Methven Australia Pty Ltd
ABN 15 104 813 390
Melbourne, Australia
www.methven.com
WMKA21005
IMPORTANT
Please read all of the instructions before installation
MA018185
Waipori Shower Mixer
with Diverter
01-8185
Use of this product is recommended for domestic and commercial applications.
Domestic and commercial warranty terms and conditions vary. Please refer to the Methven website
for full warranty terms and conditions - www.methven.com
All pipework must be thoroughly flushed prior to the installation of the mixer.
Inline filter washers must be installed on both hot and cold supplies to prevent foreign particles
damaging the ceramic cartridge.
Do not remove the ceramic cartridge from the mixer when installing.
Damage caused by hydrostatic testing is not covered by Methven’s warranty.
Methven recommends a licensed plumber carry out all installations in compliance with
the requirements of AS/NZS 3500. This product complies with AS/NZS 3718 regulations.
April 2012
Installation Guide
Ceramic Cartridge
Adjustment
Do not remove the ceramic cartridge
from the body while carrying out the
following adjustments.
Note: the cartridge is factory
set for maximum temperature.
www.methven.com
Customer Care Hotline: 1300 METHVEN (638 483)
Email: [email protected]
Remove half-dome (if attached)
Flow limiting
adjustment
Mix
temperature
limiting
adjustment
+
+
-
Installation
1. Remove the body assembly cover. Do not
discard cover or screws (3).
2. Screw the body assembly (1) on to the
mounting stud positioned to observe the
installation depth range as follows:
Range of Install Depth, ID = 67 to 89 mm
Note: Two sizes of half dome (5 & 6) are
supplied.
Long dome (6) for 67-77 mm
Short dome for (5) for 77-89 mm
3. Connect body assembly (1) into system and
replace body assembly cover.
4. Cut holes in lining as pictured.
5. Remove body assembly cover prior to
application of the wall surface finish e.g.
tiles.
6. Lubricate the o-ring in the faceplate (2).
Place faceplate (2) over mixer body and
slide firmly over the mixer body until flat on
the wall surface. It is recommended that
a bead of silicone sealant is applied to the
back of the faceplate before fixing to the
finished wall surface. Screw the faceplate
(2) into the fixing ring using the screws
provided.
7. Place o-ring and appropriate half dome (5
or 6) over the body assembly (1). Fit diverter
knob (7) by screwing it onto the diverter
plunger. Fit handle (8) and fasten grub
screw with 2.5mm hex key (9) supplied.
Hole cut out
100mm
1
5
Do not discard screws
ID
Hot
Cold
2
3
6
7
4
100mm
25mm
50mm
Use appropriate Half Dome
for installation depth.