background image

METROLOGIC INSTRUMENTS, INC.

MS9535 Voyager 

BT

Wireless Hand-Held Laser Scanner

Installation and User’s Guide

Summary of Contents for MK9535-79A540 - MS9535 VoyagerBT - Wireless Portable Barcode Scanner

Page 1: ...METROLOGIC INSTRUMENTS INC MS9535 VoyagerBT Wireless Hand Held Laser Scanner Installation and User s Guide...

Page 2: ......

Page 3: ...ogic Russia Tel 7 095 50 93 485 Bolshaya Novodmitrovskaya 14 Email info ru metrologic com RU 125015 Moscow Russia ASIA Singapore Metrologic Asia Pte Ltd Tel 65 6842 7155 No 8 Kaki Bukit Place Fax 65 6...

Page 4: ...r Cradle 11 Cradle Parts 12 Scanner Parts 13 Audible Indicators 14 Visual Indicators 15 Failure Modes 17 Programming Modes 18 Upgrading the Flash ROM Firmware 19 Labels 20 Maintenance 20 Depth of Fiel...

Page 5: ...s as a battery charger for the scanner When resting in the cradle the scanner can reach a fully charged state in 2 5 hours When fully charged the scanner can provide up to 12 000 scans For power savin...

Page 6: ...5 547 Receiver Charger Cradle Keyboard Wedge MI9535 537 Receiver Charger Cradle USB AC to DC Power Transformer Regulated 5VDC 2A Output 46 46911 Power Supply China 46 46912 Power Supply United Kingdom...

Page 7: ...anner flashes followed by a 3 combination beeps This means the communication between the cradle and the scanner has been established successfully This is a configuration bar code attached on the cradl...

Page 8: ...the cradle it is in auto trigger mode While in this mode present a bar code in the scanning field and the data is automatically decoded and transmitted 2 CodeGate mode When the scanner is removed from...

Page 9: ...e that the scanned information will be communicated properly to the host system The scanner is shipped from the factory programmed with default settings Please refer to the MetroSelect Programming Gui...

Page 10: ...able with a 5 pin DIN male connector on one end and a 6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the main ca...

Page 11: ...y into an AC outlet 5 Connect the USB cable to the USB port on the host system 6 Turn on the host system Caution To maintain compliance with applicable standards all circuits connected to the scanner...

Page 12: ...ion is broken The connection can be easily broken by placing the unit into sleep mode by holding down the CodeGate button for three 3 seconds For example Scanner 1 has established communication with C...

Page 13: ...harge the scanner place the unit into the cradle The amber LED on the scanner begins to flash indicating the charing process has begun A complete charging process takes about 2 5 hours The amber LED o...

Page 14: ...ct short the positive and negative terminals of the batteries to each other with any metal object Do not pierce strike or step on batteries or subject batteries to strong impacts or shocks Do not disa...

Page 15: ...rations Cradle Version Identifier Communication Protocol s MI9535 5xx 14 Full RS 232 MI9535 5xx 41 RS 232 Light Pen Emulation MI9535 5xx 47 Keyboard Wedge Stand Alone Keyboard Wedge and RS 232 Transmi...

Page 16: ...canner into place c Page Button The page button is located at the rear of the cradle When the scanner associated with the cradle can not be found press the page button the scanner will begin beeping a...

Page 17: ...13 SCANNER PARTS MS9535 Top View MS9535 Side View Amber LED CodeGate Button Output Window Plastic Feet Charge Contacts Blue LED MS9535 Top View White LED...

Page 18: ...upgrade needed the scanner will beep twice followed by alternating flashing of the blue and white LEDs If the scanner gives out two combined high and low tones and flashes blue LED this indicates the...

Page 19: ...munication is not established when the scanner is put into the cradle the amber LED will stay on after a short delay Steady Blue When the laser is active the blue LED is illuminated The blue LED will...

Page 20: ...lash ROM upgrade the alternating flashing of the blue and white LEDs will occur during startup and is accompanied by three beeps Steady White Blue off This indicates the laser is off and the scanner i...

Page 21: ...upon power the scanner emits a continuous razzberry tone the scanner has experienced an electronic failure Return the unit for repair to an authorized service center Three Beeps on power up If the sc...

Page 22: ...A Please refer to these guides for instructions The MetroSelect Single Line Programming Guide can be downloaded for FREE from Metrologic s website www metrologic com MetroSet2 This user friendly Windo...

Page 23: ...rds all RS232 Light Pen 41 keyboard wedge 47 USB 07 and IBM 468X 469X 11 units can be upgraded To upgrade all units an RS 232 cable MLPN 54 54000B N is required Before upgrading the flash ROM within t...

Page 24: ...refore the output window will need occasional cleaning 1 Spray glass cleaner onto lint free non abrasive cleaning cloth 2 Gently wipe the scanner window Patent Information See Manual FCC and ICES 003...

Page 25: ...21 DEPTH OF FIELD Minimum Bar Code Element Width A B C D E F G H J K mm 13 15 19 25 33 53 mils 5 2 5 7 7 5 10 13 21...

Page 26: ...22 IR ACTIVATION...

Page 27: ...Communication is established by scanning the Bluetooth address code of the other device a If the Bluetooth address is headed with FNC3 and consists of a 12 digit hex value e g 3 000CA7FFFF99 scan the...

Page 28: ...d by another Bluetooth device scan the below Provide Service code This will allow other Bluetooth devices to send inquiries to the scanner and attempt communication Use this bar code to establish comm...

Page 29: ...d cradle Establish communication between scanner and cradle before scanning a normal bar code Scanner scans but white LED locks up at one scan and razz twice The distance between scanner and cradle is...

Page 30: ...t is being scanned falls into the criteria Typical of Non UPC EAN codes The scanner defaults to a minimum of 3 character bar code The unit scans a bar code but locks up after the first scan white LED...

Page 31: ...onfigured correctly for this type of bar code Check if check digits are set properly Scanner beeps at some bar codes and NOT for others of the same bar code symbology The minimum symbol length setting...

Page 32: ...RS 232 data Power up OK and scans OK but does not communicate properly to the host Cable not connected to the proper com port Check to make sure that the baud rate and parity of the scanner and the c...

Page 33: ...Blue laser on ready to scan White good read Amber battery full MECHANICAL Length 198 mm 7 8 Width Handle 45 mm 1 8 Head 78 mm 3 1 Depth 40 mm 1 6 Weight Scanner 199 g 7 02 oz Cradle 225g 7 94 oz ELECT...

Page 34: ...a check mark will appear PARAMETER DEFAULT RS 232 LIGHT PEN IBM 46XX KBW USB Normal Scan Mode 9 9 9 9 9 Continuous Scan Mode 9 9 9 9 9 Blinky Scan 9 9 9 9 9 Continuous Blinky Scan 9 9 9 9 9 Custom one...

Page 35: ...s High as Code 39 9 9 Spaces High as Code 39 9 9 Bars High as Scanned 9 9 Spaces High as Scanned 9 9 DTS SIEMENS DTS NIXDORF NCR F NCR S Poll light pen source 9 Beeper tone Normal 9 9 9 9 9 Beep trans...

Page 36: ...scan buffers maximum 4 9 9 9 9 9 Transmit UPC A check digit 9 9 9 9 9 Transmit UPC E check digit 9 9 9 9 9 Expand UPC E 9 9 9 9 9 Convert UPC A to EAN 13 9 9 9 9 9 Transmit lead zero on UPC E 9 9 9 9...

Page 37: ...9 Tab Suffix 9 9 9 DE Disable Command 9 FL Laser 9 Enable Command 9 DTR Handshaking support 9 RTS CTS Handshaking 9 Character 9 Message RTS CTS 9 XON XOFF Handshaking 9 ACK NAK 9 Two Digit Supplements...

Page 38: ...3 avail 9 9 9 9 9 Programmable Prefix characters 10 avail 9 9 9 Suffix characters 10 avail 9 9 9 Prefixes for Individual Code types 9 9 9 Editing 9 9 9 9 9 Inter Scan Code delay programmable 100 sec s...

Page 39: ...232 Transmit Output 3 RS 232 Receive Input 4 PC Data 5 PC Clock 6 KB Clock 7 PC 5V 8 KB Data 9 5VDC 10 Shield Ground MI9535 537 USB Pin Function 1 Ground 2 RS 232 Transmit Output 3 RS 232 Receive Inpu...

Page 40: ...4 54000B N 9 pin D type female connector to the PC Pin Function 1 Shield Ground 2 RS 232 Transmit Output 3 RS 232 Receive Input 4 DTR Input Light Pen Source 5 Power Signal Ground 6 Light Pen Data 7 CT...

Page 41: ...or connecting to the keyboard and the keyboard port on the PC The pin assignments are as follows Main Cable Adapter Cable 5 pin Female DIN 5 pin Male DIN Pin Function Pin Function 1 Keyboard Clock 1 P...

Page 42: ...o abuse misuse neglect improper installation or accident nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or computer system The warranty is...

Page 43: ...e use of wireless radios may be restricted in some situations or environments such as aboard airplanes If you are unsure of restrictions you are encouraged to ask for authorization before turning on t...

Page 44: ...lung aussetzen Der Einsatz optischer Ger te mit dieser Laserausr stung erh ht das Risiko einer Sehsch digung Attenzione L utilizzo di sistemi di controllo di regolazioni o di procedimenti diversi da q...

Page 45: ...sublicense is granted either expressly or by implication estoppel or otherwise under any METROLOGIC or third party intellectual property rights whether or not such third party rights are licensed to M...

Page 46: ...ce 3 5 6 7 37 38 Configuration 13 17 24 35 36 connector 2 Current 28 customer service 2 Customer Service 37 D Decode Capability 28 Default Settings 5 Depth of Field 20 21 Disclaimer 37 F Failure Indic...

Page 47: ...tone 13 30 Razzberry Tone 15 16 Red LED 13 14 25 Repair 16 37 RMA 37 RS 2322 27 29 30 31 32 33 34 35 S SELV 3 5 6 7 Service 37 Specifications 28 stand 2 System Interfaces 28 T Termination 6 Tones 13 1...

Page 48: ......

Page 49: ...September 2003 Printed in China 7 0 7 9 0 0 4 B...

Reviews: