23
U
PGRADING THE
F
IRMWARE
The Voyager series is part of Metrologic's line of scanners with flash upgradeable
firmware. The upgrade process requires a new firmware file supplied to the
customer by a customer service representative and Metrologic's MetroSet
2
software
. A personal computer running Windows 95 or greater with an
available RS232 serial or USB port is required to complete the upgrade.
Do not
use the standard cable supplied with Keyboard Wedge or
RS485
interface kits for firmware upgrades. Use either cable
#54-54014
x
or #53-53014
x.
If using USB or RS232 for the upgrade
process, the standard USB or RS232 cable provided with the scanner
can be used.
To upgrade the firmware in the
MS9520/MS9540:
1. Plug the scanner into a serial communication port on the host system.
2. Start the MetroSet
2
software
.
3. Click on the plus sign (+) next to
POS Scanners
to expand the supported
scanner list.
4. Choose
the
Voyager/9520 N/R
or
Voyager/9540 N/R
from the list.
5. Click on the
Configure Scanner
button.
6. Choose
Flash Utility
from the options list located on the left side of the
screen.
7. Click on the
Open File
button in the Flash Utility window.
8. Locate and open the flash upgrade file supplied by Metrologic.
9. Select the COM port that the scanner is connected to on the host system.
10. Verify the settings listed in the Flash Utility window.
11. Click on the
Flash Scanner
button to begin the flash upgrade.
12. A message will appear on the screen when the upgrade is complete.
Metrologic's customer service department can be reached at
1-800-ID-METRO or 1-800-436-3876.
MetroSet
2
is available for download, at no additional cost, from
http://www.metrologic.com/corporate/download
.
Applicable for IBM
®
host applications