background image

 

 

7

I

NSTALLING

 

THE 

S

CANNER TO THE 

H

OST 

S

YSTEM

 

 

RS232 MS1690-14 

 

1.  Turn off the host device.  

 

2.  Plug the male 10-pin RJ45 end of 

the PowerLink cable into the 10-pin 
socket on the MS1690.  There will be 
an audible 

click

 when the connector 

lock engages. 

 

3.  Connect the 9-pin D-type connector 

of the communication cable to the 
proper COM port of the host device. 

 

4.  Plug the power supply into the power 

jack on the PowerLink cable.  

 

Check the AC input 
requirements of the power 
supply to verify the voltage 
matches the AC outlet. 
The outlet must be located 
near the equipment and be 
easily accessible. 

 
5.  Connect AC power to the transformer. 

 

6.  The MS1690 will start to initialize.  All LEDs (yellow, white, and blue) will 

light for approximately 2 seconds then start to alternately flash.  When the 
scanner has finished initializing the LEDs will stop flashing and the unit will 
beep 3 times indicating that the scanner is ready for use. 

 

7.  Turn on the host device. 

 

Plugging the scanner into a port on the host system does not guarantee 
that scanned information will be communicated properly to the host 
system.  The scanner is shipped from the factory configured with default 
settings.  Please refer to the MetroSelect Single-Line Configuration 
Guide (

MLPN 

00-02544) or MetroSet

2

’s help files for instructions on 

changing the scanner’s configuration.  In addition, please check that the 
scanner and host system are using the same communication protocol.  

 

See power source caution statement located on page 6 of this manual. 

 

Figure 6. 

Summary of Contents for Focus MS1690-11

Page 1: ...METROLOGIC INSTRUMENTS INC MS1690 Focus Series Area Imaging Bar Code Scanner Installation and User s Guide...

Page 2: ...rior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Trademarks Metrologic is a registered trademark of Metrologic Instruments...

Page 3: ...ull Speed USB MS1690 40 Integrated 11 Low Speed USB MS1690 38 Integrated 11 Stand Kits Stand Components MLPN 46 00147 12 Hard Mounting the Stand 13 Assembling the Stand 14 Scanner Operation Two Defaul...

Page 4: ...ading the Flash ROM Firmware 33 Scanner and Cable Terminations Scanner Pinout Connections 34 Cable Connector Configurations 36 Limited Warranty 38 Regulatory Compliance Safety 39 EMC 40 Patents 42 Ind...

Page 5: ...es aggressive scanning of all standard 1D RSS PDF417 microPDF Composite Matrix and Postal Codes symbology types Firmware updates are easily loaded via Flash ROM The MS1690 series provides an extended...

Page 6: ...da and Japan 46 00526 90VAC 255VAC Continental European 46 00527 90VAC 255VAC United Kingdom 46 00528 90VAC 255VAC Australia 46 00529 90VAC 255VAC China 53 53000 3 RS232 PowerLink Cable with Built in...

Page 7: ...munication Cable Type A 2 7 m 9 ft coiled cord long strain relief black MVC 2MPC IB9 IBM Applications Metrologic Voltage Converter MVC Cable 12VDC to 5 2VDC Contact a Metrologic customer service repre...

Page 8: ...n page 17 2 White LED See Visual Indicators on page 17 3 Blue LED See Visual Indicators on page 17 4 Speaker See Audible Indicators on page 16 5 Trigger 6 Red Window LED Aperture 7 Cable Release See T...

Page 9: ...em is off and the power supply has been disconnected from the PowerLink cable Figure 4 Releasing the PowerLink Cable 1 Locate the small pin hole on the handle of the unit near the cable 2 Bend an ordi...

Page 10: ...h applicable standards all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN IEC 60950 1 To maintain compliance with standard CSA C22 2 No...

Page 11: ...to initialize All LEDs yellow white and blue will light for approximately 2 seconds then start to alternately flash When the scanner has finished initializing the LEDs will stop flashing and the unit...

Page 12: ...easily accessible 6 Connect AC power to the transformer 7 The MS1690 will start to initialize All LEDs yellow white and blue will light for approximately 2 seconds then start to alternately flash When...

Page 13: ...initialize All LEDs yellow white and blue will light for approximately 2 seconds then start to alternately flash When the scanner has finished initializing the LEDs will stop flashing and the unit wi...

Page 14: ...finished initializing the LEDs will stop flashing and the unit will beep 3 times indicating that the scanner is ready for use Plugging the scanner into a port on the host system does not guarantee tha...

Page 15: ...ner is ready for use As a default the MS1690 38 leaves the factory with USB Keyboard Emulation Mode enabled For information on configuring the MS1690 38 for USB Serial Emulation Mode please refer to t...

Page 16: ...N 46 00147 Figure 11 Stand Components Item Description Qty a Stand Base Qty 1 b Flexible Shaft Qty 1 c Flexible Shaft Cover Qty 1 d Scanner Cradle Qty 1 e 20 x 3 8 Flat Head Phillips 100 Undercut Qty...

Page 17: ...Stand Optional Metrologic provides two 8 wood screws for securing the stand base to the counter top The following figure provides the pilot hole dimensions for securing the stand base Figure 12 Stand...

Page 18: ...14 STAND KITS Assembling the Stand Figure 13 Assembling the Stand...

Page 19: ...D will flash and the decoded data will be transmitted to the host Presentation In Stand 1 The IR detects an object in the IR activation range and the scanner s light output automatically starts to fla...

Page 20: ...18 Three Beeps At Power Up When The MS1690 first receives power it will start an initialization sequence All LEDs yellow white and blue will light for approximately 2 seconds then start to alternatel...

Page 21: ...will beep once and the white LED will turn on indicating data is being transmitted If the scanner does not beep once and the white light does not turn on then the bar code has not been successfully r...

Page 22: ...Tone During Power Up Failed to initialize or configure the scanner If the scanner does not respond after reprogramming return the scanner for repair Short Razzberry Tone During Scanning An Invalid bar...

Page 23: ...Bar Code Element Width MINIMUM BAR CODE ELEMENT WIDTH 1D PDF A B C D E F G mm 132 19 254 33 533 254 381 mils 5 2 7 5 10 4 13 21 10 15 9 Figure 16 Depth of Field by Minimum Bar Code Element Width Speci...

Page 24: ...ge The MS1690 has a built in object detection sensor that instantly turns on the scanner when an object is presented within the scanner s IR activation Area Figure 17 IR Activation Area Specifications...

Page 25: ...as been used Check that the communication cable matches the unit type and scanner configuration There has been a scanner configuration failure Contact a Metrologic service representative if the unit w...

Page 26: ...ot match the configured criteria Verify that the bar code being scanned falls into the configured criteria i e character length lock or minimum bar code length settings The unit scans a bar code but l...

Page 27: ...heck digits are set properly The unit beeps at some bar codes and NOT for others of the same bar code symbology The minimum symbol length setting does not work with the bar code Check if the correct m...

Page 28: ...be supported by that country s key look up table Try operating the scanner in Alt mode The com port at the host is not working or not configured properly Check to make sure that the baud rate and par...

Page 29: ...dard 1 D RSS PDF417 microPDF MaxiCode Data Matrix QR Code UCC EAN Composites Postals Aztec Image Transfer BMP TIFF or JPEG output System Interfaces PC Keyboard Wedge RS232 IBM 468X 469X Stand Alone Ke...

Page 30: ...ormer Class 2 5 2VDC 1 A For Regulatory Compliance information see pages 39 41 ENVIRONMENTAL Operating 0 C to 40 32 to 104 F Temperature Storage 40 C to 60 C 40 F to 140 F Humidity 0 to 95 Relative Hu...

Page 31: ...d emulation use only Many RS232 configurable functions available in other Metrologic scanners are also available as keyboard wedge functions The following are the most important selectable options spe...

Page 32: ...sted in the charts on the following pages a check mark 9 will appear PARAMETER DEFAULT RS232 IBM 46XX KBW USB Multi Try Trigger Out of Stand 9 9 9 9 Presentation Mode In Stand 9 9 9 9 Continuous Trigg...

Page 33: ...ore transmit 9 9 9 9 Communication timeout None 9 9 9 9 Razzberry tone on timeout 9 9 9 9 Three beeps on timeout 9 9 9 9 Same symbol rescan timeout 1000 msecs 9 9 9 9 Same symbol rescan timeout config...

Page 34: ...9 9 9 9 Transmit Mod 43 Check digit on Code 39 9 9 9 9 Transmit Mod 10 ITF 9 9 9 9 Transmit MSI Plessy 9 9 9 9 Parity No 9 9 9 Baud Rate 9600 9 8 Data Bits 9 7 Data Bits 9 Stop Bits 1 9 Transmit Sany...

Page 35: ...9 Five digit Redundancy 9 9 9 9 Coupon Code 128 9 9 9 9 Configurable Code Lengths 7 avail 9 9 9 9 Code Selects with configurable Code Length Locks 3 avail 9 9 9 9 Configurable Prefix characters 10 av...

Page 36: ...on program allows you to simply point and click at the desired scanner options This program can be downloaded for FREE from Metrologic website www metrologic com or set up disks can be ordered by call...

Page 37: ...re in the MS1690 1 Plug the scanner into a serial communication port on the host system 2 Start the MetroSet2 software 3 Click on the plus sign next to POS Scanners to expand the supported scanner lis...

Page 38: ...rial label indicates the interface enabled when the scanner is shipped from the factory 10 Shield Ground MS1690 47 Keyboard Wedge Stand Alone Keyboard Pin Function 1 Ground 2 RS232 Transmit Output 3 R...

Page 39: ...round 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 USB D 7 V USB 8 USB D 9 5VDC 10 Shield Ground MS1690 40 Full Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS...

Page 40: ...nal Ground 6 Reserved 7 CTS Input 8 RTS Output 9 5VDC Stand Alone Keyboard PowerLink Cable 53 53020 3 Pin Function 1 PC Data 2 NC 3 Power Ground 4 5VDC PC Power to KB 5 PC Clock 6 NC USB Power Communi...

Page 41: ...nd a 6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the PowerLink cable leaving the necessary termination expose...

Page 42: ...tion or accident nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or computer system The warranty is void if the case of Product is opened by...

Page 43: ...ui m me le scanner ou la LED Ne regardez jamais directement le rayon LED m me si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous ex...

Page 44: ...interference at their own expense Any unauthorized changes or modifications to this equipment could void the user s authority to operate this device This device complies with part 15 of the FCC Rules...

Page 45: ...he FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy...

Page 46: ...hird party intellectual property rights whether or not such third party rights are licensed to METROLOGIC including any third party patent listed above except for an implied license only for the norma...

Page 47: ...2 4 43 D DC 2 29 38 40 41 42 Decode 27 Default Parameters 30 31 34 IBM 31 34 Keyboard Wedge 31 34 RS232 31 34 Stand Alone Keyboard 31 34 USB 31 34 Depth of Field 21 E EMC 29 46 48 EMI 46 48 Emissions...

Page 48: ...fety 44 SELV 8 13 Service 43 Single Trigger 17 Specifications Electrical 29 Environmental 29 Mechanical 27 Operational 27 Stand 4 14 16 17 Stand Alone Keyboard 2 Swiftdecoder 1 T Tone 19 20 Alternate...

Page 49: ...45...

Page 50: ......

Page 51: ......

Page 52: ...January 2008 Printed in USA 0 0 0 2 0 9 8 F...

Reviews: