8
Operational
Depth of Scan Field
203mm to 457mm (8" to 18")
Scan Speed
Model 870 1250 scan lines per second
Model 875: 450 scan lines per second
Scan Pattern
Model 870: Omnidirectional (20 interlocking lines)
Model 875: 6-line raster
Indicators
LED: green=on ready to scan; red=good read
Beeper Operation
Selection of 3 tones for “Good Read”
Maintenance Required
Clean window periodically
Decode Capability
Autodiscriminates
System Interfaces
RS-232C; Light Pen Emulation; OCIA
Optional Interfaces
Opto coupled 6 amp Us and Canada, 5 amps EEA
countries TRIAC output; object sensor input
Print Contrast
35% minimum reflectance difference
Roll, Pitch, Yaw
360
E
, 60
E
, 60
E
Environmental
Storage Temperature
-40
E
C to 60
E
C (-40
E
F to 140
E
F)
Operating Temperature
0
E
C to 35
E
C (32
E
F to 95
E
F)
Humidity
5% to 95% relative humidity, non-condensing
Light Levels
Up to 3200 foot candles - works in direct sun
Ventilation
None required
Shock
100g for 1ms
ESD
8kV IEC 801-2
Contaminants
Protects against dust, falling dirt, and dripping
non-corrosive liquid
Patents Pending
Specifications subject to change without notice.