Warranty and Disclaimer

Limited Warranty

Products manufactured by Metrologic have a 2-year limited warranty from
date of manufacture.

This warranty is limited to repair, replacement or refund at Metrologic’s
discretion. Faulty equipment must be returned to the Metrologic facility in
Blackwood, New Jersey or Puchheim, Germany. To do this, contact
Metrologic Customer Service/Repair for a Returned Material Authorization
(RMA) number.

In the event that it is determined that the equipment failure is covered under the
warranty, Metrologic shall, as its sole option, repair, replace with a functionally
equivalent unit, or refund an amount equal to the purchase price to the original
purchaser, whether distributor, dealer/reseller, or retail consumer, and return the
equipment to the customer without charge for service or return freight.

This limited warranty does not extend to any Product which, in the sole judge-
ment of Metrologic, has been subjected to misuse, neglect, improper installation
 or accident, nor does it extend to any Product which has been repaired or altered
 by anyone who is not a Metrologic authorized representative. 

THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE, ARISING BY LAW, CUSTOM OR
CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE
AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL
METROLOGIC BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES, INCLUDING, WITHOUT LIMITATION, ANY INJURY TO PROPERTY
OR PERSON OR EFFECT ON BUSINESS OR PROFIT, AND IN NO EVENT SHALL
ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO
METROLOGIC FOR THE PRODUCT.

Metrologic Instruments, Inc.

Customer Service Department 

90 Coles Road

1-800-ID-METRO 

(1-800-436-3876)

Blackwood, NJ 08012

TEL: 609-228-8100
FAX: 609-228-6673

Metrologic Instruments GmbH
Dornierstrasse 2
82178 Puchheim b.
Munich, Germany
TEL: 49-89-89019-0 
FAX: 49-89-89019-200

Summary of Contents for Orbit MS7100

Page 1: ...METROLOGIC INSTRUMENTS INC MS7100 Series Fixed Projection Laser Scanner Installation and User s Guide MLPN 2408 Printed in USA October 1998...

Page 2: ...r Brooklin 05 08 Techlink CEP 04571 090 S o Paulo SP Brasil Singapore 417818 Outside Brazil Tel 65 842 7155 Tel 55 11 5505 6568 Fax 65 842 7166 Fax 55 11 5505 1681 ant888 cyberway com sg info sa metro...

Page 3: ...n PC Keyboard Wedge Interface 7 Scanner Parts 8 Audible Indicators 9 Failure Modes 10 Visual Indicators 11 Labels 12 Depth of Field Specifications 13 Optimal Depth of Field 13 Close Depth of Field 13...

Page 4: ...iv Appendix A Design Specifications 27 28 Appendix B Default Settings 29 32 Appendix C Pin Assignments 33 35 Appendix D Warranty and Disclaimer 36 37 Appendix E Notices 38 39 Index 40 41...

Page 5: ...arge easy to find optimal scan area Orbit increases the first pass read rate for maximum productivity The scanning head can be tilted vertically a full 30 for added flexibility when scanning various s...

Page 6: ...owerLink cable with built in power jack Standard MLPN 54xxx 2 1m 7 straight cord short strain relief or Optional MLPN 53xxx 2 7m 9 coiled cord long strain relief xxx specifies connection to the host K...

Page 7: ...ce the green LED will remain on for the duration of the beep 2 The scanner is shipped from the factory programmed with default settings To configure the MS7100 scanner to meet the host system s specif...

Page 8: ...into the PC 2 Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet Connect AC power to the transformer 3 Listen for a single beep that indicates the scann...

Page 9: ...ck the AC input requirements of the power supply to make sure the voltage matches the AC outlet the socket outlet shall be installed near the equipment and shall be easily accessible Connect AC power...

Page 10: ...n off the host system 2 Make the necessary PowerLink cable connections to the scanner and the host 3 Turn on the host system NOTE a When the scanner first receives power the red LED will turn on Then...

Page 11: ...end of the adapter cable to the PowerLink cable leaving the neces sary termination exposed for connecting to the keyboard and the keyboard port on the PC Refer to Appendix C page 35 for pin assignmen...

Page 12: ...ed as diagnostic indicators and mode indicators Refer to pages 9 11 for details Orbit Face Tilts 30 vertically o for variable position ing of the scan pattern Output Window Laser light emits from this...

Page 13: ...the green light does not flash then the bar code has not been successfully read Razzberry Tone This is a failure indicator Refer to failure modes page 10 Three Beeps during operation During operation...

Page 14: ...failure Return the unit for repair at an authorized service center Continuous Razzberry Tone with both LEDs off If upon power up the scanner emits a continuous razz berry tone then the scanner has an...

Page 15: ...en Flash When the scanner successfully reads a bar code the green LED will flash and the scanner will beep once If the green LED does not flash or the scanner does not beep once then the bar code has...

Page 16: ...unit One label contains information such as the model number date of manufacture serial number and notes that the device is a Class IIa laser product The other label states the device is an LASERKLASS...

Page 17: ...13 Depth of Field Specifications based on 100 UPC bar codes Optimal Depth of Field default Close Depth of Field...

Page 18: ...14 Normal Depth of Field Far Depth of Field...

Page 19: ...15 Depth of Field by Minimum Bar Code Element Width Optimal Depth of Field default...

Page 20: ...16 Close Depth of Field...

Page 21: ...17 Normal Depth of Field...

Page 22: ...18 Far Depth of Field...

Page 23: ...es and dirt can interfere with the proper scanning of a bar code Therefore the output window will need occasional cleaning 1 Spray glass cleaner onto lint free non abrasive cleaning cloth 2 Gently wip...

Page 24: ...being supplied Some host system s cannot supply to the scanner from host enough current to power Orbit Use the power supply included with the scanner 3 beeps on Non volatile RAM failure Contact a Met...

Page 25: ...does not satisfy the programmed criteria UPC EAN codes The scanner defaults to a minimum of 4 character bar code SYMPTOM The scanner scans a bar code but the scanner locks up green LED comes on and st...

Page 26: ...e aspect ratio of the bar code is out of Check print mode The type of printer could tolerance be the problem Change print settings ie change to econo mode or high speed The bar code may have been prin...

Page 27: ...ntercharacter delay SYMPTOM The unit is transmitting each character POSSIBLE CAUSE S SOLUTION Configuration is not correct Increase the interscan code delay setting Adjust whether the F0 break is tran...

Page 28: ...looking for RS 232 data Com port not operating properly Check to make sure that the baud rate and parity of the scanner and the communica tion port match and the program is looking for RS 232 data SYM...

Page 29: ...tware and the scanner configuration match If the applica tion does not support RS 232 scanners a software wedge program that will take RS 232 data and place it into a keyboard buffer may be needed Thi...

Page 30: ...be used for keyboard emulation only However many RS 232 programmable functions that are available in other Metrologic scanners are also available as keyboard wedge functions The most important selecta...

Page 31: ...Keyboard Wedge RS 232 OCIA Light Pen IBM 46xx Stand Alone PC Keyboard Print Contrast 35 minimum reflectance difference No Characters Read up to 80 data characters Maximum number will vary based on sym...

Page 32: ...Temperature 40EC to 60EC 40EF to 140EF Humidity 5 to 95 relative humidity non condensing Light Levels 4840 LUX 450 foot candles Shock Designed to withstand 1 m 3 1 drops Contaminants Sealed to resist...

Page 33: ...232 Pen 46XX UPC EAN T T T T T T T T T T Code 128 T T T T T T T T T T Code 93 T T T T T T T T T T Codabar T T T T T T T T T T Interleaved 2 of 5 ITF T T T T T T T T T T MOD 10 Check on ITF T T T T T...

Page 34: ...T T T Timeout 500 msecs Programmable in 50 msec steps MAX 6 35 seconds Same Symbol Rescan T T T T T T T T T T Timeout 1250 msecs Same Symbol Rescan T T T T T T T T T T Timeout 2000 msecs Intercharacte...

Page 35: ...s Parity Space T T Baud Rate 9600 T T 8 Data Bits T T 7 Data Bits T T Transmit Sanyo ID Characters T T T T Nixdorf ID T T T T LRC Enabled T T T T UPC Prefix T T T T UPC Suffix T T T T Transmit AIM ID...

Page 36: ...100msec steps MAX 800 msec Coupon Code 128 T T T T as code T T T T 39 Programmable Code Lengths 7 aval T T T T T T T T T T Programmable Prefix 10 avail T T Characters Suffix Characters T T Prefixes f...

Page 37: ...mit Output 2 RS 232 Transmit Output 3 RS 232 Receive Input 3 RS 232 Receive Input 4 RDATA 4 RTS Output 5 RDATA Return 5 CTS Input 6 Clock in 6 DTR Input 7 Clock out 7 IBM 46XX Transmit 8 Clock in Retu...

Page 38: ...the other end of the PowerLink Y type cable to the host and keyboard refer to page 7 for details Due to the variations in current supplied by the many available PC s Metrologic suggests the use of an...

Page 39: ...ale connector on one end and a 6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the PowerLink cable leaving the ne...

Page 40: ...ch in the sole judge ment of Metrologic has been subjected to misuse neglect improper installation or accident nor does it extend to any Product which has been repaired or altered by anyone who is not...

Page 41: ...nd haften nicht f r die Richtigkeit im Hinblick auf Inhalt oder Genauigkeit der Angaben dieser Ver ffentlichung oder des hierin beschriebenen Produkts Sie bernehmen ebenso keinerlei Eignungsgarantie o...

Page 42: ...ard Remarque Apr s contr le de cet appareil on a not qu il r pondait aux valeurs limites de la classe A conform ment la partie 15 des directives de l administration f d rale am ricaine pour les t l co...

Page 43: ...en Der Einsatz optischer Ger te mit dieser Laserausr stung erh ht das Risiko einer Sehsch digung N B Dal controllo di questo apparecchio risulta che esso risponde ai valori limite per apparecchi digit...

Page 44: ...7 Configuration procedures 5 7 Connector s 36 Current 4 7 21 29 34 35 Customer service 37 D DC transformer 28 Decode capability 27 Default Settings 29 32 Depth of field 13 18 Design specifications 27...

Page 45: ...1 4 7 23 25 26 27 33 35 Pin assignments 33 35 Port 5 8 21 24 25 35 Powered by 5 6 PowerLink cable 2 4 8 33 35 Power supply 4 5 7 20 33 34 Programming guide 2 3 9 24 26 Protocols 26 Q Quick start 3 R...

Reviews: