Metel M-MDR-100-48 Installation Manual Download Page 1

www.metel.eu

 

1

/

12

 

Installation Manual

 

rev. 201606

 

This document contains installation instructions for the switches of the following versions:

 

 
2G-2S.0.2.F-BOX-PoE 
2G-2S.0.2.F-BOX-PoE-PP 
2G-2S.0.3.F-BOX-PoE 
2G-2S.0.3.FC-BOX 
2G-2S.3.0.F-BOX 
2G-2S.1.4.F-BOX-PoE-PP

 

 

 1 

 

The package contains

 

 1.1 

 

Switch 

 1.2 

 

Power Supply Connector 

 1.3 

 

DIN Rail mounting kit  

 1.4 

 

Mounting kit for  wall placement 

 1.5 

 

Product Datasheet which includes the Installation Manual 

 

 2 

 

Software

 

The following freeware applications are available for download from 

www.metel.eu

 

Freeware configuration software 

SIMULand.v4

 

 

Freeware software 

VcomNet

  for RS485 communication over virtual COM ports 

 

USB drivers 

Software is compatible with OS Windows 7, Windows 8.1 and Windows 10 (32 and 64b).

 

 

 

Summary of Contents for M-MDR-100-48

Page 1: ...e contains 1 1 Switch 1 2 Power Supply Connector 1 3 DIN Rail mounting kit 1 4 Mounting kit for wall placement 1 5 Product Datasheet which includes the Installation Manual 2 Software The following fre...

Page 2: ...is recommended to use one of the following power supplies Input voltage for the supplies is 230VAC 5 Type Maximal power Operational temperature Output voltage M MDR 40 48 40W 20 C 70 C 48 55VDC M MDR...

Page 3: ...he main and redundant power supply The switch always takes current from a higher voltage and when it is disconnected the switch without interruption automatically switches to a lower redundant power s...

Page 4: ...ules Connection 8 1 Insert the SFP module into the free SFP slot in the switch 8 2 For correct functioning of the LAN RING v1 and v2 systems it is essential to maintain proper connection of the GBIC m...

Page 5: ...d in priority SLAVE 9 2 Topology Optical Ring Switches support topology optical ring Before the ring is closed it is necessary to set a Ring ID for all switches and one switch must be in MASTER mode I...

Page 6: ...ter must have a valid IP address which is in the range used by the switches default 10 xxx xxx xxx and mask 255 0 0 0 Please check firewall settings if no devices were found A new rule must be created...

Page 7: ...and gateway TIP In the quick configuration it is possible to change the IP address subnet mask and gateway for all devices at one moment More information is explained in the manual for SIMULand v4 10...

Page 8: ...ystem and press the Config button Continue see Remote Management 9 1 4 11 LAN RING v1 Configuration required for properly working Ring before the optical Ring is closed 11 1 1 For the proper functioni...

Page 9: ...be used in one ring together One of the switches connected to the ring must be set as master Master All switches in the ring must be set to the same RING ID 11 1 2 In applications with multiple optic...

Page 10: ...witches in the ring must be allowed the same protocol LAN RING v1 and v2 can not be used in a one ring protocol together 12 1 1 For the proper functioning of the ring all switches must be connected to...

Page 11: ...the same RING ID 12 1 2 In applications with multiple optical rings each ring switches connected in a ring must have a unique RING ID Ring Identifier see menu RING 13 RSTP 13 1 1 For the proper funct...

Page 12: ...tion of Optical Ring Failure or Sabotage In the case of a ring interruption in tin topology LAN RING v1 or v2 failure or sabotage the communication is redirected in 30ms The change of ring state from...

Reviews: