Metro Fires LTD Euro Ped Installation & Owner'S Operation Manual Download Page 1

• LTD Wee Rad
• LTD Wee Ped

• LTD Xtreme Ped
• LTD Xtreme Rad

• LTD Euro Ped

• LTD Mega Rad
• LTD Mega Ped

LTD Freestanding Models

Wood Fire 

Installation & Owner’s Operation Manual

M1067 01/13

PO Box 11, Inglewood 4347, New Zealand
Ph (06) 756 6520 •  Fax (06) 756 6540
[email protected] • www.metrofires.co.nz

Installation Important information ................... 2
Assembling your Metro ...............................2-3
Floor Protector Installation ............................. 4
Clearances and Specifications ....................... 5
Wetback and flue installation ......................6-7
Operation Important information .................... 8
Where to install a Metro in your home ............ 9
Optional wetbacks ......................................... 9

Getting to know your Metro ......................... 10
Operating your Metro .............................10-11
Cleaning and maintenance  ....................11-12
Troubleshooting ......................................12-13
Metro warranty ............................................ 14
Pioneer wood fire accessories ..................... 15

Summary of Contents for LTD Euro Ped

Page 1: ...etrofires co nz www metrofires co nz Installation Important information 2 Assembling your Metro 2 3 Floor Protector Installation 4 Clearances and Specifications 5 Wetback and flue installation 6 7 Ope...

Page 2: ...been developed to enhance the performance of Metro wood fires Any alternative flue system must have a minimum flue pipe length of 4 2 metres of 150mm diameter flue pipe The 150mm active flue pipe mus...

Page 3: ...lts as shown in Diagram 1 with the open edge facing the front of the Metro up Position the pedestal with its front facing up over the four bolts and fit the nuts and washers supplied Check to ensure t...

Page 4: ...loor protector is established and if the installation is in New Zealand seismic restraint is required Using masonry anchors if the floor protector is on a concrete floor or coach bolts if a wooden flo...

Page 5: ...tional flueshield side extensions When fitted into an alcove situation not projecting forward of the Metro with flueshield side extensions fitted clearances B and G reduce by 80mm for the Wee Ped Clea...

Page 6: ...rough the knockout holes 3 Open the Metro s door and locate two bolts securing the pressed washers which are visible on the left hand side of the firebox for both inlet and outlet connection points 4...

Page 7: ...All Metro s require a 150mm diameter flue Please note All joints in the flue pipe must be sealed with Pioneer fire cement or similar and riveted The base of the flue pipe must be sealed into the outl...

Page 8: ...r to leak into the fire causing the appliance to over fire It is critical that the fire not be operated with over worn faulty or missing bricks baffle plate baffle extension white board on the baffle...

Page 9: ...tems are not suitable for use in locations where the water supply has lime content Lime build up inside the coil will eventually block the coil causing the wetback to fail Cost Savings Wetbacks can en...

Page 10: ...ase of the firebox Add dry kindling and move the air control knob fully to the right being the full open position Light the paper at two or three locations across the front of the door opening and lea...

Page 11: ...of the Metro s firebox and require removal The time this build up takes depends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door an...

Page 12: ...trial and error things to try H Cowl designed purely for downdraft issues but if you have an ECO Cowl fitted as standard you will also need to add another 600mm of flue pipe to compensate as the H Co...

Page 13: ...urn chamber failing Failure of flue pipe or firebox due to creosote build up is not covered under warranty as creosote build up is only possible from either unseasoned fuel or incorrect operation The...

Page 14: ...een neglected by not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden ov...

Page 15: ...od fire keeping it in good order for many years to come Pioneer heating accessories ECO Flue Systems Pioneer Flashrites Pioneer Versatiles Lead Aluminium Silicone Pioneer Fire Cement Pioneer Fireguard...

Page 16: ...page 16...