MI 3242 MicroOhm 2A
Data handling
32
7.4 Recalling test results
Press the
MEM
key in a main function menu when there is no result available for storing
or select
MEMORY
in the
SETTINGS
menu.
Figure 7.3: Recall menu - structure field
selected
Figure 7.4: Recall menu - measurements
field selected
Keys in recall memory menu (structure field selected):
TAB
Selects the location element (Object / Loc1 / Loc2).
UP / DOWN
Selects number of selected location element (1 to 199).
MEM
Enters measurements field.
TEST /
FUNCTION
SELECTOR
Exits back to
Main menu
.
Keys in recall memory menu (measurements field selected):
UP / DOWN
Selects the stored measurement.
TAB
Returns to structure field.
MEM
View selected measurement results.
TEST /
FUNCTION
SELECTOR
Exits back to
Main menu
.
Figure 7.5: Example of recalled measurement result
Keys in recall memory menu (measurement results are displayed):
UP / DOWN
Displays measurement results stored in selected location.
MEM
Returns to measurements field.
TEST /
FUNCTION
SELECTOR
Exits back to
Main menu
.