratos Installation ...

Page 7: ... normal operation This is required only for scale configuration items not for calibration Scale Save Data 9 9 6 0 4 5 Scale Type Bar Code The Stratos scanner should have been already programmed to recognize the type K Diva scale If for any reason the scanner s non volatile memory is lost the following bar code must be scanned to reprogram the scanner for the type K Diva scale Type K Diva Scale 4 4...

Page 8: ... following bar codes can be used to configure a Single or Dual Cable MS2xx0 If the MS2xx0 is currently in a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 must be in scale service mode to use these bar codes Pounds Calibration 9 9 6 0 4 2 Set the scale measuring range from 0 00 to 30 00 pounds ...

Page 9: ...lowing bar codes can be used to configure a Single or Dual Cable MS2xx0 If the MS2xx0 is currently in a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 must be in scale service mode to use these bar codes Kilograms Calibration 9 9 6 0 4 4 Set the scale measuring range from 0 000 to 15 000 kilograms ...

Page 10: ...e Data bar code must be scanned last to save the changed configuration see page 2 Scale Display Single Line Weight Only 9 9 6 0 0 3 Set the scale to use a single line weight only display to show all scale activity The single line display must be plugged into the Scale to Display connector on the MS2xx0 see Figure 1 Figure 1 Location of Scale to Display Connector Scale Display 4 line Price Computin...

Page 11: ...porarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale Has No Display 9 9 6 0 0 4 Set the scale to not require a remote display All weights are expected on a POS terminal display A remote display can not be plugged into the Sc...

Page 12: ...scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 The scale s filter setting allows the unit to withstand a certain amount of vibration from the checkout counter A stronger filter allows for more vibration to be absorbed but the weight may take a little longer to settle Scales are normally shipp...

Page 13: ... a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale Medium Filter 9 9 6 0 0 6 Medium filter setting for moderate vibration environments Scale Strong Filter 9 9 6 0 0 7 Strong filter setting fo...

Page 14: ...e to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale Beep On 9 9 6 0 9 0 Enable the internal scale beeper to beep when remote display keys are depressed Scale Beep Off 9 9 6 0 9 1 Turn off the internal beeper inside the scale This is the desired defaul...

Page 15: ...le to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Zero Cursor Off 9 9 6 0 9 2 Turn off the zero cursor that appears on the display when the scale is in the zero weight area Zero Cursor On 9 9 6 0 9 3 Enable the zero cursor to appear on the display when t...

Page 16: ...mporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Decimal Pt Separator 9 9 6 0 9 4 Use a decimal point to separate the units from fraction values on the remote display Comma Separator 9 9 6 0 9 5 Use a comma to separate the un...

Page 17: ...ng the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale EPOS Protocol 9 9 6 0 1 3 Set the scale RS232 protocol to Serial EPOS Communication Port Settings 2400 Baud 7 Data Bits 1 Stop Bit Even Parity Scale EPOS2 Protocol 9 9 6 0 1 4 Set the scale RS232 protocol to Modified Serial EPOS This...

Page 18: ...porarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale 8217 Protocol 9 9 6 0 5 0 Set the scale RS232 protocol to 8217 Communication Port Settings 9600 Baud 7 Data Bits 1 Stop Bit Even Parity Scale 8213 Protocol 9 9 6 0 5 1 Set...

Page 19: ...or to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale ICL Protocol 9 9 6 0 4 9 Set the scale RS232 protocol to Serial ICL Communication Port Settings 2400 Baud 7 Data Bits 1 Stop Bit Even Parity Scale EMEA Special Configuration 9 9 6 0 4 1 Set the scale to EPOS protocol k...

Page 20: ...n a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale NCI Protocol 9 9 6 0 1 6 Reserved for Future NCI Protocol Variation Scale NCI ECR Protocol 9 9 6 0 1 5 Set the scale RS232 protocol to NCI ...

Page 21: ...nfiguration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 NCI 4 Status Bytes 9 9 6 0 5 2 Set the number of status bytes reported by the NCI scale protocol to 4 status bytes Factory Default Setting NCI 2 Status Bytes 9 9 ...

Page 22: ...If the MS2xx0 is currently in a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale Price Compute Setup 9 9 6 0 4 7 Set the scale for price computing setup Price computing display Dialog 06 Proto...

Page 23: ...bar code in order to be effective If the MS2xx0 is currently in a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale 2400 Baud Rate 9 9 6 0 1 7 Set the scale baud rate for dual cable application...

Page 24: ...r code in order to be effective If the MS2xx0 is currently in a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale 19200 Baud Rate 9 9 6 0 1 9 Set the scale baud rate for dual cable applications...

Page 25: ...de in order to be effective If the MS2xx0 is currently in a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale 7 Data Bits Odd Parity 9 9 6 0 2 1 Set the scale communication parameters to 7 data...

Page 26: ...cale Protocol bar code in order to be effective If the MS2xx0 is currently in a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale 8 Data Bits No Parity 9 9 6 0 2 3 Set the scale communication p...

Page 27: ...nned after the Scale Protocol bar code in order to be effective If the MS2xx0 is currently in a Dual Cable configuration temporarily disconnect the Scale to Host cable prior to configuring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 Scale Even Parity 9 9 6 0 2 5 Set the scale communica...

Page 28: ...guring the scale The MS2xx0 does not need to be in scale service mode The Scale Save Data bar code must be scanned last to save the changed configuration see page 2 If your application requires single cable communication scan the following bar code to set the scale configuration to the single cable defaults as required by the scanner Scale Single Cable Interface 9 9 6 0 1 2 Set the scale to commun...

Page 29: ...ceive the scale data and the bar code data is sent via its own cable to a separate communication port Communication Port Settings 9600 Baud 8 Data Bits 1 Stop Bit No Parity There are two methods of configuring the scanner to a stand alone protocol Scan the Dual Cable Mode bar code on this page if a scale is used or If no scale is required scan one of the single cable protocols on pages 27 36 and t...

Page 30: ...d to configure a Dual Cable MS2xx0 The following codes do not require that the MS2xx0 to be in scale program mode REWE 9 9 7 0 1 0 Dual Cable RS232 REWE Communication Port Settings 9600 Baud 7 Data Bits 2 Stop Bit Space Parity TESCO UK 9 9 7 0 1 3 Dual Cable RS232 TESCO UK Communication Port Settings 9600 Baud 8 Data Bits 1 Stop Bit Odd Parity ...

Page 31: ...ng codes do not require that the MS2xx0 to be in scale service mode IBM 3rd Generation Communication 9 9 9 9 5 2 When scanned the Stratos will operate as a table top scanner only Terminal configuration IBM 4690 OS terminal device group configuration screen select 1 scanner or 3 scanner IBM OEM Full Speed USB Communication Defaults 9 9 9 9 7 0 When scanned the Stratos will operate as a table top sc...

Page 32: ...ot require that the MS2xx0 to be in scale service mode MSS Global English 9 9 9 9 5 1 Scanner Scale Single Cable RS232 MSS Global Retail English Units Communication Port Settings 9600 Baud 7 Data Bits 1 Stop Bit Odd Parity MSS Global Metric 9 9 9 9 5 0 Scanner Scale Single Cable RS232 MSS Global Retail Metric Units Communication Port Settings 9600 Baud 7 Data Bits 1 Stop Bit Odd Parity ...

Page 33: ...ng codes do not require that the MS2xx0 to be in scale service mode ISS45 English 9 9 9 9 4 9 Scanner Scale Single Cable RS232 ISS45 English Units Communication Port Settings 9600 Baud 7 Data Bits 1 Stop Bit Even Parity ISS45 Metric 9 9 9 9 4 8 Scanner Scale Single Cable RS232 ISS45 Metric Units Communication Port Settings 9600 Baud 7 Data Bits 1 Stop Bit Even Parity ...

Page 34: ...des do not require that the MS2xx0 to be in scale service mode OPOS English 9 9 9 9 5 8 Scanner Scale Single Cable RS232 OPOS English Scale Defaults Communication Port Settings 9600 Baud 8 Data Bits 1 Stop Bit No Parity OPOS Metric 9 9 9 9 5 7 Scanner Scale Single Cable RS232 OPOS Metric Scale Defaults Communication Port Settings 9600 Baud 8 Data Bits 1 Stop Bit No Parity ...

Page 35: ...not require that the MS2xx0 to be in scale service mode Retailix NCR English 9 9 9 9 5 6 Scanner Scale Single Cable RS232 Retailix NCR Communication English Communication Port Settings 9600 Baud 8 Data Bits 1 Stop Bit No Parity Retailix NCR Metric 9 9 9 9 5 5 Scanner Scale Single Cable RS232 Retailix NCR Comm Metric Communication Port Settings 9600 Baud 8 Data Bits 1 Stop Bit No Parity ...

Page 36: ... bar codes can be used to configure a Single Cable MS2xx0 The following codes do not require that the MS2xx0 to be in scale service mode Retailix OPOS Metric 9 9 7 0 1 9 Scanner Scale Single Cable RS232 Retailix OPOS Communication Metric Communication Port Settings 9600 Baud 8 Data Bits 1 Stop Bit No Parity ...

Page 37: ...ing codes do not require that the MS2xx0 to be in scale service mode IT Retail English 9 9 7 0 0 8 Scanner Scale Single Cable RS232 IT Retail English Communication Port Settings 9600 Baud 7 Data Bits 1 Stop Bit Odd Parity IT Retail Metric 9 9 7 0 0 9 Scanner Scale Single Cable RS232 IT Retail Metric Communication Port Settings 9600 Baud 7 Data Bits 1 Stop Bit Odd Parity ...

Page 38: ...e that the MS2xx0 to be in scale program mode IBM Self Checkout System English 9 9 7 0 2 0 Scanner Scale Single Cable RS232 IBM Self Checkout System English Communication Port Settings 19200 Baud 7 Data Bits 1 Stop Bit Odd Parity IBM Self Checkout System Metric 9 9 7 0 2 1 Scanner Scale Single Cable RS232 IBM Self Checkout System Metric Communication Port Settings 19200 Baud 7 Data Bits 1 Stop Bit...

Page 39: ... codes do not require that the MS2xx0 to be in scale program mode Morrison s Tec Metric 9 9 7 0 2 3 Scanner Scale Single Cable RS232 Morrison s with Tec Display Metric Communication Port Settings 9600 Baud 7 Data Bits 1 Stop Bit Odd Parity Reliance India Metric 9 9 7 0 1 9 Scanner Scale Single Cable RS232 Reliance India Metric Communication Port Settings 9600 Baud 8 Data Bits 1 Stop Bit No Parity ...

Page 40: ...s do not require that the MS2xx0 to be in scale service mode IBM 3rd Generation 46xx English 9 9 9 9 6 0 Scanner Scale Single Cable IBM 46xx RS485 English lbs Terminal Configuration IBM 4690 OS Terminal Device Group Configuration screen select 2 Scanner with integrated scale or 4 4696 scanner scale IBM 3rd Generation 46xx Metric 9 9 9 9 5 9 Scanner Scale Single Cable IBM 46xx RS485 Metric kg ...

Page 41: ...e Cable MS2xx0 The following codes do not require that the MS2xx0 to be in scale service mode IBM OEM Full Speed USB English 9 9 9 9 6 2 Table Top Scanner Scale Single Cable IBM OEM Full Speed USB 4 Digit Weight Mode English lbs IBM OEM Full Speed USB Metric 9 9 9 9 6 1 Table Top Scanner Scale Single Cable IBM OEM Full Speed USB 5 Digit Weight Mode Metric kg ...

Page 42: ...l Speed USB Table Top Handheld The following codes do not require that the MS2xx0 to be in scale service mode Scanner 4B Handheld 3 1 6 4 3 0 Full Speed USB interface to 4B00h handheld usage Scanner 4A Flatbed 3 1 6 4 1 0 Full Speed USB interface to 4A00h table top usage ...

Page 43: ...Table Top Handheld The following codes do not require that the MS2xx0 to be in scale service mode Scanner Scale 4A 6E Table Top 3 1 6 4 4 0 Full Speed USB interface to the 4A00h 6E00h table top scanner scale usage This option is only compatible with Stratos models that have a scale ...

Page 44: ...matting Special Function ACK The following codes do not require that the MS2xx0 to be in scale service mode Enable Special Function ACK Answer 1 4 1 7 1 4 Answer simple special functions with ACK Disable Special Function ACK 1 4 1 7 0 4 Factory Default Setting ...

Page 45: ...atting Prefix Suffix The following codes do not require that the MS2xx0 to be in scale service mode Use Protocol Prefix Suffix 1 4 1 7 1 5 Add protocol prefixes and suffixes to the bar code Program the Prefix Suffix Separate 1 4 1 7 0 5 Factory Default Setting ...

Page 46: ...es do not require that the MS2xx0 to be in scale service mode No 3x 30 Answer 1 4 1 7 1 0 This bar code will inhibit all simple acknowledge 3x 30 answers to POS or OPOS commands 3x 30 Answer 1 4 1 7 0 0 The scanner will answer all NCR and OPOS commands that require a 3x 30 acknowledgement Factory Default Setting ...

Page 47: ...llowing codes do not require that the MS2xx0 to be in scale service mode Spec Func Ans 3x30 1 4 1 9 1 4 Answer Special Function commands in the 3x 30 format as opposed to the Ack Nak which is the norm Spec Func Ans Ack 1 4 1 9 0 4 Answer Special Function commands in the Ack Nak format Factory Default Setting ...

Page 48: ... be in scale program mode Spec Func 30 30 Status 1 4 2 2 1 5 Returns Special Function commands in the 30 30 status as opposed to the 33 30 status Note Requires Spec Func Ans 3x 30 on page Error Bookmark not defined to be set No Spec Func 30 30 Status 1 4 2 2 0 5 Disables redirection of Special Function 3x 30 status to 30 30 status Factory Default Setting ...

Page 49: ...ot require that the MS2xx0 to be in scale program mode No Command Reject Answer 1 4 2 1 1 7 This bar code will ignore sending a command reject answer to the POS mode Send Command Reject Answer 1 4 2 1 0 7 This bar code will send command reject answer to the POS if the command is rejected by the scanner Factory Default Setting ...

Page 50: ...llowing codes do not require that the MS2xx0 to be in scale program mode No Spec Func Answer 1 4 2 1 1 6 This bar code will ignore sending a special function response answer in POS mode Spec Func Answer 1 4 2 1 0 6 This bar code will send a special function response answer to the POS Factory Default Setting ...

Page 51: ... the MS2xx0 to be in scale service mode Skip BCC in messages 1 4 1 4 1 0 This bar code will tell the scanner to NOT expect or transmit the Block Check Character in all message transmissions Add BCC in messages 1 4 1 4 0 0 The scanner will expect and answer all messages with the Block Check Character included Factory Default Setting ...

Page 52: ...s do not require that the MS2xx0 to be in scale service mode Enable 3 Scale Status Bytes 1 2 4 8 1 3 Required for applications where the host system display is the primary scale display and there is no remote pole display connected directly to the scanner scale unit Disable 3 Scale Status Bytes 1 2 4 8 0 3 ...

Page 53: ...nds In order to work properly this bar code must be scanned AFTER scanning one of the English configuration bar codes found on pages 27 36 No Scale 1 4 1 4 0 7 Scan the No Scale bar code 1 If no scale is installed and one of the single cable protocol bar codes found on pages 27 36 has already been scanned 2 If the scale is in a dual cable environment and one of the single cable protocol bar codes ...

Page 54: ...2xx0 to be in scale service mode No Remote Display 1 4 0 9 0 2 When no remote display is installed scan the No Remote Display bar code AFTER scanning one of the configuration bar codes found on pages 27 36 to remove the scale s display from the scanner memory Remote Display 1 4 0 9 1 2 Add remote display to the scanner s memory ...

Page 55: ... a StratosSTATS bar code data formatting active b Bar code Attempt Interval to 0 5 seconds c Time to find supplements code 128 to 0 3 seconds Use StratosSTATS monitor to test this output format When used with a POS it must have the capability to parse and recognize the additional data StratosSTATS Off 9 9 7 0 1 8 Remove StratosSTATS data formatting from the bar code output transmission Factory Def...

Page 56: ...these bar codes unless instructed by a Metrologic Representative Dual Stats Xmit 1 3 8 5 1 1 Allows non RS232 interfaces transmit normally without StratosSTATS and concurrently RS232 interfaces transmit with StratosSTATS Recommended RS232 Settings 38400 Baud 8 Data Bits 1 Stop Bit No Parity No Inter character Delay No Dual Stats Xmit 1 3 8 5 0 1 Factory Default Setting ...

Page 57: ... mode Do not scan these bar codes unless instructed by a Metrologic Representative Dual Xmit Carriage Return 1 3 8 5 1 2 This bar code enables a secondary carriage return suffix to be used only for the dual StratosSTATS RS232 transmission No Dual Xmit Carriage Return 1 3 8 5 0 2 Resets StratsSTATS RS232 dual transmission suffix Factory Default Setting ...

Page 58: ...e in scale service mode Beep on Weight 1 4 1 9 1 7 Request scanner beep when a successful weight is sent This code should only be used for weight on demand applications If used with periodic weight request applications the beeper will be continuously active ON Disable Beep on Weight 1 4 1 9 0 7 When no beep on weight is desired Factory Default Setting ...

Page 59: ...codes do not require that the MS2xx0 to be in scale program mode Restrict In Store Codes 1 2 5 8 1 0 This bar code places tighter restrictions on in store codes These codes are EAN13 Sys2 UPCA Sys2 and Sys4 No Restrict In Store Codes 1 2 5 8 0 0 Disable restrictions on in store codes Factory Default Setting ...

Page 60: ...ire that the MS2xx0 to be in scale program mode Scale Shadow Mode 1 4 2 2 1 7 This bar code sets the scale to the highest priority to allow for frequent scale POS commands This bar code is only to be used in single cable scale mode No Scale Shadow Mode 1 4 2 2 0 7 Disables the Scale Shadow Mode Factory Default Setting ...

Page 61: ...wing codes do not require that the MS2xx0 to be in scale program mode Razz on Not On File 1 4 2 1 1 5 This bar code changes the audible to a razz signal when a Not On File command is received Beep on Not On File 1 4 2 1 0 5 This bar code restores the beep as the Not On File audible Factory Default Setting ...

Page 62: ...cale program mode Do not scan these bar codes unless instructed by a Metrologic Representative Horizontal High DOF 2 1 8 7 0 2 This bar code sets the DOF for all horizontal laser channels to High DOF which allows the farthest scanning Factory Default Setting Horizontal Medium DOF 2 1 8 7 1 2 This bar code sets the DOF for all horizontal laser channels to Medium DOF ...

Page 63: ...t the MS2xx0 to be in scale program mode Do not scan these bar codes unless instructed by a Metrologic Representative Horizontal Close DOF 2 1 8 7 2 2 This bar code sets the DOF for all horizontal laser channels to Close DOF Horizontal Ultra Close DOF 2 1 8 7 3 2 This bar code sets the DOF for all horizontal laser channels to Ultra Close DOF ...

Page 64: ... in scale program mode Do not scan these bar codes unless instructed by a Metrologic Representative Vertical High DOF 2 1 8 7 0 0 This bar code sets the DOF for the vertical laser channels to High DOF which allows the farthest scanning Factory Default Setting Vertical Medium DOF 2 1 8 7 1 0 This bar code sets the DOF for vertical laser channels to Medium DOF ...

Page 65: ...e that the MS2xx0 to be in scale program mode Do not scan these bar codes unless instructed by a Metrologic Representative Vertical Close DOF 2 1 8 7 2 0 This bar code sets the DOF for the vertical laser channels to Close DOF Vertical Ultra Close DOF 2 1 8 7 3 0 This bar code sets the DOF for vertical laser channels to Ultra Close DOF ...

Page 66: ...e mode Auxiliary History Report 9 9 7 0 1 1 The Auxiliary port may be used to download or clear data to StratosSCHOOL The two commands that can be used are Upload Scanner Data and Clear Scanner Data within the Serial Program Interface box on the StratosSCHOOL screen Auxiliary Program Cable MLPN 57 57008x N 3 is required for this feature ...

Page 67: ...ure the Stratos auxiliary port to accept a Metrologic scanner as the secondary scanner Enable Stratos Auxiliary Port 4 3 7 3 2 0 The auxiliary input port s data format must match the main output format of the secondary scanner STEP 2 Configure the secondary scanner to match the auxiliary port s data format Use the Secondary Scanner to scan the following bar codes in the order shown Enter Configura...

Page 68: ...trologic Scanner Configuration sequence continued from previous page Set Stratos Format 4 3 7 5 2 0 Disable Secondary Scanner Beeper 3 1 8 5 0 5 Enable Communication Time Out 1 1 8 4 1 2 Disable CR Suffix 1 1 6 6 0 3 Disable LF Suffix 1 1 6 6 0 2 Exit Configuration Mode 9 9 9 9 9 9 ...

Page 69: ...BAR CODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode No EAS Device 3 3 7 2 0 0 No EAS device is connected Factory Default Setting EAS Device Type 1 3 3 7 2 1 0 ...

Page 70: ...5 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode EAS Device Type 2 3 3 7 2 2 0 EAS Device Type 3 3 3 7 2 3 0 ...

Page 71: ...66 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode EAS Device Type 4 3 3 7 2 4 0 ...

Page 72: ...ER CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 0 seconds 8 4 6 0 0 0 Factory Default Setting EAS 1 second 8 4 6 0 0 1 0 0 ...

Page 73: ...68 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 2 seconds 8 4 6 0 0 2 0 0 EAS 3 seconds 8 4 6 0 0 3 0 0 ...

Page 74: ...69 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 4 seconds 8 4 6 0 0 4 0 0 EAS 5 seconds 8 4 6 0 0 5 0 0 ...

Page 75: ...70 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 7 seconds 8 4 6 0 0 7 0 0 EAS 10 seconds 8 4 6 0 1 0 0 0 ...

Page 76: ...71 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 15 seconds 8 4 6 0 1 5 0 0 EAS 20 seconds 8 4 6 0 2 0 0 0 ...

Page 77: ...ire that the MS2xx0 to be in scale program mode EAS Digital Aux Port 1 4 6 1 0 0 The EAS signals use the RTS and CTS line of the Auxiliary RS232 In connector Factory Default Setting EAS Digital Host Port 1 4 6 1 1 0 The EAS signals use the RTS and CTS lines of the scanner RS232 to Host connector ...

Page 78: ...in scale program mode EAS RS232 on Aux Port 1 4 6 1 1 1 This bar code allows the EAS RS232 signal to use the Tx Out and Rx In lines of the scanner to Aux RS232 In connector No EAS RS232 on Aux Port 1 4 6 1 0 1 There is no EAS RS232 signal Tx Out and Rx In used on the scanner Aux RS232 In connector Factory Default Setting ...

Page 79: ...scale program mode EAS RS232 on Host Port 1 4 6 1 1 2 This bar code allows the EAS RS232 signal to use the Tx Out and Rx In lines of the scanner to Host RS232 In connector No EAS RS232 on Host Port 1 4 6 1 0 2 There is no EAS RS232 signal Tx Out and Rx In used on the scanner to Host RS232 In connector Factory Default Setting ...

Page 80: ...e that the MS2xx0 to be in scale program mode EAS Continuous Mode 1 4 6 1 1 5 When in continuous mode and the scanner is enabled the EAS will always be online to deactivate an EAS tag EAS Interlock Mode 1 4 6 1 0 5 This bar code establishes EAS is used in the Interlocked mode Factory Default Setting ...

Page 81: ... MS2xx0 to be in scale program mode Blink Scan LED on Deactivation 1 4 6 1 1 3 The scanner will blink the scan LED upon receipt of an EAS deactivate acknowledge signal No Blink LED on Deactivation 1 4 6 1 0 3 Do not blink the scan LED upon receipt of an EAS deactivate acknowledge signal Factory Default Setting ...

Page 82: ...at the MS2xx0 to be in scale program mode Fast Beep on Deactivation 1 4 6 1 1 4 Fast beep the scanner s beeper receipt of an EAS deactivate acknowledge signal No Beep on Deactivation 1 4 6 1 0 4 Do not fast beep the scanner s beeper receipt of an EAS deactivate acknowledge signal Factory Default Setting ...

Page 83: ...ollowing codes do not require that the MS2xx0 to be in scale program mode Volume Switch Manual 1 4 6 1 1 6 The volume switch is used for manual EAS deactivation switch Volume Switch Normal 1 4 6 1 0 6 Volume switch is used for normal volume function Factory Default Setting ...

Page 84: ...RS232 EAS cable must be connected to one of the RS232 scanner ports EAS Function 1 9 9 8 0 6 5 For Sensormatic ScanMax Pro get EAS s deactivation count and transmit the information over the current scanner interface EAS Function 2 9 9 8 0 6 6 For Sensormatic ScanMax Pro get EAS s device type and transmits the information over the current scanner interface ...

Page 85: ...must be connected to one of the RS232 scanner ports EAS Function 3 9 9 8 0 6 7 For Sensormatic ScanMax Pro get EAS s hardware version software version and serial number and transmit the information over the current scanner interface ScanMax RS232 Defaults 9 9 9 9 0 9 For Sensormatic ScanMax Pro RS232 default setup AUX port connect 5 second timeout blink LED on deactivate ...

Page 86: ...bserved 2 Digit Display Description of each sequentially displayed sets of digits Example shown will represent 15269 15138 x 1 The first digit of the five main decode processor software number appears right justified 5 2 The second and third digits 6 9 The forth and fifth digits x x Pause before next set of numbers x 1 The first digit of the five digit I O processor software number appears right j...

Page 87: ...82 ...

Page 88: ...NOTES ...

Page 89: ...NOTES ...

Page 90: ......

Page 91: ......

Page 92: ...May 2008 Printed in the USA 0 0 0 2 2 7 2 C ...