Hot
Distance from
mounting stud to
front of lining:
Max 67 mm
(optimum) Min 56mm
Note: It is the responsibility of the installer to ensure a water proof seal
is achieved between the faceplate and the finished surface of the wall.
If in any doubt about the quality of the seal, the faceplate should be
removed and then reinstalled using silicone to ensure a seal is achieved.
MA016150
Tahi Shower Mixer
01-6150
JULY 2011
WMKA00076
Remove half-dome
(if attached)
Flow limiting adjustment
Mix temperature limiting
adjustment
1.5mm Allen Key
IMPORTANT
Please read all of the instructions before installation
Use of this product is recommended for domestic and commercial applications.
Domestic and commercial warranty terms and conditions vary. Please refer to the Methven website
for full warranty terms and conditions - www.methven.com
All pipework must be thoroughly flushed prior to the installation of the mixer.
Inline filter washers must be installed on both hot and cold supplies to prevent foreign particles
damaging the ceramic cartridge.
Do not remove the ceramic cartridge from the mixer when installing.
Damage caused by hydrostatic testing is not covered by Methven’s warranty.
Methven recommends a licensed plumber carry out all installations in compliance with
the requirements of AS/NZS 3500. This product complies with AS/NZS 3718 regulations.
Installation Guide
Illustration may not reflect actual product shape
Do not discard screws
Refer to back page
for correct nozzle selection
Hole cutout
102mm
Apply silicone
sealant
Cold
2.5mm Hex key
1
2
3a
3b
4
5-7
Ceramic Cartridge
Adjustment
Do not remove the ceramic cartridge from the body while
carrying out the following adjustments.
Note: the cartridge is factory set for maximum
temperature.
Installation
1
. Remove body assembly cover. Do not discard cover or
screws (3).
2. Screw the body assembly (1) into the mounting stud.
3. Plumb body assembly (1) into system and replace body
assembly cover. The minimum distance from mounting stud
to front wall lining is 56mm with a maximum distance of
67mm (optimum).
Note: Body assembly cover will need to be removed
before wall surface finish (tiling) is applied. A hole
diameter of 102mm will be required for correct mixer
installation.
4. Place faceplate (2) over mixer body and fit flush with wall
surface. It is recommended that a bead of clear silicone
sealant is applied on the back of the faceplate before fixing
to finished wall surface.
5. Screw the faceplate (2) into the fixing ring using the screws
(3) taken from the body assembly cover.
6. Place the O-ring (4) and half dome (5) over the body
assembly.
7. Fit handle (6) and fasten grub screw with 2.5mm hex key (8)