Metro DataVac CL710K16 User Manual Download Page 1

                                                              

www.metroprepaid.co.za 

 

 

 

 

MET100  

(CL710K16) 

Single Phase  

Prepaid Electronic Meter 

User Manual

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CL710K16

Page 1: ...www metroprepaid co za MET100 CL710K16 Single Phase Prepaid Electronic Meter User Manual ...

Page 2: ......

Page 3: ...arameter Wiring Mode Single Phase Two wire LNNL Basic Current Ib 5A Max Current Imax 80A Starting Curren 0 4 Ib 20mA Rated Voltage Un 230V Voltage Range 70 Un 120 Un Frequency fn 50Hz 5 Accuracy Class Active IEC Class 1 0 Meter Constant Active 1000imp kWh ...

Page 4: ...Name Function Short code Display 3 digit short code Main screen To display electricity quantity demand time voltage current and meter ID number etc Tariff Display the current tariff Unit tag Indicates units of registers 1 Power kW kVA 2 Energy kWh kVAh 3 Current A 4 Voltage V 5 Frequency Hz ...

Page 5: ...he display is as follows 1 Disappears no alert status has been detected 2 Blinks alert event is detected 3 Keep displaying meter failure event has detected Current Reverse tag Indicates reversal current Relay tag Indicates the current relay status The display mode is as follows 1 Keep displaying the relay is in disconnected status 2 Disappears the relay is in connected status 3 Blinks the relay is...

Page 6: ...rved Reserved Reserved Open meter cover tag 1 Disappears meter cover has not been opened 2 Blinks meter cover is opening 3 Keeps displaying meter cover has been turned on and it will disappear after the tampering is reset Open terminal cover tag 1 Disappears terminal cover has not been opened 2 Blinks terminal cover is opening 3 Keep displaying terminal cover has been turned on and it will disappe...

Page 7: ... LED is red and will blink when alert events occurred and keeps displaying when the relay is tripping Credit LED When the credit is normal the credit LED will keep displaying Green Low credit threshold the credit LED will blink in green The emergency mode is not activated and relay open when arrears the credit LED will blink in red Power Consumption in emergency mode or power consumption during fr...

Page 8: ...ain 20 digit TOKEN 5 3 Recharge Meter Input the 20 digits of purchasing TOKEN via keypad Confirm the entered TOKEN code on the display If TOKEN input is incorrect please delete it with on the keypad After the input TOKEN is correct press to confirm If TOKEN is correct accept will be displayed on the screen and meter recharge is successful If TOKEN is incorrect reject will be displayed on the scree...

Page 9: ...correct and the breaker on the main board is ON 2 Check whether voltage is within operating range LCD displays normal but the energy pulse LED doesn t flash during power consumption 1 Check whether the wiring is connected properly 2 Power usage amount is less than 0 4 Ib 8 Cleaning the Meter Use a soft cloth to clean meter until it is clean The meters must be cleaned regularly Don t use sharp obje...