Page 18
Locker Controller ELS ASSIGN Touch Technical Manual
STEP 8:
Close the Locker Controller Box/Locker (see Locker manufacturer's documentation).
Maintenance
No special maintenance is needed.
The maintenance people should check the device operation at least once a year.
NOTE
Direct spraying or splashing water can cause damage to Locker Controller or Electric Locks!
Troubleshooting Guide
trouble
explanation / solution
Locker door closed while locking and nothing happens. Adjust the door strike. Check the Electric Lock. Replace
the Electric Lock if necessary.
The Locker door not ejected when unlocked.
Adjust the door strike.
Technical data
Operating voltage
12V DC regulated (11.5 – 15V DC tolerated)
Current consumption
PCB: 0.65 A peak, 0.45 A average
PCB with two extension modules: 2 A peak, 1 A average
Operating temperature range
0 to +50 °C
Audio signal
integrated piezoelectric beeper
Buffer capacity
40 records
Electronic Lock Interface
Up to 16/24/32 El. Locks, 6 wire flat cable, max. length 20m
Dimensions in mm (w/h/l)
100/20/179 main electronics
100/20/89 extension board
171/5/380 mounting plate
Connections
Power, Metra NET Network, Display, Coin acceptor, external
Emergency open push-button,
Appendix
1
Physical dimensions
Locker Controller
Locker Controller Extension Module