Page 2: ...r equipment certifies that it meets requirements of all subjected EU European Union regulations 2019 METREL The trade names Metrel Smartec Eurotest Auto Sequence are trademarks registered in Europe and other countries No part of this publication may be reproduced or utilized in any form or by any means without permission in writing from METREL ...

Page 3: ...e 4 2 Safety and operational considerations 5 2 1 Warnings and notes 5 2 2 Markings on the adapter 5 2 3 Standards applied 6 3 Adapter description 7 4 A 1532 operation 8 5 Maintenance 10 5 1 Cleaning 10 5 2 Service 10 6 Technical specifications 11 6 1 General data 11 ...

Page 4: ...ments The A 1532 is an extender for interfacing Electric Vehicle Supply Equipment EVSE to test socket of installation tester for verification of electrical safety and functional testing It is intended for testing Mode 3 EV supply equipment with type 2 connector A 1532 ESVE adapter is a special accessory intended to be used with METREL installation testers ...

Page 5: ...efully otherwise use of the A 1532 may be dangerous for the operator for test equipment or for the tested object Do not use the A 1532 if any damage is noticed Mains test sockets and banana sockets are intended for test purposes only Do not connect any other devices except METREL installation test equipment Service intervention is allowed to be carried out only by a competent authorized person All...

Page 6: ...rement control and laboratory use Part 2 030 Particular requirements for testing and measuring circuits EN 61010 031 Safety requirements for hand held probe assemblies for electrical measurement and test Functional EN 61851 1 Electric vehicle conductive charging system Part 1 General requirements Note about EN and IEC standards Text of this manual contains references to European standards All stan...

Page 7: ...d current rating detection 4 Control Pilot CP STATE resistance selector for simulation of electric vehicle status 5 Socket output for connection to single phase installation tester Socket output is intended for test purposes only Do not use it as power supply extender 6 Type 2 Male Plug connector for connection to EVSE 7 BNC output connector for checking Control Pilot CP signal BNC output connecto...

Page 8: ...f the EVSE In PP STATE 3 position different to N C and CP STATE 4 position in C or D the EVSE output is energized indicated by one or more 2 Voltage on EVSE indicators Run installation tests for energized installation circuits Set CP STATE 4 to position A to de energize EVSE before disconnecting A 1532 plug 6 from EVSE Note Only phase L1 of 3 phase EVSE is accessible through test socket 5 Figure 4...

Page 9: ... pilot and control pilot functions of EVSE can be checked Checking CP signal Connect Oscilloscope to BNC connector 7 using 10 1 probe with 10 MΩ input resistance Set PP STATE 3 position to proper EVSE current output selection Set CP STATE 4 to position A Set tested EVSE to operate Set CP STATE 4 to position B and or C and modify PP STATE 3 position to all applicable currents Check waveforms and am...

Page 10: ...special maintenance is required for the housing To clean the surface of the adapter use a soft cloth slightly moistened with soapy water or alcohol Then leave the A 1532 to dry totally before use Warnings Do not use liquids based on petrol or hydrocarbons Do not spill cleaning liquid over the adapter 5 2 Service For repairs under warranty or at any other time please contact your distributor ...

Page 11: ...ce BNC case to PE 100 kΩ Resistance BNC contact to CP 100 kΩ Amplitude error 10 MΩ probe 2 Protection classification double insulation Pollution degree 2 Protection degree IP 40 Measuring category 300 V CAT II Altitude up to 3000 meters above sea level Dimensions w h l 10 cm 7 cm 25 cm Test lead s length 0 5 m Weight 0 90 kg Operation conditions Working temperature range 0 C 40 C Maximum relative ...