Metrix 6850-001 Installation Manual Download Page 1

6850-001 Impact Meter

Installation Manual

DOC# 100850 • REV B (April 2018)

6850 connected 

to an IT6810

The 6850 Impact Meter is designed for quick 

check out or adjustment of Metrix Impact 

transmitters, either on an operating ma

-

chine, or with the transmitter removed.

Simply connect the Meter to an Impact 

transmitter, toggle the Power switch, and 

select Pulse-Time, 4-20mA, or Peak Detect 

mode. In Pulse-Time mode, the transmit

-

ter’s Threshold level (milli-volts), and Sam

-

ple Time (seconds) are displayed, and may 

be adjusted while observing the changes. 

Switching to 4-20mA mode displays the 

current output directly, while Peak Detect 

mode displays the peak vibration level, in 

milli-volts, detected by the transmitter.

The Peak Detect mode is provided for 

measuring and displaying the amplitude of 

Impact peaks present at the measurement 

location. Peak Detect mode is most useful 

when “fine tuning” a transmitter for a par

-

ticular machine. An Impact Threshold Level 

2X to 3X the base line PD level has proven to 

provide good machinery protection moni

-

toring. While the Pulse Time is a function 

of machine operating speed, calculated as 

follows: 960 divided by machine RPM = the 

Pulse Time (in seconds).

OVERVIEW

Summary of Contents for 6850-001

Page 1: ...nd may be adjusted while observing the changes Switching to 4 20mA mode displays the current output directly while Peak Detect mode displays the peak vibration level in milli volts detected by the tra...

Page 2: ...itter removed Simply connect the Meter to an Impact transmitter toggle the Power switch and select Pulse Time 4 20mA or Peak Detect mode In Pulse Time mode the transmitter s Threshold level millivolts...

Page 3: ...put switch 3 to T PT as shown in Figure 2 NOTE During initial power on of the Impact Meter it may be necessary to wait up to 10 seconds for the Threshold and Pulse Time measurements to stabilize Figur...

Page 4: ...e pulse time period setting of the Impact Transmitter and uses this to determine the internal timing of the measurement The Peak Detect mode enables the Impact Meter to measure the Peak impact voltage...

Page 5: ...of thumb it is rec ommended that the threshold level be set 2 to 3 times the peak level during normal operation 4 20mA Measurement To initialize the 4 20mA measurement mode set input switch 2 to 4 20...

Page 6: ...receiving this message the batteries should be replaced to avoid any potential measurement errors To replace the batteries on the Impact Meter remove the 6 screws on the back of the case as shown in...

Page 7: ...Doc 100850 REV B April 2018 Page 7 of 8...

Page 8: ...reason Waste Electrical and Electronic Equipment commonly known as WEEE should never be disposed of in the public waste stream The Crossed Out Waste Bin label affixed to this product is a reminder to...

Reviews: