background image

metasoft

PHONE CALL RECORDER

FonTel

Installation manual

Applies to the recorders: 

FonTel L1USB

FonTel L2USB

FonTel L4USB

FonTel ISDN

FonTel L4NET

FonTel VoIP

(last updated: 1-07-2013)

C

METASOFT s.c.

ul. Saperów 21/1A

53-151 Wrocław, Poland

phone: +48 71 350 05 23

fax: +48 71 350 05 96

www.

 

 fontel.eu

 

 

info@

 

 fontel.eu

 

 

Summary of Contents for FonTel ISDN

Page 1: ...nual Applies to the recorders FonTel L1USB FonTel L2USB FonTel L4USB FonTel ISDN FonTel L4NET FonTel VoIP last updated 1 07 2013 C METASOFT s c ul Saperów 21 1A 53 151 Wrocław Poland phone 48 71 350 05 23 fax 48 71 350 05 96 www fontel eu info fontel eu ...

Page 2: ... c company The Metasoft s c company reserves the right to change some details of this product without notice The information contained in this document has been created with highest care yet the Metasoft s c company shall not be liable for its use The trademarks are property of their respective trademark owners and have been used only for information purposes Copyright Metasoft s c Page 2 www font...

Page 3: ...ments 4 1 3 Contents of the package 4 2 Installation 5 2 1 Drivers and software installation 5 2 2 Installing FonTel L1USB L2USB L4USB recorder 8 2 3 Installing FonTel ISDN recorder 9 2 4 Installing FonTel L4NET recorder 10 2 5 Installing FonTel VoIP recorder 11 3 Declarations of conformity 12 Copyright Metasoft s c Page 3 www fontel eu ...

Page 4: ...SK DTMF yes FSK DTMF yes yes FSK yes 1 2 PC Hardware and system requirements sound card USB 1 1 or 2 0 port available LxUSB ISDN Ethernet connection L4NET Windows 2000 XP Vista 7 Sever 8 DirectX 8 0 or higher if Windows 2000 is used 1 3 Contents of the package FonTel phone call recorder installation manual software CD phone cable RJ11 1 2 or 4 pieces LxUSB L4NET phone cable RJ45 ISDN USB A B cable...

Page 5: ...files of the DirectX libraries are located on the attached installation CD Proper DirectX library should be already installed under Windows XP and no update should be necessary To install the recorder and its software please follow below steps In case of L4NET recorder start from step E A Insert FonTel installation disk into CD drive B Plug one and only one of FonTel recorders into PC USB port or ...

Page 6: ...c location Advanced 2 Next 1 Search the best driver in these location 2 Search removable media uncheck Include this location in the search 3 Next 1 Choose Rejestrator Rozmów Telefonicznych FonTel version 2 0 0 0 2 Next Copyright Metasoft s c Page 6 www fontel eu ...

Page 7: ... If installation has not started automatically then run FonTelNNNInstall exe from installation CD NNN is the application version number E Run FonTel application and configure it by the first run a FonTel configuration wizard will guide you through the configuration process F Connect telephone cables appropriately to particular recorder model guidelines look below Copyright Metasoft s c Page 7 www ...

Page 8: ...a simultaneous connection of the recorder and the phone to the same line a regular phone one plug and double output splitter can be used The plug is placed in the phone socket and the splitter sockets are connected to the recorder cable and the phone cable respectively example of the recorder s connection through a phone splitter to a phone line that terminates with a single phone socket Copyright...

Page 9: ... connected to the recorder s TE socket The recorder s NT and TE sockets are internally connected they can be used alternatively PLEASE NOTE The ISDN recorder does not record calls for analog phones connected to NT1 network terminator via an a b interface If necessary replace the analog phones with ISDN phones or use FonTel LxUSB for analog recording Example diagram of the ISDN recorder connection ...

Page 10: ...us connection of the recorder and the phone to the same line a regular phone one plug and double output splitter can be used The plug is placed in the phone socket and the splitter sockets are connected to the recorder cable and the phone cable respectively example of the recorder s connection through a phone splitter to a phone line that terminates with a single phone socket The recorder to the P...

Page 11: ...FonTel installation s manual 2 5 Installing FonTel VoIP recorder Copyright Metasoft s c Page 11 www fontel eu ...

Page 12: ...000 4 4 2004 EN 61000 4 6 1996 A1 2001 Date Place of Issue Name and signature 1 june 2008 Wrocław Poland m sc Przemysław Jodkowski C Declaration of conformity Product FonTel L2USB Product description analog phone call recorder Metasoft s c ul Saperów 21 1A Wrocław Poland declares as a producer that the product fulfills the essential requirements of Directive 1999 5 EC The following harmonized stan...

Page 13: ...ntial requirements of Directive 1999 5 EC The following harmonized standards were applied PN EN 55024 2000 PN EN 55022 2006 A1 2008 Others standards applied PN EN 61000 4 2 2009 PN EN 61000 4 3 2007 A1 2008 PN EN 61000 4 4 2010 PN EN 61000 4 5 2010 PN EN 61000 4 6 2009 PN EN 61000 4 11 2007 PN EN 55016 2 3 2007 Date Place of Issue Name and signature 1 march 2011 Wrocław Poland m sc Przemysław Jodk...

Page 14: ......

Page 15: ......

Page 16: ......

Reviews: