background image

17

IS4215 Pin Assignments

The IS4215 scanner terminates with a 25-pin male D-type connector. The pin
numbers  impress on the connector:

Pin

Signal Name

Function

7

Ground

A power ground that can handle a 500-
milliampere load.

13

Laser/

A +5 VDC input to the head. Its use is to

Motor Control

start the flipper motor and signal processor,
and enable the visible laser diode (VLD). 
This can be a TTL level signal and require
less than 1 milliampere of current.

18

No Connect

19

Power

Primary laser diode/motor power input. +5
VDC should be present at this pin and it can
supply up to 125 mA when enabled by the
signal at pin 6.

20

No Connect

23

Proximity Detect

The proximity detect is a grounding switch that
is active while an object is in the specified
detection field. The controlling computer should
provide a +5 VDC pull up. Ground the +5 VDC
pull up when the proximity detect activates. 

This shows that an object has moved within
scanning range. We recommend that this
signal debounce for approximately 30 milli-
seconds.

Note

:

We did not make the design of this scan 
head to have the continual enabling of the
laser as if the scanner is in a perm-anent
mounting fixture.

Summary of Contents for IS421X ScanGlove

Page 1: ...METROLOGIC INSTRUMENTS INC IS421X ScanGlove Laser Bar Code Scanner Installation and User s Guide MLPN 2187 Printed in USA October 1998...

Page 2: ...Brooklin 05 08 Techlink CEP 04571 090 S o Paulo SP Brasil Singapore 417818 Outside Brazil Tel 65 842 7155 Tel 55 11 5505 6568 Fax 65 842 7166 Fax 55 11 5505 1681 ant888 cyberway com sg info sa metrol...

Page 3: ...canner 4 Audible Indications 5 Visual Indications 6 9 Labels 10 IR Sensor Activation 11 Scan Field 11 Depth of Field and Symbol Specification 12 Maintenance 13 Appendix A Specifications 14 Appendix B...

Page 4: ...er operation is dependent upon your decoder Since there are many decoders available refer to the decoder s documentation concerning scanner requirements and operation Unpacking List With the purchase...

Page 5: ...w out to approximately 4 to 7 Long Range Activation The IR signal initiates the scan process if it senses an object anywhere from the face of the window out to approximately 9 to 13 If the object is r...

Page 6: ...mmunication cable to the decoder controller Connect the other end of the cable to the host device 3 If the decoder controller receives power from an external power supply check the AC input requiremen...

Page 7: ...hows that the scanner has read a bar code successfully When the green light turns off communication to the host is complete Output Window Sends and receives the IR signal and Laser beam Infrared If a...

Page 8: ...eives power the red LED will blink followed by the green LED and then the scanner will beep After the scanner performs this start up sequence the scanner is ready to scan When the scanner successfully...

Page 9: ...red LED Green Flash will flash followed by the green LED and then beep Steady Red once After the scanner performs this startup sequence the red LED will remain on for a specified time show ing that th...

Page 10: ...clignotante diode verte clignotante diode rouge restant allum e Quand le scanner re oit pour la premi re fois de l nergie la diode rouge se met d abord clignoter puis la diode verte Ensuite le scanner...

Page 11: ...Scanner erstmalig Energie zugef hrt wird blinkt zun chst die rote Leuchtdiodenanzeige auf gefolgt von der gr nen Leuchtdiodenanzeige und anschlie end sendet der Scanner ein einmaliges Piep Signal aus...

Page 12: ...diodo l uminoso verde acceso Quando lo scanner viene alimentato per la prima volta lampeggia dapprima il diodo luminoso rosso e quindi quello verde Poi lo scanner emette un unico segnale beep Dopo l...

Page 13: ...ure laser light emitted from this aperture label is located directly over the output window Below are examples of these labels Caution For the scanner to comply with IEC 825 as a Class 1 laser product...

Page 14: ...cts extends approximately 9 13 beyond the output window The IR sensor remains active as long as power is applied to the unit The mode wanted can be manually enabled by repositioning the Short Range Lo...

Page 15: ...80 1 5 5 5 UPC EAN 13 0 100 1 5 6 0 Code 39 7 5 High 1 5 4 0 Code 39 12 0 Medium 2 5 5 5 Code 39 21 0 Low 3 0 6 5 I 2 of 5 7 5 High 1 5 4 0 I 2 of 5 12 0 Medium 3 0 5 5 I 2 of 5 21 0 Low 2 5 6 0 Codab...

Page 16: ...es and dirt can interfere with the proper scanning of a bar code Therefore the output window will need occasional cleaning 1 Spray glass cleaner onto lint free non abrasive cleaning cloth 2 Gently wip...

Page 17: ...ional Depth of Field UPC 100 38 1 mm to 139 7 mm 1 5 to 5 5 Scan Speed 70 scan lines per second Scan Pattern Single scan line Maintenance Clean output window periodically Print Contrast 35 minimum ref...

Page 18: ...polarity does not show scan direction This open collector output can sink 25 mA via an external pull up resistor connected to a voltage not to exceed 20 VDC 2 Data Data is an output digital represent...

Page 19: ...ign of this scan head to have the continual enabling of the laser as if the scanner is in a perm anent mounting fixture 6 Laser A 5 VDC input to the head Its use is to start Motor Control the flipper...

Page 20: ...y laser diode motor power input 5 VDC should be present at this pin and it can supply up to 125 mA when enabled by the signal at pin 6 20 No Connect 23 Proximity Detect The proximity detect is a groun...

Page 21: ...econd which equals 70 scans per second Note The polarity does not show scan direction This is an open collector output that can sink 25 mA via an external pull up resistor connected to a voltage not t...

Page 22: ...ich in the sole judgement of Metrologic has been subjected to misuse neglect improper installation or accident nor does it extend to any Product which has been repaired or altered by anyone who is not...

Page 23: ...nd haften nicht f r die Richtigkeit im Hinblick auf Inhalt oder Genauigkeit der Angaben dieser Ver ffentlichung oder des hierin beschriebenen Produkts Sie bernehmen ebenso keinerlei Eignungsgarantie o...

Page 24: ...ard Remarque Apr s contr le de cet appareil on a not qu il r pondait aux valeurs limites de la classe A c onform ment la partie 15 des directives de l administration f d rale am ricaine pour les t l c...

Page 25: ...en Der Einsatz optischer Ger te mit dieser Laserausr stung erh ht das Risiko einer Sehsch digung N B Dal controllo di questo apparecchio risulta che esso risponde ai valori limite per apparecchi digit...

Page 26: ...053 5 396 055 5 408 081 5 410 139 5 436 440 5 449 891 5 468 949 5 479 000 5 532 469 5 545 889 5 742 043 and 5 756 982 No license right or sublicense is granted either expressly or by implication esto...

Page 27: ...mer Service ii 19 D Depth of Field 11 12 14 Dimensions 14 Disclaimer 20 E Electrical 14 Email ii Environmental 14 ESD 14 Europe ii External Power Supply 3 F Faulty equipment 19 Fax ii G Germany GmbH i...

Page 28: ...14 P Weight 14 Parts 4 Patents 23 Pin assignments 15 18 Power supply 3 Print contrast 14 Programming guide 5 R Red LED 3 6 Repair 19 Rights property 23 warranty 19 RMA 19 Roll pitch yaw 14 S Scan fiel...

Reviews: