10.15
General data
Power supply voltage 9 V
DC
(6
1.5 V battery or accu, size AA)
Operation ............................................... typical 20 h
Charger socket input voltage ................. 12 V
10 %
Charger socket input current .................. 400 mA max.
Battery charging current ........................ 250 mA (internally regulated)
Measuring category ............................... 600 V CAT III
300 V CAT IV
Protection classification ......................... double insulation
Pollution degree ..................................... 2
Protection degree .................................. IP 40
Display .................................................. 128x64 dots matrix display with backlight
Dimensions (w
h
d) .......................... 23 cm
10.3 cm
11.5 cm
Weight .................................................. 1.3 kg, without battery cells
Reference conditions
Reference temperature range ................ 10
C
30
C
Reference humidity range ...................... 40 %RH
70 %RH
Operation conditions
Working temperature range ................... 0
C
40
C
Maximum relative humidity .................... 95 %RH (0
C
40
C), non-condensing
Storage conditions
Temperature range ................................ -10
C
+70
C
Maximum relative humidity .................... 90 %RH (-10
C
+40
C)
80 %RH (40
C
60
C)
Communication transfer speed
RS 232 .................................................. 57600 baud
USB ....................................................... 256000 baud
Size of memory ...................................... up to 1800 measurements
The error in operating conditions could be at most the error for reference conditions (specified in
the manual for each function) +1 % of measured value + 1 digit, unless otherwise specified in