background image

 

 

 

 
 

METREL test and measurement accessories: 

 
 

 

 
 
 
 

3-Phase Active Switch 

A 1507 

Instruction manual 

Version 1.1.1, Code no. 20 752 862 

 

Summary of Contents for A 1507

Page 1: ...METREL test and measurement accessories 3 Phase Active Switch A 1507 Instruction manual Version 1 1 1 Code no 20 752 862...

Page 2: ...b site http www metrel si e mail metrel metrel si Mark on your equipment certifies that it meets requirements of all subjected EU regulations 2018 METREL No part of this publication may be reproduced...

Page 3: ...tery cells or cells unused for a longer period 7 4 A 1507 Description 9 4 1 Connection panel 9 4 2 Bottom side 10 4 3 A 1507 set and accessories 12 4 3 1 Standard set 12 4 3 2 Optional accessories 12...

Page 4: ...g and using METREL A 1507 3 Phase Active Switch accessory with METREL test and measuring instruments The A 1507 simplifies testing of 3 phase installations with single phase installation testers It is...

Page 5: ...507 is used in a manner not specified in this Instruction manual or the manual of target test equipment the protection provided by the A 1507 and equipment may be impaired Read this Instruction manual...

Page 6: ...ing testing or measuring circuits EN 61010 031 Safety requirements for electrical equipment for measurement control and laboratory use Part 031 Safety requirements for hand held probe assemblies for e...

Page 7: ...ot used for longer period Do not charge alkaline battery cells Take into account handling maintenance and recycling requirements that are defined by related regulative and manufacturer of alkaline or...

Page 8: ...ficantly decreased operation time reversed polarity of defective cell If no improvement is achieved after several charge discharge cycles then each battery cell should be checked by comparing battery...

Page 9: ...r socket 3 Banana safety sockets for connection to tested 3 phase electrical installation 4 Supply and operational state indicator LED status Charging Blue blinking Battery in good condition Green Bat...

Page 10: ...ase Active Switch A 1507 Description 10 4 2 Bottom side Figure 4 2 Back panel Legend 1 Serial number label 2 Battery compartment cover 3 Back panel information label 4 Fixing screws for battery compar...

Page 11: ...Phase Active Switch A 1507 Description 11 Figure 4 3 Battery compartment Legend 5 Battery cells Size AA alkaline rechargeable NiMH 6 Battery holder 7 RS 232 communication port For A 1507 service purp...

Page 12: ...1 5 mm2 1 pc blue Test lead 1 5 m 1 5 mm2 1 pc green Alligator clips 3 pcs black Alligator clip 1 pc blue Alligator clip 1 pc green Set of Ni MH battery cells Power supply adapter Soft carrying bag Wa...

Page 13: ...luetooth communication active sign on master instrument Set test parameters limits A 1507 will automatically set to position according to set parameters Active communication and correctly set position...

Page 14: ...rotestXC MI 3152H EurotestXC 2 5 kV and MI 3155 EurotestXD 5 3 Supported measurements In general A 1507 allows to carry out following measurements in 3 phase systems Continuity of protective conductor...

Page 15: ...cial maintenance is required for the housing To clean the surface of the adapter use a soft cloth slightly moistened with soapy water or alcohol Then leave the A 1507 to dry totally before use Warning...

Page 16: ...ation double insulation Pollution degree 2 Protection degree IP 54 Measurement category 600 V CAT III 300 V CAT IV Dimensions w h l 13 cm 7 cm 20 cm Instrument cable length 0 5 m Weight 0 6 kg without...

Reviews: