background image

 

 

40 

R

EGULATORY 

C

OMPLIANCE  

 

 

Safety 

 

ITE Equipment 

IEC 60950-1, EN 60950-1 

 

LED 

Class 1 LED Product:  IEC 60825-1:1993+A1+A2, 

EN 60825-1:1994+A1+A2

 

 
 
 

Caution 

Use of controls or adjustments or performance of procedures other than those specified herein 
may result in hazardous radiation exposure.  Under no circumstances should the customer 
attempt to service the LED scanner.  Never attempt to look at the LED beam, even if the 
scanner appears to be nonfunctional.  Never open the scanner in an attempt to look into the 
device.  Doing so could result in hazardous radiation exposure.  The use of optical instruments 
with the LED equipment will increase eye hazard. 

 

Atención 

La modificación de los procedimientos, o la utilización de controles o ajustes distintos de los 
especificados aquí, pueden provocar una exposición de luz brillante peligrosa. Bajo ninguna 
circunstancia el usuario deberá realizar el mantenimiento del LED (Diodo Emisor de Luz) del 
lector. Ni intentar mirar al haz del LED incluso cuando este no esté operativo. Tampoco deberá 
abrir el lector para examinar el aparato. El hacerlo puede conllevar una exposición peligrosa a 
la luz del LED. El uso de instrumentos ópticos con el equipo LED puede incrementar el riesgo 
para la vista. 

 

Attention 

L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de 
graves irradiations.  Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou 
la LED.  Ne regardez jamais directement le rayon LED, même si vous croyez que le scanner est 
inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez 
à un risque d’irradiation. L'emploi d'appareils optiques avec cet équipement à LED augmente le 
risque d'endommagement de la vision. 

 

Achtung 

Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder 
Verfahren kann eine gefährliche Licht emittierender Dioden strahlung hervorrufen. Der Kunde 
sollte unter keinen Umständen versuchen, den Licht emittierender Dioden-Scanner selbst zu 
warten. Sehen Sie niemals in den Licht emittierender Diodenstrahl, selbst wenn Sie glauben, 
daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät 
hineinzusehen. Wenn Sie dies tun, können Sie sich einer gefährlichen Licht emittierender 
Diodenstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht 
das Risiko einer Sehschädigung. 

 

Attenzione

 

L'utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel 
presente Manuale può provocare delle rischiose esposizioni radiattive.  Il cliente non deve 
assolutamente tentare di riparare egli stesso lo scanner LED (o diodo emettitore di luce).  Non 
guardate mai il raggio LED (d. emettitore di luce), anche se credete che lo scanner non sia 
attivo.  Non aprite mai lo scanner per guardare dentro l'apparecchio.  Facendolo potete esporVi 
ad una radiazione rischiosa.  L'uso di apparecchi ottici, equipaggiati con raggi LED (d. emettitori 
di luce), aumenta il rischio di danni alla vista. 

 

Summary of Contents for FocusE IS1650

Page 1: ...METROLOGIC INSTRUMENTS INC IS1650 Area Imaging Bar Code Scanner Installation and User s Guide...

Page 2: ...rior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Trademarks Metrologic is a registered trademark of Metrologic Instruments...

Page 3: ...ls 10 INSTALLATION The PowerLink Cable 11 Cable Installation Interface Specific 12 RS232 IS1650 14 12 Keyboard Wedge IS1650 47 13 Stand Alone Keyboard IS1650 47 14 RS485 IS1650 106 15 Low Speed USB IS...

Page 4: ...ement Width 25 IR Activation Range 26 MAINTENANCE Daily Maintenance 27 TROUBLESHOOTING GUIDE Troubleshooting Symptom Solution Chart 28 DEFAULT SETTINGS Communication Parameters 32 SCANNER AND CABLE TE...

Page 5: ...canner s field of view Whether fixed mount or in stand the IS1650 delivers aggressive convenient hands free scanner Firmware updates are easily loaded into Flash memory KEY PRODUCT FEATURES The IS1650...

Page 6: ...Keyboard Wedge Interface is designed for Keyboard emulation use only Many RS232 configurable functions are also available as keyboard wedge functions The following are the most important selectable op...

Page 7: ...download on the Metrologic website www metrologic com OPTIONAL ACCESSORIES Part Description AC to DC Power Transformer Regulated 5 2VDC 1 AMP output 46 00525 120V United States 46 00526 220V 240V Con...

Page 8: ...9213 N 3 USB Full Speed Cable Locking Plus Power Type A straight black 59 59214 N 3 USB Full Speed Cable Locking Plus Power Type A straight black extended length MVC 3M106S IB9 Metrologic Voltage Conv...

Page 9: ...s a Stand Base Qty 1 b Flexible Shaft Qty 1 c Flexible Shaft Cover Qty 1 d Scanner Cradle Qty 1 e 1 4 20 x 1 2 Flat Head Phillips Qty 2 f 8 Round Head Wood Screw Qty 2 Other items may be ordered for t...

Page 10: ...47 cm sec 18 sec 100 UPC in stand Decode Capability Autodiscriminates All Standard 1 D RSS PDF417 microPDF MaxiCode Data Matrix QR Code UCC EAN Composites Postals Aztec OCR A B MICR Optional Decode C...

Page 11: ...tion 330 mA Typical Current Idle Standby 160 mA Typical DC Transformer Class 2 5 2VDC 1 AMP For Regulatory Compliance information see pages 40 42 ENVIRONMENTAL Operating 0 C to 40 32 to 104 F Temperat...

Page 12: ...3 3 White LED See Visual Indicators on page 23 4 Yellow LED See Visual Indicators on page 23 5 Trigger Initiates Bar Code Read 6 Speaker See Audible Indicators on page 22 7 Cable Connection 10 pin RJ4...

Page 13: ...Mounting Hole Dimensions Caution The depth of each mounting hole is 12 mm 0 5 For fixed mount the mounting screws should not be over tightened or go deeper than 10 mm 0 4 passing the bottom surface of...

Page 14: ...re gives an example of the label text and the location Figure 4 Label Samples and Location Caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the...

Page 15: ...the host system is off and the power supply has been disconnected from the PowerLink cable Figure 7 Releasing the PowerLink Cable 1 Locate the small pin hole on the bottom of the unit near the cable 2...

Page 16: ...IS1650 will start to initialize All LEDs yellow white and blue will light for approximately two seconds then start to alternately flash When the scanner has finished initializing the LEDs will stop fl...

Page 17: ...le 6 Connect the power supply transformer to an appropriate AC power outlet 7 The IS1650 will start to initialize All LEDs yellow white and blue will light for approximately two seconds then start to...

Page 18: ...The IS1650 will start to initialize All LEDs yellow white and blue will light for approximately two seconds then start to alternately flash When the scanner has finished initializing the LEDs will sto...

Page 19: ...alizing the LEDs will stop flashing and the unit will beep three times indicating that the scanner is ready for use S Applicable for IBM Host applications Plugging the scanner into a port on the host...

Page 20: ...it will beep three times indicating that the scanner is ready for use As a default the IS1650 38 leaves the factory with USB Keyboard Emulation Mode enabled For information on configuring the IS1650 3...

Page 21: ...LLATION OPTIONAL Metrologic provides two 8 wood screws for securing the stand base to the counter top The following figure provides the pilot hole dimensions for securing the stand base Figure 13 Stan...

Page 22: ...18 INSTALLATION FLEX STAND INSTALLATION OPTIONAL Figure 14 Assembling the Stand...

Page 23: ...is user friendly Windows based configuration program allows you to simply point and click at the desired scanner options This program can be downloaded FREE of charge from Metrologic s website www met...

Page 24: ...e scanner into a serial communication port on the host system 2 Start the MetroSet2 software 3 Click on the plus sign next to Industrial Scanners to expand the supported scanner list 4 Choose the Focu...

Page 25: ...an switch into different modes of operation using the MetroSet2 Software or Area Imaging Supplemental Guide 00 02281 1 The IR detects an object in the IR activation range and automatically turns on li...

Page 26: ...Beeps At Power Up When IS1650 first receives power it will start an initialization sequence All LEDs yellow white and blue will light for approximately two seconds then start to flash alternately Whe...

Page 27: ...ll beep once and the white LED will turn on indicating data is transmitting If the scanner does not beep once and the white light does not turn on then the bar code has not been read successfully Stea...

Page 28: ...ry Tone During Power Up Failed to initialize or configure the scanner If the scanner does not respond after reprogramming return the scanner for repair Short Razzberry Tone During Scanning An invalid...

Page 29: ...rough the use of license numbers provided by Metrologic Units will not support key features such as but not limited to the ability to decode PDF 2D or OCR fonts without the proper licenses Desired lic...

Page 30: ...GE The IS1650 has a built in object detection sensor that instantly turns on the scanner when an object is presented within the scanner s IR activation Area Figure 18 IR Activation Area Specifications...

Page 31: ...only a mild glass cleaner containing no ammonia When cleaning the window spray the cleaner onto a lint free non abrasive cleaning cloth then gently wipe the window clean If the unit s case requires c...

Page 32: ...cable has been used Check that the communication cable matches the unit type and scanner configuration There has been a scanner configuration failure Contact a Metrologic service representative if th...

Page 33: ...that the bar code being scanned falls into the configured criteria i e character length lock or minimum bar code length settings The following item is only relevant for RS232 and serial emulation USB...

Page 34: ...ectly Make sure the scanner is configured for the appropriate mode The next four items are only relevant for a Keyboard Wedge interface The configuration is not set correctly Make sure that the proper...

Page 35: ...interface The com port at the host is not working or not configured properly Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking...

Page 36: ...he interface supports a parameter listed in the charts on the following pages a check mark will appear PARAMETER DEFAULT RS232 RS485S KBW KEYBOARD USB Multi Try Trigger Out of Stand Presentation Mode...

Page 37: ...Communication timeout None Razzberry tone on timeout Three beeps on timeout Same symbol rescan timeout 1000 msecs Same symbol rescan timeout configurable in 50 msec steps maximum of 6 35 sec No Same s...

Page 38: ...ransmit Mod 43 Check digit on Code 39 Transmit Mod 10 ITF Transmit MSI Plessy Parity No Baud Rate 9600 8 Data Bits 7 Data Bits Stop Bits 1 Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefi...

Page 39: ...t Redundancy Coupon Code 128 Configurable Code Lengths 7 avail Code Selects with configurable Code Length Locks 3 avail Configurable Prefix characters 10 avail Suffix characters 10 avail Prefixes for...

Page 40: ...rved 9 5VDC The IS1650 scanner interfaces terminate to a 10 pin RJ45 Female Socket The serial number label indicates the interface enabled when the scanner is shipped from the factory 10 Shield Ground...

Page 41: ...5VDC 10 Shield Ground IS1650 40 Full Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 USB D 7 V USB 8 USB D 9 5VDC 10 Shield Ground S Applicabl...

Page 42: ...ut 8 RTS Output 9 5VDC Stand Alone PowerLink Keyboard Cable 59 59020 3 Straight Pin Function 1 PC Data 2 NC 3 Power Ground 4 5VDC PC Power to KB 5 PC Clock 6 NC USB Power Communication Cable 59 59235...

Page 43: ...6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the PowerLink cable leaving the necessary termination exposed fo...

Page 44: ...ui m me le scanner ou la LED Ne regardez jamais directement le rayon LED m me si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous ex...

Page 45: ...d and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in...

Page 46: ...ference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FC...

Page 47: ...43 PATENTS For patent information please refer to www honeywellaidc com patents...

Page 48: ...of the Product into any mechanical electrical or computer system The warranty is void if i the case of Product is opened by anyone other than Metrologic s repair department or authorized repair cente...

Page 49: ...e 3 4 5 44 D DC 3 7 36 37 38 39 Decode 6 Default Parameters 2 6 32 35 Keyboard Wedge 32 35 RS232 32 35 RS485 32 35 Stand Alone Keyboard 32 35 USB 32 35 Depth of Field 25 Dimensions 9 E EMC 7 41 EMI 41...

Page 50: ...24 28 31 Repair 44 RMA 44 RS232 See Interface S Safety 40 42 SELV 12 16 Service 44 Specifications Electrical 7 Environmental 7 Mechanical 6 Operational 6 Stand 4 5 17 18 21 Stand Alone KB See Interfac...

Page 51: ...47...

Page 52: ...August 2008 0 0 0 2 2 8 7 E...

Reviews: